Haier HYCD-282 Operation Manual

Haier HYCD-282 Operation Manual

Combined
Hide thumbs Also See for HYCD-282:

Advertisement

Certificate of Quality
checker:
Manufacturer: Haier Medical and Laboratory Products Co., Ltd.
Address: Haier Industry Park, Economic Technology Development
Zone. Qingdao 266510.P.R.China
Web:www.haiermedical.com
Version:1st,2017
Dedicated code:0270501012
V13026
Combined Refrigerator and Freezer

Operation Manual

Read the Operation Manual carefully before using your appliance.
Keep the Operation Manual in a safe place.
Appearance , color and layout of the door may vary.
Translation of the original instruction.
The scope of the product application: The upper scope is fit for pharmaceuticals and
other related products which needs a storage environment of 2~8℃.The lower
scope is fit for low temperature storing goods.
Model:
HYCD-282
HYCD-282A

Advertisement

Table of Contents
loading

Summary of Contents for Haier HYCD-282

  • Page 1: Operation Manual

    Operation Manual Model: HYCD-282 HYCD-282A Certificate of Quality checker: Manufacturer: Haier Medical and Laboratory Products Co., Ltd. Address: Haier Industry Park, Economic Technology Development Zone. Qingdao 266510.P.R.China Web:www.haiermedical.com Read the Operation Manual carefully before using your appliance. Version:1st,2017 Keep the Operation Manual in a safe place.
  • Page 2 Type Designation/Trademark: HYCD-282 Haier HYCD-282A Manufactures Name : Haier Medical and Laboratory Products Co.Ltd. Manufactures Address : Haier Industrial Park, Economic Technology Development Zone. Qingdao 266510.P.R.China Refer to in this declaration confirms with the following directive(s)/standards: 2006/42/EC, EN60335-1, EN60335-2-89 EN62233...
  • Page 3: Product Feature

    Refrigerating chamber and freezing chamber have independent refrigeration control, they can be used individually as needed. I hereby apologize for the inconformity of your Haier pharmaceutical refrigerator with freezer with manual figure due to product improvement. Manual content will change without prior notice.
  • Page 4: Table Of Contents

    Packing List HYCD-282 HYCD-282A Name Manual Defrost shovel Plastic bag Content: Support Infinite partition board Product Feature............Content..............Safety Precautions........... Precautions for Use..........Product Installation ........... Component Names Control Panel......Application method ........... Alarm................ Cleaning and Maintenance........Rechargeable Battery Recycling......
  • Page 5: Safety Precautions

    Safety Precautions Specification Dear users: Specification Thanks for your choice of Haier Combined Refrigerator and Freezer; please make sure you have carefully read and observed the contents with following signs in the manual, for better understanding Combined Refrigerator and Freezer Name of this manual and better use of this product, to prevent personal injuries and goods damage.
  • Page 6 Don't put container with water or heavy stuff on refrigerator-freezer. Or the object may fall Circuit Diagram to injury person, and the water will reduce insulation level to cause electric leakage or electric shock. Refrigerator-freezer should not be grounded through gas pipe, power supply tube, telephone line or lightning rod.
  • Page 7 Refrigeration Schematic & Circuit Diagram Refrigeration schematic diagram (refrigeration) Refrigeration evaporator It needs to examine the setting of refrigerator-freezer when restart it after outage or power off. The change of setting may damage the stored articles. Once the power of refrigerator-freezer is cut off, it needs to wait for 5min before Wire and tube condenser reconnection, or compressor or system may be damaged.
  • Page 8: Precautions For Use

    This chapter will give answers to various possible failures, and solutions. such situation, switch on battery, and the battery will be fully charged after 6 days of continuous If the problem is still not solved after operation, please call Haier after-sales operation of refrigerator-freezer.
  • Page 9: Product Installation

    Product Installation Rechargeable Battery Recycling Install a recyclable charging battery in refrigerator-freezer, and when it is to achieve the service life, Installation environment please contact local battery recycle agent for inspection, or correctly discard the battery. Environment temperature: 16°C to 32°C, the ideal temperature is 18°C to 25°C, and air conditioning system should be used when necessary.
  • Page 10 3 years, it may fail to act in case of alarm, battery should be replaced earlier, and please contacts Trundle can be used to move the cabinet after removing package. Haier after-sales servicer. The inclination angle of cabinet should not be greater than 45° during moving.
  • Page 11 Cleaning and Maintenance Component Cleaning Initial Power-on To prevent electric shock or personnel injury, make sure to cut off Observe the rules below for initial start-up and continuous operation: refrigerator-freezer power before any repair. Be sure not to breath in drug or suspended particle around refrigerator-freezer Under the condition of empty cabinet, connect power wire to special socket with proper during maintenance, or it may affect your health.
  • Page 12 This product is responsible by special person, who will check the operation and record Automatic recovery of alarm every day (Record and check every 2-4h), the temperature in cabinet will rise in case of machine fault or stop, if it can't be repaired in short time, please take out articles and move This series of refrigerator has alarm automatic recovery function: to the places meeting storage temperature requirement, and avoid damage.
  • Page 13: Component Names Control Panel

    Alarm Phenomenon Fault code Indication Buzzer alarm Component Names When the cabinet temperature is higher HYCD-282 High It is set by default Indicator will flash than the setting value temperature that buzzer alarm will of high temperature start 2h after first...
  • Page 14 Alarm After power on, refrigerator-freezer will enter into start status, display screen will show cabinet HYCD-282A temperature. Display panel work status hints: Lock Indicator: Light on means all settings are locked to prevent misoperation. Light switch Alarm indicator lamp: Light on or flashing means failure. Control panel Key function: USB interface...
  • Page 15 U disk data time parameter setting After unlocking, press setting, digit switch, temperature adjustment keys for more than 5s, the first HYCD-282 two digits on refrigerating display screen shows 1P stably, frozen display screen will blinking display year (10 by default), and the year will increase by 1 for each press of temperature adjustment key,...
  • Page 16: Application Method

    Application method Temperature setting The setting temperature by default of cold storage area is 5°C, the frozen area is -40°C; 1. Unlock For non-use setting, the default value is 1, meaning the normal operation of current activated area, When the lock indicator lights, all keys are locked except digits switch key, it should be unlocked 0 means the current activated area is disabled;...

This manual is also suitable for:

Hycd-282a

Table of Contents