Fujitsu AOYG36LATT Service Manual page 63

Simultaneous operation 2-3 room multi indoor/outdoor units
Hide thumbs Also See for AOYG36LATT:
Table of Contents

Advertisement

INDOOR UNIT
CEILING
ABYG18LVTB
ABYG22LVTA
ABYG24LVTA
2012.06.14
Name and Shape
Cover plate (Left)
Screw (M4 × 10mm)
Bracket
(Left)
For suspending
the indoor unit from ceiling
Special nut
For suspending
the indoor unit from ceiling
Screw (M4 × 20mm)
For fixing the wall bracket
Coupler heat insulator
(Small)
For indoor
side pipe joint (Small pipe)
Cable tie (Small)
For electrical wiring
Drain hose
Insulation
(Drain hose)
Adhesive type 100 x 220(mm)
Remote control
Remote control
holder
Q'ty
Name and Shape
Cover plate (Right)
1
Installation template
2
Positioning for
under ceiling type
Bracket
(Right)
1
For suspending
the indoor unit from ceiling
Wall bracket
4
For suspending
the indoor unit on the wall
Coupler heat insulator
(Large)
6
For indoor
side pipe joint(Large pipe)
Cable tie (Large)
1
For fixing drain hose
Wire clamper
2
For electrical wiring
Hose band
1
For installing
drain hose
VT wire
1
For fixing drain hose
L 280mm
Battery
1
For remote control
Screw (M3 × 12mm)
1
For remote control
holder installation
62
Q'ty
1
1
1
2
1
1
1
1
1
2
2