Download Print this page

Yamaha tx7 Service Manual page 4

Fm tone generator
Hide thumbs Also See for tx7:

Advertisement

TX7
5.
Cassette
mode
In this
mode, you
may
store
32
voice
and 32
TX
function
data, or
32
voice
and
32
DX
function data
onto
a cassette.
Or,
you
may
load
this
data
from
the
cassette.
1)
Save
Saving
data
onto
a
cassette.
Press
SAVE/
VERIFY
while
in
shift
mode.
®
To
keep
track of data stored
on
a
cassette, assign
an
index
number
to
the
data.
When
loading,
the
TX7
will
display
this
number.
[
SAVE
NUMBERl—
J
.
...
Use
the
[+1]
[-1]
switches to
"t
select a
number
0
~
1
27.
Save
number
(D
Select
the function data
you want
to
save.
1
SAVE
FUNC?i-_—
... Select using
1+1], [-1]
switches.
INTor
EXT
1
2
VOICE
MEMORY
32]
£
1
>2
TX FUNCTION
MEMORY
32j
1:2
DX
FUNCTION
MEMORY
1
~32|
TNT"
Save
32
voice data
and 32
TX
function
data.
•This
is
automatically
selected
when power
is
turned
ON.
"EXT"
Save
32
voice data
and
32
DX
function
data.
(3)
Execute
save
[SAVE TAPE?
TX
*
U-.1
.
...
To
save,
press [+1]
.
4
Save
number
[
NOW
WORKING!!
1
.
.
.
.
This
will
take
about
45
seconds.
4
If
you want
to abort, press
[—
1
]
.
[
FINISHED!!!
|
.
.
.
.
Save completed.
•Attenuation
function
data
will
not
be saved
on
tape.
Saving the
DX7
data together with the
TX7
data
as a
performance.
1
.
Set
(SAVE
FUNCj
to
INT
and
save.
(Save the
TX7
data
as
in
steps
(f)
~
(D
.
[TAPE
1
}
.}
2.
Turn
the
TX7 memory
protect
OFF.
3.
Send 32
DX7
voice
data
to the
TX7.
(MIDI
TRANS-
MIT)
The 32
TX7
voice
memories
now
hold the
DX7
voices.
4.
The
TX7
will
display
"MIDI
RECEIVED".
5.
Change
to
["SAVE
NUMBERj
to distinguish
between
DX7
and
TX7
data.
6.
Set
["SAVE
FUNCj
to
EXT
and
save.
(Save the
DX7
data
as in
steps (T)
~
(D
[TAPE
2]
)
-
1
TX-x
TX-y
32
VOICE
DATA
I
32 (DX7)
VOICE
DATA
32
TX FUNCTION
DATA
32
DX FUNCTION
DATA
2)
Verify
-Checking
to
see
if
data has
been
correctly
saved. Press
SAVE/VERIFY
after
saving data.
rvER7FY
_
CASSETTE?
|
.
.
.
4
Press
[
+
1]
.
["NOW WORKING"!!
].
.
.
4
|
FOUND
TX
*
,
.
j
1
Play
the
tape.
If
you want
to
quit,
press
[-1]
.
j
Save
number
|
FINISHED!*!
I
Tape
data
is
OK.
If
there
is
a
problem
TAPE
ERRORj
will
be displayed.
3)
Protect
-Protect
memory.
Press
LOAD/PROTECT.
®
Turn
off
memory
protect.
When
loading
from
a
cassette,
receiving
32
voice
and 64 performance
data
via
MIDI,
or
storing
to
memory,
protect
must
be turned
OFF.
When
the
power
is
turned
ON,
memory
protect
will
be
ON.
|
MEM
PROTECT ON
j
....
To
turn
memory
protect
OFF,
l
press
[-1]
.
OFF
4)
Load
Load
data
from
tape. Press
LOAD/PROTECT.
®
Select
the function data
you want
to
load.
[
LOAD
FUNC?-
^
-1
Select usino
!
+
l
1
f
ll
switches
INT
or
EXT
Load 32
TX7
voice
data
and 32
TX7
1
2
VOICE
MEMORY
32
h-
1
NT
function
data.
CVT
Load
32TX7
voice
"
data
and 32
DX7
function
data.
1
2
TX FUNCTION
32
1
2
DX FUNCTION
32
(2)
Execute
load.
I
LOAD
CASSETTE?
j
....
To
begin
ioad, press
[
+
1
]
.
4
j
NOW
WORKING!!
]
....
If
you want
to abort, press
(—1
]
4
.
Data
has
been found.
Save
number
1
FINISHED!!!
_J.
.
.
.
Finished
loading.
*|f
you attempt
to laod
while
memory
protect
is
ON,
^MEMO-
RY
PROTECT]
will
be
displayed,
and you
will
not be
able
to
load.
6.
Store
mode
In this
mode
you
may
store data
from
the
edit
buffers into
memory.
1)
Store
TX
performance
-
Store voice
and
TX
function
data
in
the buffers into the
voice
memory
and
TX
func-
tion
memory
you
select.
Press
TX
PERF.
®
Selecting the
memory
number
to
store
into.
STR TX PERF?
Memory
number
.
Select
the
memory
number
using
the
[TX PERF)
switch.
•Set
memory
protect
OFF.
To
store,
press
[
+
1]
i
FINISHED!!"!
|
...
Voice
and
TX
function data has
"
been
saved
into
the
memory
number you
selected.
The
TX7
stores voice
and
function data
as
a pair.
You
cannot
save only
one
or
the other.
2)
Store
DX
function
- •
Store the function data
in
the
edit
buffer into the
DX
function
memory
you
select.
Press
DX
FUNC.
(T)
Selecting the
memory
number
to store
into.
|
STR DX5
FUNC'^j!
.
.
.
Memory
number
.
Select
the
memory
number
using
the
[DX
FUNC)
switch.
•Set
memory
protect
OFF.
To
store,
press [+1]
|
FINISHED!!!
|.
.
.
.
Function
data has
been
saved
into
the
DX
function
memory
you
selected.
7.
MIDI
mode
In
this
mode, you
may
set
the
conditions
for
MIDI
data
reception
(MODE),
and
transmit
or
initialize
voice data
(DUMP/INIT).
1)
Setting
TX7
MIDI
reception
condition
-
Press
(MODE).
(T)
Control change
reception
[
CTL.
CHNG.
RECl_J
Select using [+1]
[-1]
.
ON
or
OFF
"ON"
The
following control
signals
will
be
received.
Modulation wheel
Breath controller
• Foot
controller
Portamento
time
• Volume
(Not
the
same
as
volume
control
via
the data entry
slider.)
Sustain switch
• Portamento
switch
"OFF"-
••
The
above
control
signals
will
not be
received.
I
'Control change reception
is
memorized.
(2)
Data
entry reception
1
P,
ENTRY
RCV.i__I3]
....
Select using [+1
]
,
[-1
)
.
ON
or
OFF
"ON"
The
following
MIDI
signals
will
be
received,
(when
editing
TX7
voice or
function
data)
Data
entry
Increment
• Decrement
"OFF"--
-
The
above
signals
will
not
be
received.
'Data
entry reception
ON/OFF
is
memorized.
•This switch
and
the data
entry
volume
switch
cannot both
be
ON
at
the
same
time.
When
you
set
the data entry
volume
switch
ON,
this
switch
will
automatically go
OFF.
(D
MIDI
receive
channel.
j
MIDI RCV. CH>
j
1
1
Select using
(+1).
Ml.
MIDI
channel
1
~
16
•The
TX7
MIDI
output channel
is
automatically channel
1.
•The
selected receive
channel
number
is
memorized.
(
4
)
Omni mode
|
OMNI
MODE
i
.
,i
j
Select using
[
+
1]
[-1]
ON
or
OFF
"ON"
The MIDI
receive
channel
setting
will
have
no
effect,
and
MIDI
signals
on
all
channels
will
be
received.
"OFF"--- Only
MIDI
signals
with
the
same
channel
number
as
the
receive
channel
setting
will
be
received.
•Omni mode
ON/OFF
is
memorized.
(§)
Data
entry
volume
i
D.
ENTRY VOL
<1
....
Select using [+1)
[-1]
ON
or
OF
F
"ON"
You may
control the
TX7'$ volume
using the
data entry
slider
on
the
DX7,
DX9
or
DX1
.
"OFF"-
--
The
data entry
slider will
not
affect
the
TX7's
volume.
'Data entry
volume
ON/OFF
is
memorized.
This
switch
and
the data entry
receive
switch
cannot both be
ON
at
the
same
time.
When
you
set
the data
entry
receive
switch
ON,
this
switch
will
automatically go
OFF.
-5-
-
6
-
TX7

Advertisement

loading