Control Port - Panasonic KX-HDV430 Supplement Manual

Hide thumbs Also See for KX-HDV430:
Table of Contents

Advertisement

KX‐HDV430 Software File Version 03.100 or later 
1. 4.3.12 TWAMP Settings
Add the TWAMP Settings to the [Network] tab of Web User Interface Programming.
Add the following web settings to the TWAMP settings.
Enable TWAMP
Description
Value Range
Default Value
Configuration File Reference

Control Port

Description
Value Range
Default Value
Configuration File Reference
Test Port
Description
Value Range
Default Value
Configuration File Reference
Wait Time for Control
Description
Value Range
Default Value
Configuration File Reference
Wait Time for Reflector
Description
Value Range
Default Value
Configuration File Reference
Selects whether to enable the TWAMP server function.
・Yes
・No
No
TWAMP_ENABLE
Specifies the port for the TWAMP control session.
1-65535
862
TWAMP_CONTROL_PORT
Specifies the port for the TWAMP test session.
1-65535
9000
TWAMP_TEST_PORT
Specifies the time, in seconds, for the TWAMP server to wait for incoming
packets for maintaining the session.
1-65535
900
TWAMP_SERVER_WAIT_TIME
Specifies the time, in seconds, for the TWAMP reflector to wait for incoming
packets for maintaining the session.
1-65535
900
TWAMP_REFLECTOR_WAIT_TIME