INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-18, 24BKS - Series Outdoor unit RAS-18, 24BAS - Series 1115551271 1115551271_(01_EN).indb C1 12/17/15 3:30 PM...
CONTENTS PRECAUTIONS FOR SAFETY ............................... 1 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS ....................2 Optional Installation Parts ................................2 INDOOR UNIT ....................................3 Installation Place ..................................3 Cutting a Hole and Mounting Installation Plate ..........................3 ...
PRECAUTIONS FOR SAFETY PRECAUTIONS FOR SAFETY • Before installation, please read these precautions for safety carefully. • Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below. WARNING : It indicates that incorrect use of this unit may cause severe injury or death. CAUTION : It indicate that incorrect use of this unit may cause personal injury (*1), or property damage (*2).
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS For the rear left and left piping Hook Installation plate Wall Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better operation. Do not allow the drain hose to get slack.
INDOOR UNIT INDOOR UNIT Mounting the installation plate Installation Place Anchor bolt holes • A place which provides the spaces around the indoor unit as shown in the diagram Hook • A place where there are no obstacles near the air inlet and outlet •...
1. Die-cutting front panel slit Wiring Connection Cut out the slit on the leftward or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers.
NOTE Information If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. The lower part of indoor unit may fl oa t , After passing the connecting pipe through the pipe hole, connect the due to the condition of piping and you connecting pipes to the auxiliary pipes and wrap the facing tape around them.
Using a vacuum pump Refrigerant Piping Connection Be sure to use a vacuum pump with counter-fl ow prevention function so that inside oil of the pump does not fl ow backward into pipes of the air Flaring conditioner when the pump stops. (If oil inside of the vacuum pump enters the air conditioner, which use 1.
Electrical Work Model RAS-18BKS RAS-24BKS – 1. The supply voltage must be the same as the rated voltage of the air Maximum running current 12.5A 15.4A conditioner. Plug socket & fuse rating 2. Prepare the power source for exclusive use with the air conditioner. 4 mm (H07RN-F or 60245 IEC66) Power cord...