Mitsubishi Electric FR-PU04 Instruction Manual

Mitsubishi Electric FR-PU04 Instruction Manual

Inverter option unit/parameter unit
Table of Contents

Advertisement

INVERTER
Option unit
FR-PU04
FR-PU04V
INSTRUCTION MANUAL
Parameter unit
FR-PU04
PARAMETER UNIT
STF FWD
PU
PU
EXT
MON
SET
HELP
SHIFT
ESC
7
8
9
4
5
6
FWD
3
1
2
REV
STOP
0
WRITE
READ
RESET
PRE-OPERATION
INSTRUCTIONS
FUNCTIONS
OPERATION
CHECK FIRST WHEN YOU
HAVE A TROUBLE
SPECIFICATIONS
1
2
HELP
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric FR-PU04

  • Page 1 INVERTER Option unit FR-PU04 FR-PU04V INSTRUCTION MANUAL PRE-OPERATION INSTRUCTIONS Parameter unit FUNCTIONS HELP FR-PU04 PARAMETER UNIT STF FWD OPERATION HELP SHIFT CHECK FIRST WHEN YOU HAVE A TROUBLE STOP WRITE READ RESET SPECIFICATIONS...
  • Page 2 Thank you for choosing the Mitsubishi inverter option unit. SAFETY INSTRUCTIONS This instruction manual gives handling information precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please 1. Electric Shock Prevention read this manual carefully to use the equipment to its optimum. WARNING Please forward this manual to the end user.
  • Page 3 A failure to do so may cause some machines to make CAUTION unexpected motions. (3) Usage  Do not install and operate the parameter unit (FR-PU04/PU04V) if it is damaged or has parts missing. WARNING  Do not stand or rest heavy objects on this equipment.
  • Page 4 (5) Disposal CAUTION  Treat as industrial waste. (6) General instruction All illustrations given in this manual may have been drawn with covers or safety guards removed to provide in-depth description. Before starting operation of the product, always return the covers and guards into original positions as specified and operate the equipment in accordance with the manual.
  • Page 5: Table Of Contents

    1.1.1 Unpacking confirmation ..........................3 1.1.2 Appearance and parts identification .......................4 1.1.3 Explanation of keys ............................5 Installation and Removal of FR-PU04/PU04V..................7 1.2.1 Direct installation to the inverter ........................7 1.2.2 Removal from the inverter ..........................8 1.2.3 Installation using the connection cable (FR-CB2) ..................9 1.2.4...
  • Page 6 2.1.3 Setting the power-ON monitor (the first priority monitor) ................16 2.1.4 Using "READ" to change the main monitor ....................17 2.1.5 Using the parameter to change the monitor (Pr. 52) ..................18 Frequency Setting..........................20 2.2.1 Direct setting..............................20 2.2.2 Step setting..............................21 2.2.3 Precautions for frequency setting .........................
  • Page 7 Overview of the Help Menu ......................42 3.1.1 Help menu ..............................42 3.1.2 Help menu transition.............................44 Operation Procedures for the Help Menu..................48 3.2.1 Monitor function ............................48 3.2.2 Selection of PU operation (direct input)......................49 3.2.3 Selection of the PU Jog operation mode ......................50 3.2.4 Parameters ..............................51 3.2.5...
  • Page 8 CHECK FIRST WHEN YOU HAVE A TROUBLE Troubleshooting..........................79 SPECIFICATIONS Standard Specifications ........................80 Outline Drawing and Panel Cutting Drawing.................81 6.2.1 FR-PU04/PU04V outline dimension drawings....................81 6.2.2 FR-PU04/PU04V enclosure cut dimensions....................82 APPENDIX Appendix 1 Disposing of the equipment in the EU countries ..............83...
  • Page 9: Introduction

    INTRODUCTION This product is a unit for setting inverter functions (parameters) and has the following features. · An operation panel can be removed and a parameter unit can be connected. · Setting such as direct input method with a numeric keypad, operation status indication, and help function are usable.
  • Page 10 INTRODUCTION This instruction manual uses the screens on the FR-PU04 connected to the FR-A500 series inverter for describing the operation. For using the FR-PU04V, some indications or terms used in this instruction manual must be replaced as follows. Item FR-PU04...
  • Page 11: Pre-Operation Instructions

    Unpacking and Product Confirmation Take the parameter unit out of the package, check the unit name, and confirm that the product is as you ordered and intact. 1.1.1 Unpacking confirmation Check the enclosed items. FR-PU04/PU04V · Parameter unit ............1...
  • Page 12: Appearance And Parts Identification

    Unpacking and Product Confirmation 1.1.2 Appearance and parts identification Unpack the parameter unit, check the name plate on the back, and make sure that the product has not been damaged before using. FR-PU04/PU04V Monitor section Liquid crystal screen (16 characters 4 lines, ●...
  • Page 13: Explanation Of Keys

    Unpacking and Product Confirmation 1.1.3 Explanation of keys Description · Used to select the parameter setting mode. · Press to select the parameter setting mode. Used to display the first priority screen. Operation cancel key. · Used to display the help menu. ·...
  • Page 14 Unpacking and Product Confirmation Description Forward rotation command key. Reverse rotation command key. · Stop command key. · Used to reset the inverter when a fault occurs. · Used to write a set value in the setting mode. · Used as a clear key in the all parameter clear or alarm history clear mode. ·...
  • Page 15: Installation And Removal Of Fr-Pu04/Pu04V

    (2) Insert the parameter unit straight into the position and fit it securely. FR-PU04 FR-PU04V FR-A500/F500 series inverter FR-V500 series inverter REMARKS · Direct installation of the FR-PU04 is possible only to the FR-A500/F500 series inverter. Direct installation of the FR- PU04V is possible only to the FR-V500 inverter.
  • Page 16: Removal From The Inverter

    Installation and Removal of FR-PU04/PU04V 1.2.2 Removal from the inverter Tilt the parameter unit toward the front while holding down its top button, and pull it out of the hook. FR-PU04 FR-PU04V Hook Hook FR-A500/F500 series inverter FR-V500 series inverter...
  • Page 17: Installation Using The Connection Cable (Fr-Cb2)

    For details of the connection cable (FR-CB2), refer to the instruction manual of the FR-CB2.  Connection to the FR-A500/F500/V500/E500 series inverter (1) Remove the operation panel. (2) Insert the cable plugs into the connectors on the inverter and the parameter unit (FR-PU04/PU04V) until the tabs snap into place. Junction...
  • Page 18: Removal When The Connection Cable (Fr-Cb2) Is Used

    Installation and Removal of FR-PU04/PU04V  Connection to the FR-S500/F500J/C500 series inverter (1) Remove the front cover. (2) Insert the cable plugs into the connectors on the inverter and the parameter unit (FR- Connector PU04/PU04V) until the tabs snap into place.
  • Page 19: Parameters To Be Checked First

    Parameters to be Checked First Parameters to be Checked First Change the following parameter settings as required. For the changing procedures, refer to page 23. 1.3.1 PU display language selection (Pr. 145) By setting the Pr. 145 PU display language selection value, you can select the language displayed on the parameter unit.
  • Page 20: Pu Buzzer Control (Pr. 990)

    Parameters to be Checked First 1.3.2 PU buzzer control (Pr. 990) By setting the Pr. 990 PU buzzer control value, you can select to either generate or mute the "beep" which sounds when you press any of the parameter unit keys. Pr.
  • Page 21: Functions

    FUNCTIONS Monitoring Function 2.1.1 Display overview (2) PU level meter 120.00 (for FR-A500/F500/V500) (1) Main monitor (3) Rotation direction indication (4) Operating status indication (1) Main monitor (3) Rotation direction indication Shows the output frequency (Hz Out), output Display the direction (forward rotation/reverse current (I Out), output voltage (V Out), alarm history rotation) of the start command.
  • Page 22 Monitoring Function (7) Warning indication 120.00 (6) Unit indication (5) Operation mode indicator (5) Operation mode indication (6) Unit indication Displays the status of the operation mode. Shows the unit of the main monitor. EXT: External operation mode PU: PU operation mode (7) Warning indication EXTj: External Jog mode Displays an inverter warning.
  • Page 23: Using "Shift" To Change The Main Monitor

    Monitoring Function 2.1.2 Using to change the main monitor " S H I F T " When "0" (initial value) is set in the Pr. 52 DU/PU main display data selection, simply pressing calls 6 different monitor screens in sequence. Switch power ON or press When output frequency...
  • Page 24: Setting The Power-On Monitor (The First Priority Monitor)

    Monitoring Function 2.1.3 Setting the power-ON monitor (the first priority monitor) Set the monitor which appears first when power is switched ON or is pressed.  When you press during any monitor screen other than ALARM HISTORY being displayed, that screen is set as the power-ON screen and will be displayed first.
  • Page 25: Using "Read" To Change The Main Monitor

    Monitoring Function 2.1.4 Using to change the main monitor " R E A D " Press to display the monitoring list while the main monitor is displayed. Select a monitor from the monitoring list to change the main monitor. Example: Select the output current peak value monitor. The selected monitor is not set as the first priority monitor yet when only was pressed.
  • Page 26: Using The Parameter To Change The Monitor (Pr. 52)

    Monitoring Function 2.1.5 Using the parameter to change the monitor (Pr. 52) To change the third monitor (output voltage monitor), set Pr. 52 DU/PU main display data selection. (Note that setting "17" (load meter), "18" (Motor excitation current), and "24" (Motor load ratio) change the output current monitor.
  • Page 27 Monitoring Function Factory setting * The monitor displayed at powering ON is the first priority monitor. Refer to page 16 for the setting method of the first priority monitor. First priority monitor Second monitor Third monitor 0.00 0.00 0.00 --- STOP EXT --- STOP EXT --- STOP EXT (Output frequency monitor)
  • Page 28: Frequency Setting

    Frequency Setting Frequency Setting The frequency in PU operation mode and External/PU combined operation mode (Pr. 79 = "3") can be set. REMARKS · When changing the operation mode from External operation mode to PU operation mode, operation mode cannot be changed if the external starting signal (STF or STR) is ON.
  • Page 29: Step Setting

    Frequency Setting 2.2.2 Step setting Change frequency continuously using You can change the frequency only while you press . Since the frequency changes slowly at first, this setting can be used for fine adjustment. To cancel an incorrect entry and restore the previous Press Freq Set screen, press...
  • Page 30: Precautions For Frequency Setting

    Frequency Setting 2.2.3 Precautions for frequency setting 1) Pr. 79 Operation mode selection must have been set to switch to the PU operation. (Refer to the inverter instruction manual for details of Pr. 79 .) 2) In the monitor mode, you cannot make the direct setting (Refer to page 20) to set the running frequency. Perform the step setting (Refer to page 21) and press , or press to display the frequency setting...
  • Page 31: Setting And Changing The Parameter Values

    Setting and Changing the Parameter Values Setting and Changing the Parameter Values Using the FR-PU04/PU04V allows you to read the parameter of inverter or change the set value easily. Refer to the inverter instruction manual for details of the parameters.
  • Page 32: Selecting The Parameter From Functional List To Change The Set Value

    Setting and Changing the Parameter Values 2.3.2 Selecting the parameter from functional list to change the set value Example: When changing 5s to 180s at the Pr. 8 Press Deceleration time setting 1 Accl/Decl T A function list regarding 2 Accl/Decl P 3 Brake Seq acceleration/deceleration is Press...
  • Page 33 Setting and Changing the Parameter Values (1) Direct setting Press Enter the desired value. 8 Dec.T1 5.0S 180S (2)Step setting 0~3600 Press Display "180" using Press 8 Dec.T1 180.0S 180.0S The set value is changed. Completed Press to display the next parameter. is pressed when an incorrect setting value is input, the display returns to the list display "8".
  • Page 34: Selecting The Parameter From Parameter List To Change The Set Value

    Setting and Changing the Parameter Values 2.3.3 Selecting the parameter from parameter list to change the set value Example: When changing 5s to 180s at the Pr. 8 Select the parameter. Deceleration time setting When moving the cursor 8 Dec.T1 5.0S using and pressing...
  • Page 35: Selecting The Parameter From User List To Change The Set Value

    Setting and Changing the Parameter Values 2.3.4 Selecting the parameter from User List to change the set value If a parameter is registered to User List, the parameter can be read from User List and changed. (For registering the user group, refer to page 29 .) Example: When changing 5s to 180s at the Pr.
  • Page 36: Precautions For Setting Write

    Setting and Changing the Parameter Values 2.3.5 Precautions for setting write · Perform parameter setting change during an inverter stop basically in the PU operation mode or combined operation mode. The parameter setting cannot be changed in the External operation mode or during inverter operation.
  • Page 37: User Group Function

    User Group Function User Group Function · User group function is a function to display only parameters necessary for setting. · Among all parameters, maximum 16 parameters can be registered to the user group. When "1" is set in Pr. 160, only parameters registered in the user group can be accessed for reading and writing. (The parameters not registered to the user group cannot be read.) REMARKS ·...
  • Page 38: Registering The Parameters To User Group

    User Group Function 2.4.1 Registering the parameters to user group Register. Press SETTING MODE When moving the cursor to "YES" and pressing 0~9:Ser Pr.NO. The parameter unit is in the , the registration is executed. parameter setting mode. Select Oper The parameter setting Read the parameters.
  • Page 39: Deleting The Parameters From User Group

    User Group Function 2.4.2 Deleting the parameters from To continue deleting 1 Max.F1 user group parameter, repeat the 2 Min.F1 operation from step 3. 7 Acc.T1 8 Dec.T1 Press SETTING MODE 0~9:Ser Pr.NO. 2.4.3 Confirming the parameters The parameter unit is in the parameter setting mode.
  • Page 40: Calibration Of The Meter (Frequency Meter)

    Calibration of the Meter (Frequency Meter) Calibration of the Meter (Frequency Meter) The functions vary with the inverter. (Refer to the inverter instruction manual for details of the parameters.) 2.5.1 Calibration of the FM terminal Parameter Enter Pr. 900 FM terminal calibration 900 FM Tune press Pr.
  • Page 41: Calibration Of The Am Terminal

    Calibration of the Meter (Frequency Meter) 2.5.2 Calibration of the AM terminal Press 900 FM Tune Completed Parameter Calibration is complete. <MONITOR> Pr. 901 AM terminal calibration Pr. 158 AM terminal function selection Press to return to the Pr. 55 Frequency monitoring reference main monitor screen.
  • Page 42 Calibration of the Meter (Frequency Meter) (2) When calibrating output current Enter and press For the output current or another item, which does 901 AM Tune Run Inverter not easily point 100% value during operation, 60Hz adjust the reference voltage output, then select the 60Hz is set.
  • Page 43 Calibration of the Meter (Frequency Meter) Press Enter SETTING MODE 0~9:Ser Pr.NO. 901 AM Tune The parameter unit is in the press Run Inverter parameter setting mode. Select Oper 0.00Hz The present Pr. 901 setting appears. Enter 158 AM set Enter and press press...
  • Page 44: Adjustment Of The Frequency Setting Signals "Bias" And "Gain

    Adjustment of the Frequency Setting Signals "Bias" and "Gain" Adjustment of the Frequency Setting Signals "Bias" and "Gain" The functions vary with the inverter model. (Refer to the inverter instruction manual for details of the functions.) 2.6.1 Adjustment procedure There are three ways to adjust the bias and gain of the frequency setting voltage (current). (1) Adjust only the bias and gain frequencies and not adjust the voltage (current) (Refer to page 36) (2) Adjust any point by applying a voltage across terminals 2-5 (starting a current across terminals 4-5) (Refer to page 38)
  • Page 45 Adjustment of the Frequency Setting Signals "Bias" and "Gain" Enter Press 902 Ext2bias 10Hz Voltage need not be applied The bias frequency is set at Set<WRITE> across terminals 2-5. 50Hz. At this time, set the gain on Press the assumption that the 5V 903 Ext2gain (10V) in the inverter is the set The bias frequency is set at...
  • Page 46 Adjustment of the Frequency Setting Signals "Bias" and "Gain" (2) Adjust any point by application of voltage to Enter across terminals 2-5 Set the bias frequency at  Setting of the frequency setting voltage bias 10Hz. 902 Ext2bias 10.00Hz 0.5% Press Freq Set 20.0%...
  • Page 47 Adjustment of the Frequency Setting Signals "Bias" and "Gain"  Setting of the frequency setting voltage gain Press Press , then 903 Ext2gain The gain frequency is set at 60.00Hz 50Hz for 5V input. The present Pr. 903 setting 97.1% 903 Ext2gain Setting is completed as appears.
  • Page 48 Adjustment of the Frequency Setting Signals "Bias" and "Gain" (3) Adjust any point without application of voltage Enter 902 Ext2bias to across terminals 2-5 10Hz Set the bias frequency at  Setting of the frequency setting voltage bias 0.5% 10Hz. -0.5% Press Freq Set...
  • Page 49 Adjustment of the Frequency Setting Signals "Bias" and "Gain"  Setting of the frequency setting voltage gain Press Press , then The gain frequency is set at 903 Ext2gain 60.00Hz 50Hz. The present Pr. 903 setting 97.1% Setting is completed as value appears.
  • Page 50: Overview Of The Help Menu

    HELP Overview of the Help Menu Press key in any operation mode to call the help menu. Various functions can be executed from the help menu. Hold down and press to shift one screen. Menu screen page 1 Menu screen page 2 Menu screen page 3 1 MONITOR 5 Alarm Hist...
  • Page 51 Overview of the Help Menu Help Menu Description Refer To The parameter clear menu appears, and you can perform "parameter clear" and "all 4. Pr.Clear Page 54 clear". 5. Alarm Hist Page 56 This function displays history of past eight faults (alarms). 6.
  • Page 52: Help Menu Transition

    Overview of the Help Menu 3.1.2 Help menu transition 1 MONITOR Output frequency [Hz] 1 Frequency 2 PU Oper Output current [A] 2 Current Output voltage [V] 3 Voltage Fault description * The latest 8 faults are displayed 4 Alarm His Frequency setting (shows the frequency already set)[Hz] 5 F Command Running speed (shows the motor speed or moving speed)[r]...
  • Page 53 Overview of the Help Menu 1 Setting Mode SETTING MODE 1 Appl.Grp 2 Pr.List 0~9:Ser Pr.No. 2 Pr.List 3 User List 3 Set Pr.List 4 Def.Pr.List Select Oper 4 Param Copy 0 Trq Bst1 0 Trq Bst1 6.0% 1 Max.F1 2 Min.F1 3 Pr.List 0~30...
  • Page 54 Overview of the Help Menu INV.RESET Exec<WRITE> Cancel<ESC> [Estimated cause] 1 M.Not Run M.NOT RUNNING 2 M.Spd Error NO I/P Power 3 M.A/Dec Err or Phase Loss 4 M.Curr.High INV.Output V/f Setting 0.00Hz Error? 0.00A 0.0V See Pr.3,14, <SHIFT> 19,47,113 7 INV.Reset 8 T/Shooting 9 S/W...
  • Page 55 Overview of the Help Menu Settings of Pr. 180 to Pr. 196 are displayed. Terminal Name <option> OP1: ---- OP2: ---- OP3: A5NC Param Copy Name:000 Copy area 1 Overwrite area 1 :Select Char Copy area 2 10 Selectop READ:Decide Char WRITE:Executing Reading Copy area 3...
  • Page 56: Operation Procedures For The Help Menu

    Operation Procedures for the Help Menu Operation Procedures for the Help Menu 3.2.1 Monitor function The monitoring list appears and you can change from one monitor screen to another and set the first priority screen. Press Press The help menu appears. I Out The monitor screen selected READ:List...
  • Page 57: Selection Of Pu Operation (Direct Input)

    Operation Procedures for the Help Menu 3.2.2 Selection of PU operation (direct input) You can select the PU operation mode to set PU operation frequency. Enter the set frequency Press 1 MONITOR using and press 2 PU Oper The help menu appears. Freq Set 3 Pr.List 60.00Hz...
  • Page 58: Selection Of The Pu Jog Operation Mode

    Operation Procedures for the Help Menu 3.2.3 Selection of the PU Jog operation mode You can select the PU Jog operation mode to set PU jog frequency. Enter the set frequency Press 1 MONITOR using and press 2 PU Oper The help menu appears.
  • Page 59: Parameters

    You can select the parameter from the list to read and write the parameter setting. Displays the list of user's settings for initial value (settings of the parameters selected with Def. Pr. List 2 * Pr. 199 User's initial value setting). * This function is supported by the FR-PU04 only.
  • Page 60 Operation Procedures for the Help Menu (1) Setting Mode Using , move the 1 Setting Mode 2 Pr.List Press cursor to "2 Pr. List". 1 MONITOR 3 Set Pr.List 2 PU Oper 4 Def.Pr.List The help menu appears. 3 Pr.List 4 Pr.Clear Press Using...
  • Page 61 Operation Procedures for the Help Menu (3) Set Pr.List (4) Def.Pr.List/Def. Pr. List 2 The initial values of parameters are displayed. Call the parameter menu 1 Setting Mode similarly to steps 1 to 3 of Call the parameter menu 2 Pr.List 1 Setting Mode page 52.
  • Page 62: Parameter Clear

    Operation Procedures for the Help Menu 3.2.5 Parameter clear You can perform the "parameter clear" and "all parameter clear". Switch to the PU operation mode before performing any operation. Clear Pr......Returns (initializes) the parameters to the factory settings with the exception of ...
  • Page 63 Operation Procedures for the Help Menu (2) All parameter clear Call the parameter menu 1 Clear Pr. similarly to steps 1 to 3 of 2 Clear All page 54. Select the "Clear All". 1 Clear Pr. , move the Using 2 Clear All cursor to "2 Clear All"...
  • Page 64: Alarm History

    Operation Procedures for the Help Menu 3.2.6 Alarm history Shows the history of past eight faults. Press when displaying Press 1 MONITOR 2 PU Oper the operation mode for fault The help menu appears. 2nd Prev.ERR 3 Pr.List occurrence in steps 4 and 5 4 Pr.Clear PU Leave Out to display the operation data...
  • Page 65: Alarm Clear

    Operation Procedures for the Help Menu 3.2.7 Alarm clear Clears all the fault history. Press 1 MONITOR 2 PU Oper The help menu appears. 3 Pr.List 4 Pr.Clear Using , move the 5 Alarm His cursor to "6 AlarmClear". 6 AlarmClear 7 INV.Reset Hold down and press...
  • Page 66: Inverter Reset

    Operation Procedures for the Help Menu 3.2.8 Inverter reset Resets the inverter. REMARKS Press 1 MONITOR · If the inverter's protective function is activated to 2 PU Oper The help menu appears. bring the inverter to trip (output shutoff), execute the 3 Pr.List 4 Pr.Clear inverter reset only by pressing...
  • Page 67: Troubleshooting

    Operation Procedures for the Help Menu 3.2.9 Troubleshooting If the inverter appears to operate improperly, perform the following operation to display the most likely cause of the fault. This operation may also be performed during inverter operation (PU operation, External operation) or during trip (protection activated).
  • Page 68 Operation Procedures for the Help Menu Troubleshooting guidance 1) M.NOT RUNNING (Motor does not run) M.NOT RUNNING M.NOT RUNNING The protective function is The inverter cannot start because ALARM Max. F1<StartF activated to bring the inverter the inverter starting frequency Indicated Pr.
  • Page 69 Operation Procedures for the Help Menu 2) M.SPEED ERROR 3) M.A/Dec Err (Speed does not match the running frequency (Actual acceleration/deceleration time is longer setting) than the Pr. 7/Pr. 8 setting) M. SPEED ERROR Since the running frequency setting is 5.0S Acceleration time setting <...
  • Page 70 Operation Procedures for the Help Menu 4) M.Curr.High (Inverter output current is larger than normal) Trq. Bst Since the torque boost setting may be First, the running frequency, output current and INV.Output Setting Err? inappropriate, check the following relevant 60.00Hz output voltage of the inverter are displayed.
  • Page 71: Terminal Assignment (Selectop)

    Operation Procedures for the Help Menu 3.2.10 Terminal assignment (Selectop) The signals assigned to the control circuit terminals and their ON-OFF state are displayed. The terminal status of the plug-in option can be checked if a plug-in option FR-A5AX/A5AY/A5AR is installed.
  • Page 72: Option

    Operation Procedures for the Help Menu 3.2.11 Option Displays what options are fitted to the option connectors. Press 1 MONITOR 2 PU Oper The help menu appears. 3 Pr.List 4 Pr.Clear Using , move the 9 S/W cursor to "11 Option". 10 Selectop 11 Option Hold down...
  • Page 73: 3.2.12 Multiple Copies

    CAUTION Turning power OFF during parameter copy (read, write) as below, processing is not completely ended. Perform parameter copy again. · Turn OFF the inverter power. · Remove the FR-PU04/PU04V from the inverter. · Pull out the PU cable.
  • Page 74  Reading the parameter settings of the inverter Give a name. and storing them to FR-PU04/PU04V. You can name each of copy areas 1 to 3. Select the Connect the FR-PU04/PU04V to the copy source Name:012 inverter. :Select Char characters with READ:Decide Char...
  • Page 75 Operation Procedures for the Help Menu  Writing the parameter setting stored in FR-PU04/ Select the "WRITE". PU04V to the inverter Copy area 1 Using , point the 1 Read VFD Connect the FR-PU04/PU04V to the copy destination cursor to "2 Write VFD" and 2 Write VFD inverter.
  • Page 76 · Read and write cannot be stopped during execution. · If power is switched OFF, parameter data stored in the parameter unit remains unerased. (2) Verifying the parameters All the parameter settings stored in the FR-PU04/PU04V are verified with those which are stored in the inverter. REMARKS Verification cannot be performed between different inverter series.
  • Page 77 Operation Procedures for the Help Menu Select the "Verifying". If an error is detected during verification, the Copy area 1 Using , point the corresponding Pr. is shown. 1 Read VFD Param Copy cursor to "3 Verifing" to press 2 Write VFD Note that only "Verify Err"...
  • Page 78: Other Precautions

    Other Precautions Other Precautions 3.3.1 Precautions for parameter unit operation Note the following items when operating the parameter unit to prevent setting from being disabled or incorrect values from being entered. Precautions for the digit count and decimal point of input value The maximum number of input digits is six including a decimal point.
  • Page 79: Operation

    OPERATION How to Select the Operation Mode 4.1.1 Switching from External 4.1.2 Switching from PU operation operation mode [EXT] to PU mode [PU] to External operation operation mode [PU] mode [EXT] Confirmation Confirmation Make sure that the external input signal (STF, STR) is OFF. Make sure that the external input signal (STF, STR) is OFF and that the operation command indication is "- - -".
  • Page 80: Switching To The External / Pu Combined Operation Mode

    How to Select the Operation Mode 4.1.3 Switching to the External / PU combined operation mode Changing the Pr. 79 Operation mode selection setting to "3" or "4" switches to the External / PU combined operation mode. "PU+E" is displayed in the operation mode indication position. 0.00 --- STOP PU+E The relationship between the running frequency and the start signal is as indicated in the following table.
  • Page 81 How to Select the Operation Mode REMARKS If the operation mode cannot be switched properly, check the following: · Make sure that the external input signal is OFF. If it is ON, the operation mode (STF or STR signal) cannot be switched properly.
  • Page 82: How To Operate Pu Operation

    How to Operate PU Operation How to Operate PU Operation 4.2.1 Normal operation During motor operation, the speed can be changed Step Operation Procedure Image by simply executing Step 2. Press 4. Stop Step Operation Procedure Image The motor is decelerated to Switch power ON.
  • Page 83: Pu Jog Operation

    How to Operate PU Operation 4.2.2 PU Jog operation Step Operation Procedure Image Press , then Hold down to perform operation, and The PU Jog operation mode release it to stop. 3. Jog operation mode selection is selected, and the PU Jog Jog operation cannot be performed in the following frequency setting screen cases:...
  • Page 84: Combined Operation (Operation Using External Input Signals And Pu)

    Combined Operation (Operation Using External Input Signals and PU) Combined Operation (Operation Using External Input Signals and PU) 4.3.1 Entering the start signal from outside and setting the running frequency from the PU (Pr. 79 = 3) Step Operation Procedure Image The external frequency setting signals and Set the start switch (STF...
  • Page 85: Entering The Running Frequency From Outside And Making Start And Stop From The Pu (Pr. 79 = 4)

    Combined Operation (Operation Using External Input Signals and PU) 4.3.2 Entering the running frequency from outside and making start and stop from the PU (Pr. 79 = 4) Step Operation Procedure Image Step Operation Procedure Image Switch the power ON. Press of the 1.
  • Page 86: Entering The Start Signal And Multi-Speed Signal From Outside And Setting Multiple Speeds From The Parameter Unit

    Combined Operation (Operation Using External Input Signals and PU) 4.3.3 Entering the start signal and multi-speed signal from outside and setting multiple speeds from the parameter unit Step Operation Procedure Image Step Operation Procedure Image Change the multi-speed Switch the power ON. frequency during 1.
  • Page 87: Check First When You Have A Trouble

    CHECK FIRST WHEN YOU HAVE A TROUBLE Troubleshooting If a fault occurs and the inverter fails to operate properly, locate the cause of the fault and take proper corrective action by referring to the troubleshooting below. If the corresponding information is not found in the table, the inverter has problem, or the component parts are damaged, contact your sales representative.
  • Page 88: Specifications

    SPECIFICATIONS Standard Specifications Specifications Item FR-PU04/PU04V Surrounding air temperature -10C to +50C (non-freezing) *1 Ambient humidity 90%RH or less (non-condensing) Storage temperature -20C to +65C *2 Ambience Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) Maximum 1000m above sea level for standard operation.
  • Page 89: Outline Drawing And Panel Cutting Drawing

    Outline Drawing and Panel Cutting Drawing Outline Drawing and Panel Cutting Drawing 6.2.1 FR-PU04/PU04V outline dimension drawings 15 10.5 5-M3 screw Valid depth 4.5 (Front) (Side) (Rear) (Unit: mm)
  • Page 90: Fr-Pu04/Pu04V Enclosure Cut Dimensions

    Outline Drawing and Panel Cutting Drawing 6.2.2 FR-PU04/PU04V enclosure cut dimensions 16.5 23.75 11.75 5-φ4 hole 1.25 (Unit: mm)
  • Page 91: Appendix

    APPENDIX Appendix 1 Disposing of the equipment in the EU countries • The symbol shown below, which is printed on the product for EU countries, means that electric and electronic equipment, at their end-of-life, should be disposed of separately from your household waste. •...
  • Page 92 MEMO...
  • Page 93 REVISIONS *The manual number is given on the bottom left of the back cover. Print Date *Manual Number Revision Apr. 2016 IB(NA)-0600637ENG-A First edition IB(NA)-0600637ENG-A...
  • Page 94 INVERTER HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN IB(NA)-0600637ENG-A(1604) MEE Printed in Japan Specifications subject to change without notice.