Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
WARNING! It is the user's responsibility to read, understand and abide by the following safety instructions.
1.1.
PERSONAL PRECAUTIONS
 When using this meter, please observe all normal safety rules concerning:
Protection against the dangers of electric current.
Protection of the meter against misuse.
 Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with
genuine Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.
 DO NOT use leads if damaged or if the wire is bared in any way.
1.2.
GENERAL SAFETY INSTRUCTIONS
 Familiarise yourself with the applications, limitations and hazards of the meter. IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.
 Before using the meter inspect the case. If you suspect any part of the case to be damaged or missing DO NOT USe THe MeTeR.
Remove it from service immediately and contact your local Sealey dealer for advice/repairs.
 When the meter is linked to a measurement circuit, do not touch unused meter terminals.
 When the scale of the value to be measured is unknown set the selector to the highest range available.
 Before rotating the rotary switch to change functions, disconnect test leads from the circuit under test.
 WARNING! Never perform resistance measurements on live circuits.
 Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe guards while measuring.
 When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -10ºC to 50ºC.
 Never apply voltage or current to the meter that exceeds the specified maximum.
 Should the low battery indicator appear on the lCd display, replace the battery immediately (PP3). A low battery level could cause
the meter to produce inaccurate readings.
 When not in use, store the meter in a safe, dry, cool and childproof location. DO NOT place in the proximity of a powerful source of
electromagnetic radiation.
2.
INTRODUCTION
durable bi-composite case and integral stand suitable for the toughest workshop conditions. large,
hi-contrast lCd display with 21mm high digital read-out. Unique Test lead Connection feature
indicates correct hook-up. Includes data hold feature and low battery display. Supplied with test
probes, crocodile clips and comprehensive manual.
3.
FEATURES
1.
lCd display
2.
data hold button
3.
Rotary switch
4.
Input terminals
5.
Power ON/OFF
6.
Crocodile clips
7.
Probes
3.1. Rotary Switch (fig.1(3))
The rotary switch allows
selection of the various
functions available and of the
settings for each individual
function.
INSTRUCTIONS FOR:
DIGITAL AUTOMOTIVE ANALYSER 8 FUNCTION
MOdel No:
7
Rotary
Switch
Position

dC voltage measurement

AC voltage measurement
dC Current measurement

diode test

Continuity test

Resistance measurement

Automotive ignition dwell testing (degrees)
Automotive engine tach (rotation speed)
testing (x10 rpm)
Original Language Version
TA200
6
Function
Fig 1
TA200
Issue No: 3 - 19/12/11

Advertisement

loading

Summary of Contents for Sealey TA200

  • Page 1: Dc Voltage Measurement

    TA200 MOdel No: Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 Millivolt. 1x10 -3 or 0.001 volts Amperes (amps). The unit of current. mA: Milliamp. 1x10 -3 or 0.001 amperes Test of dwell. Tach x 10 Number of cylinders Caution - high voltage testing TA200 Issue No: 3 - 19/12/11 Original Language Version...
  • Page 3: Operation

    – x = Correct value of resistance Ω If the resistance reading ≥ 0.5 in the short circuit condition, the test leads may be loose or damaged. If damaged, replace immediately with suitable leads from your authorised Sealey dealer. Ω) For high resistance (>1M several seconds may be required to obtain a stable reading and it is recommended that you use short test leads.
  • Page 4 4.7.4. On starting the engine or whilst it is running, test the rotation speed of the engine and read the value displayed. The display is RPM ÷ 10 i.e. the actual rotation speed is obtained by multiplying the displayed value by 10. TA200 Issue No: 3 - 19/12/11 Original Language Version...
  • Page 5: Maintenance

    The TA200 is suitable for testing those sensors with a dC voltage or low frequency signal output. 4.8.2. Connect the dC voltage type MAF sensor in the dC voltage testing fashion (see section 4.1) and set the rotary switch on the meter to 20V dC.
  • Page 6: Environmental Protection

    ONlY dispose of or recycle according to local authority regulations. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme.