Haier HCW225LAES Installation Instructions Manual page 11

24" built-in oven
Hide thumbs Also See for HCW225LAES:
Table of Contents

Advertisement

Available languages

Available languages

1. Disconnect power before servicing.
2. Connect the 2 black wires
3. Connect the 2 neutral (white) wires
(of the oven cable) using a UL listed wire connector.
4. Connect the 2 red wires
5. Install junction box cover.
4-WIRE CONNECTION (UNGROUNDED NEUTRAL)
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations (1996
NEC), mobile homes and recreational vehicles, new construction and in Canada.
Ungrounded Neutral
a
Junction Box
b
Black Wires
c
Red Wires
d
Cable from Oven
1. Disconnect power before servicing.
2. Connect the 2 black wires
3. Connect the 2 red wires
4. Connect the 2 neutral (white) wires
connector.
5. Connect the ground (green or bare) wire
(green or bare) wire (in the junction box) using a UL listed wire connector.
6. Install junction box cover.
b
together using a UL listed wire connector.
c
g
together using a UL listed wire connector.
a
b
c
d
e
UL listed or CSA
Approved Conduit
Connector
f
Ground (Green or
Bare) Wires
b
together using a UL listed wire connector.
c
together using a UL listed wire connector.
h
and the ground (green or bare) wire
i
h
g
f
e
g
UL Listed Wire
Connector
h
Neutral (White) Wires
i
House Electrical Supply
together using a UL listed wire
f
from the oven cable to the ground
d
9