Page 1
SPLIT-TYPE AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT Basic : AQV12NSAN Model: AQV09UGAN AQV12UGAN Model Code : AQV09UGAN AQV09UGAX AQV12UGAN AQV12UGAX AIR CONDITIONER CONTENTS good' sleep Mode Catechin Filter Silver Nano Evaporator Deodorizing Filter Anti-Bacterial Cross Fan Refer to the service manual in the GSPN(see the rear cover) for the more information.
Page 2
E464 is displayed..............4-18 4-3-14 Comp Rotation error When E467 is displayed................ 4-19 4-3-15 Current sensor error When E468 is displayed................. 4-20 4-3-16 DC-Link voltage sensor error When E469 is displayed............4-21 4-3-17 OTP error When E471 is displayed....................4-22 Samsung Electronics...
........................... 17. Wiring Diagram ..........................18. Schematic Diagram ........................8-1.PCB Circuit Description ........................8-1-1.Indoor Unit..............................8-1-2.Display ................................19. Reference Sheet ..........................9-1 Refrigerating Cycle Diagram ......................9-2 Index for Model Name ........................9-3 Distribution chart of the pressure....................... Samsung Electronics...
Page 5
FRONT.(use + Screw Driver) 4) Loosen connector wire(white) and detach the temperature sensor wire. 5) To detach the FRONT-PANEL the main frame, unfasten 2 screw at the bottom.(use + Screw Driver) 6) Take off the FRONT-PANEL,lifting up the bottom. Samsung Electronics...
Page 6
1) Unfasten the earth screw.(use + Screw Driver) 2) Detach the temperature sensor and Humidity sensor. 3) Detach COVER-CONTROL from the CASE- CONTROL. 4) Loosen MPI connector wire(yellow), and MOTOR wires(white,blue). 5) Take off the CASE-CONTROL from the main frame. Samsung Electronics...
Page 7
Procedure Remark 1) Unfasten the screw. 2) Cut the cable tie. 3) Loosen the terminal block wires. (Total 4EA: #N(T)-2EA, #2-TEA, #3-TEA) Caution: The terminal is locking type. So, when you separate terminals, pull pressing the button. Button Samsung Electronics...
Page 8
6) Loosen the MPI connector(CN81). Option connector. Caution: When you separate the connector, pull pressing the locking button. 7) Loosen the Relay #4 blue-connector(RY71). Caution: The terminal is locking type. So, when you separate terminals, pull pressing the button. Button Samsung Electronics...
Page 9
10) Loosen the Thermistor wire connector(CN43). Caution: When you take off the PBA, don’t touch the components. Please hold the PBA both side. 11) Loosen the Motor connector(CN71). Caution: When you separate the connector, pull pressing the locking button. Samsung Electronics...
Page 10
Operating Instructions and Installation Parts Procedure Remark 12) Take off the main PBA from the ASS’Y Control in. Caution: When you take off the PBA, don’t touch the components. Please hold the PBA both side. Samsung Electronics...
Page 11
1) Unfasten the screw at the right side. (use + Screw Driver) 2) Unfasten the screw at the left side. (use + Screw Driver) 3) Detach the HOLDER PIPE. 4) Take off the EVAPORATOR from the main frame. Samsung Electronics...
Page 12
2) unfasten the 3 points screws in the CASE- CONTROL, and then detach the CASE. (use + Screw Driver) 3) unfasten the screw a little.(use + Screw Driver) 4) Lift up the evaporator slightly and pull the CROSS-FAN to the left side. Samsung Electronics...
Page 13
Cabinet Front lower to detach the Cabinet Front. (Use +Screw Driver.) 3) Detach the Cabinet Front like the picture on the right side. 4) Loosen 1 screw(CCW) fixed to assemble Plate Control Out with Cabinet-Side RH. (Use +Screw Driver.) 3-10 Samsung Electronics...
Page 14
5) Loosen 2 fixing screws(CCW) on the rear side of Cabinet-Side RH. (Use +Screw Driver.) 6) Loosen 3 screws(CCW) fixed to assemble Bracket Valve with Cabinet-Side RH. (Use +Screw Driver.) 7) Loosen 2 fixing screws(CCW) of Cabinet Side LF. (Use +Screw Driver.) Samsung Electronics 3-11...
Page 15
1) Detach the Motor Wire from the PCB of Ass’y Control Out. 2) Detach several connectors from the PCB of Ass’ y Control Out. 3) Detach 2 Connect Wires from Reactor. 4) Loosen 1 screw(CCW) fixed to assemble Ass’y Control Out with Partition. (Use +Screw Driver.) 3-12 Samsung Electronics...
Page 16
2) Detach the Terminal Cover and detach the Connect Comp Wire from Compressor. 3) Disassemble the Felt Comp Sound. 4) Loosen the 3 bolts(CCW) at the bottom of Compressor like the picture on the right side. (Use Monkey Spanner.) Samsung Electronics 3-13...
#8:MPI Display Control 6-1-4. Outdoor Main PCB AQV09UGAX : DB93-07108C AQV12UGAX : DB93-07108D Power N Wire Power L Wire AC FAN Wire Communication Wire 4 Way Valve Wire DIS/OUTDOOR/COND Temperatrue Sensor EEV Connector Download Connector Reactor Wire Compressor Wire Samsung Electronics...
Page 40
Check the distance between the product and the other electronic appliances such as TV, Video, and audio. It should be over 2m. - If not, it causes a bad picture quality or a noise. Repairing the products by consumer should be strictly prohibited. - There is a danger of electric shock or fire due to incorrect disassembly. Samsung Electronics...
- There is a danger of electric shock. In case the product will not be in use for a long time, the battery of remote control should be kept separately. - Leakage of inside fluid can cause break down of remote control. Samsung Electronics...
Silver Nano Evaporator Deodorizing Filter Activated carbon is incorporated in the filter,efficiently absorbing cigarette smoke, pet odors, and other unpleasant smells, replacing them with clean,refreshing air. Mode The Micro Plasma Ion mode creates strong purified zone in your room. Samsung Electronics...
Page 43
2-1-2 Modified items compared with Basic model Modified New contents New model New model part and characteristic AQV09UGA AQV12UGA Indoor Indoor Design changed Outdoor chassis changed Samsung Electronics...
Page 45
Remote Control DB93-07073E Batteries for Remote Control DB47-90024A Indoor Unit User’s Manual DB98-29980A Installation Manual DB98-29786A Drain Plug DB67-20011A Outdoor Unit Rubber Leg DB73-20134A 2-3-2 Filter Image Part name Code no Remark DB63-02143A(Left) Pre-filter wash in water DB63-02144A(right) Samsung Electronics...
9-1 Refrigerating Cycle Diagram Outdoor Unit Indoor Unit ※Note Capillary tube Check valve 2 way valve Liquid side Capillary tube Heat Heat Exchanger Exchanger (Evaporator) (Condenser) Gas side 3 way valve 4 way valve Cooling Heating Compressor Gas Leak Check Point Samsung Electronics...
Every time you push the button, the display panel reads ..repeatedly. Push the button to Push the button to set the display panel to . Every time you push the button, the display panel reads ..repeatedly. Samsung Electronics...
Page 61
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model. Samsung Electronics...
Page 63
- Check the assembling status of Fan connector(CN01) the outdoor PCB - Check the wire color of fan connector When it occur first, it shows Error. Outdoor Fan error Continue 4-3-10 After 10 minutes, it can be operating. Samsung Electronics...
Page 64
- Check the refrigerant of compressor shows Error. capacity miss - Reset remote-control option code Continue 4-3-20 match DC-Link voltage it operates after 3 minutes. under/over error Operation If outside temperature come back within Continue Condition Error the normal range, it operates. Samsung Electronics...
Page 82
Exchange the one of them according to the exact outdoor unit model spec Re-set the option code again at indoor unit Is the capacity miss match error appeared Terminate the service again? Exchange the outdoor unit’s PBA Samsung Electronics 4-23...
Page 83
Is the resistance for the Exchange the OUTDOOR PCB. detection of DC Link voltage normal? Is the resistance value of Exchange the OUTDOOR PCB. DC Link discharge normal? Is the reactor insulation damaged? Exchange the OUTDOOR PCB. Exchange the reactor. 4-24 Samsung Electronics...