Cisco D9040 User And Service Manual page 88

Table of Contents

Advertisement

Message
Description and Remedy
Power supply
Description: Power supply defective or
failure.
external power line broken Remedy:
Check power cable. If persistent, contact
your Cisco technical support center for
repair.
Power-up self-
Description: The internal power-up self-
test failed.
test failed. Remedy: When persistent,
contact your Cisco technical support
center for further assistance.
Regulus
Description: Error detected on the RS-232
connection error.
connection to the Regulus Statistical
Multiplex Controller. Remedy: Check the
RS-232 connection between the Statistical
Multiplex Controller and the encoder.
Consult the manuals for information on
how to interconnect the devices.
SDI input loss.
Description: There is no video source on
the SDI video input. Remedy: Examine
the video input selection in the GUI and
check the video source.
SDI picture sync
Description: SDI picture sync loss. The
loss.
video signal does not comply with the
specifications. Remedy: Examine the
video signal. It may be off-frequency or
the signal is perhaps a composite signal.
Settings file is
Description: No settings changed in the
rejected.
device as the settings file contains
conflicting settings. Remedy: Not
applicable.
Settings updated. Description: The settings have changed
either by a settings file import or by a
change via the PNC. Remedy: Not
applicable.
Statmux interface
Description: An error in the RS-232
RS-232 error.
statmux interface has been detected.
Remedy: Check that the RS-232 cabling is
OK and that the equipment connected to
the RS-232 interface operates as required.
5-14
Service and Maintenance
Severity
Default
alarm
category
Major
B
Critical
A
Major
B
Major
A
Major
B
Information None
Information None
Major
B
4020024 Rev C
Enable
On
On
On
On
On
On
On
On

Advertisement

Table of Contents