Hide thumbs Also See for BVP-E30:
Table of Contents

Advertisement

BVP-E30 Series
Video Camera
System
HDC1000 Series
Video Camera
System
CAMERA NETWORK SYSTEM MANUAL
1st Edition

Advertisement

Table of Contents
loading

Summary of Contents for Sony BVP-E30

  • Page 1 BVP-E30 Series Video Camera System HDC1000 Series Video Camera System CAMERA NETWORK SYSTEM MANUAL 1st Edition...
  • Page 2 ! 警告 このマニュアルは,サービス専用です。 お客様が,このマニュアルに記載された設置や保守,点検,修理などを行うと感電や火災, 人身事故につながることがあります。 危険をさけるため,サービストレーニングを受けた技術者のみご使用ください。 ! WARNING This manual is intended for qualifi ed service personnel only. To reduce the risk of electric shock, fi re or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. Refer all servicing to qualifi...
  • Page 3: Table Of Contents

    Table of Contents Manual Structure 3. Connection Settings of Equipment Purpose of this manual ............2 (E) 3-1. Settings of Camera Network System ......3-1 (E) Trademarks ................2 (E) 3-2. Connection Setting on MSU-900/950 .......3-2 (E) 3-2-1. Network Confi guration Menu ......3-2 (E) 3-2-2.
  • Page 4: Manual Structure

    Manual Structure Purpose of this manual This manual is the LAN connection setup manual of the Sony system camera equip- ment. It contains information on the system confi guration method to control the Sony system camera equipment using the LAN connection.
  • Page 5: Service Overview

    1-1. Camera Network System Overview The Sony system camera equipment is controlled by the unique communication protocol using the CCA-5 cable. The network control system is realized by connecting the equipment via LAN and by expanding this protocol on TCP/IP.
  • Page 6: Applicable Models

    Before connecting equipment to the system, check the version number of the ROM installed in each equipment. If the required versions as specifi ed below are not installed yet, upgrade the version. Contact your local Sony Sales Offi ce/Service Center for version upgrade. Name of equipment...
  • Page 7 MCS mode The MCS mode enables confi guration of the multiple camera systems consisting of the multiple equipment supporting the network connection. The MCS mode is equivalent to the conventional system that uses CNU. Cameras can be selected from the MSU enabling control and the RCP assignment. In the MSU mode, any single MSU among the equipment in the system should be assigned as the Master and be set accordingly.
  • Page 9: System Confi Guration Diagram

    Section 2 System Confi guration Diagram 2-1. Bridge Mode System Confi guration 2-1-1. Example of Connecting CCU/HDCU and Control Panel Connection example using RCP Bridge mode Semi-Auto (Active mode) CCU/HDCU Camera head Bridge mode Fiber cable Triax cable The power to the RCP should be supplied via PoE HUB or to the EXT I/O connector.
  • Page 10: Example Of Connecting Multiple Units

    2-1-3. Example of Connecting Multiple Units Multiple camera systems of the Bridge mode can be mixed on the single network. In the confi guration shown below, how- ever, camera select by MSU or RCP assignment are not possible. Bridge mode Semi-Auto (Active mode) CCU/HDCU Camera head...
  • Page 11: Mcs Mode System Confi Guration

    2-2. MCS Mode System Confi guration 2-2-1. Connection Example Using CCU/HDCU Supporting Network Connection For this connection, select the Legacy mode for the CNS MODE setting of RCP. Because the equipment number (camera number) of CCU/HDCU is used as the camera selection numbers by MSU, the same equipment number (camera number) of CCU/HDCU should not be duplicated.
  • Page 12: Connection Example Using Rcp Supporting Network Connection

    2-2-2. Connection Example Using RCP Supporting Network Connection For this connection, select MCS for the CNS MODE setting of RCP. Because the equipment number of RCP is used as the camera selection numbers by MSU, the same equipment number of RCP should not be duplicated.
  • Page 13: Connection Example Using Ccu/Hdcu And Rcp Supporting Network Connection

    2-2-3. Connection Example Using CCU/HDCU and RCP Supporting Network Connection For CCU/HDCU and RCP, set the numbers that correspond to the camera selection numbers of MSU. The same number should not be duplicated among the multiple units of RCP and CCU/HDCU for secure connection. For the method of setting the equipment numbers, refer to Section “3-3-5.
  • Page 14: Application Example Of System Confi Guration

    2-2-4. Application Example of System Confi guration For CCU/HDCU and RCP, set the numbers that correspond to the camera selection numbers of MSU. The same number should not be duplicated among the multiple units of RCP, CCU/HDCU and MSU for secure connection. For the method of setting the equipment numbers, refer to Section “3-2-2.
  • Page 15: Notes When Confi Guring System

    2-2-5. Notes When Confi guring System Power supply to RCP The power to the RCP-920/921 can be supplied via three methods of “PoE”, “Via CCA-5 cable” and “Supplying power to EXT I/O”. A method of supplying power is automatically selected in the way that the power with the highest voltage has priority.
  • Page 17: Connection Settings Of Equipment

    Section 3 Connection Settings of Equipment 3-1. Settings of Camera Network System Legacy Bridge Mode MCS Mode Active Passive Master Client Mode Select Legacy Bridge Bridge Connection Mode Semi-Auto Semi-Auto (Active) (Passive) Target IP Address IP address of connection target Master/Client Master Client...
  • Page 18: Connection Setting On Msu-900/950

    3-2. Connection Setting on MSU-900/950 Enter the Engineer Mode for setting. For details of the menu operation block, menu operation method and setting method in Engineer Mode, refer to the Opera- tion Manual. 3-2-1. Network Confi guration Menu Menu display method 1.
  • Page 19: Bridge Mode Setting Menu

    3-2-3. Bridge Mode Setting Menu Item Function Bridge mode Set Exit Connection Bridge mode operation setting mode Active : The settings are performed from one’s Engineer Mode own side Passive : Awaits connection from the Target equipment Semi-Auto : Active or Passive are switched Connection mode depending on the connection environment...
  • Page 20: Lan If Setting Menu

    3-2-5. LAN IF Setting Menu Set the equipment when connected to LAN. Implement the following settings in accordance with the connection Target. Item Function Ethernet IF Setting Exit Negotiation When “AUTO” is set, Speed and Duplex are set automatically Engineer Mode When Negotiation is set to “AUTO”...
  • Page 21: Connection Setting On Rcp-920/921

    3-3. Connection Setting on RCP-920/921 Enter the Engineer Mode for setting. For details of the menu operation block, menu operation method and setting method in Engineer Mode, refer to the Opera- tion Manual. 3-3-1. SETTING Menu Menu display method 1. Press the Paint adjustment block [ENTER] button to display the top screen of the Paint menu. 2.
  • Page 22: Lan If Setting Menu

    When the CNS MODE is set to “MCS” < C N S S E T T I N G > S E T Item Function C N S M O D E : M C S Display of the Master/Client setting in the system M / C : C L I E N T (Fixed to CLIENT)
  • Page 23: Rcp No. Setting Menu

    3-3-5. RCP No. Setting Menu < R C P N o . S E T > Item Function > R C P N o . : RCP No. Set equipment number of RCP In the MCS mode, set the numbers so that they should not duplicate among the multiple units of RCP within the same system.
  • Page 24: Connection Setting On Hdcu1000/1080/1500/3300 And Ccu-590/790

    3-4. Connection Setting on HDCU1000/1080/1500/3300 and CCU-590/790 Implement the NETWORK setting of the CCU-MENU. For details of the menu operation block and menu operation method, refer to the Operation Manual. . When implementing the network setting, it can be effi ciently set by using the CCU Menu Control menu of the RCP that is directly connected to the CCU/HDCU with the CCA cable.
  • Page 25: Lan If Setting Menu

    3-4-3. LAN IF Setting Menu Set the equipment when connected to LAN. Implement the following settings in accordance with the connection Target. < E T H E R I / F C O N F > N 0 1 T O P Item Function AUTO...
  • Page 26: Equipment Setting

    3-4-6. Equipment Setting In addition to the menu setting items, the equipment setting should also be performed. Setting the equipment number (camera number) When equipment is used in the MCS mode, the equipment number (camera number) should be set. In the CNU system, the CCU/HDCU connector numbers become the equipment number. However, in the Camera Network System, the equipment number should be set to the individual equipment separately.
  • Page 27 Communication method setting Select enable/disable of network connection. The setting switches of the respective models are shown below. . CCU-590/790 : When the switch SW5 of S310 (B-4/side A) of the AT-155 board is set to ON, connection setting on the network becomes possible.
  • Page 29: Rcp Assignment

    Section 4 RCP Assignment 4-1. RCP Assignment Function Overview The RCP assignment is the function that enables us to change combination of camera and CCU/HDCU from RCP without changing the physical connection of the control cable. The RCP assignment function can be used in the MCS mode. (This function can be set from the MSU that is set as Master, and cannot be set from the MSU that is set as Client.) For example, the RCP-1 that is connected to the CCU/HDCU-1 in the following fi...
  • Page 30: Setting Method

    4-2. Setting Method The RCP assignment function is set from the MSU that becomes Master. Press the menu operation block [CONFIG] button to display the RCP assignment menu. For details of the menu operation block and menu operation method, refer to the Operation Manual. RCP Assignment Exit Panel No.
  • Page 31: Preview

    Section 5 Preview 5-1. Preview Function Overview The RCP of the Joystick (lever) type has the Preview switch. ON/OFF status of the Preview switch can be obtained from the interface connector. This signal can be obtained from the RCP. However, linking the signal to the assigned CCU/HDCU number becomes diffi...
  • Page 32: Setting Method At Ccu/Hdcu

    5-3. Setting Method at CCU/HDCU HDCU1000/1080/1500/3300 Use the CCU Confi guration menu to display the I/F SETUP. < I / F S E T U P > C 0 4 T O P Item Function REAR PREVIEW Select the operation mode of the REAR B O A R D F R O N T R E A R...
  • Page 34 BVP-E30 (SY) BVP-E30P (SY) BVP-E30WS (SY) BVP-E30WSP (SY) CCU-590 (SY) CCU-790 (SY) HDC1000 (SY) HDC1100 (SY) HDC1400 (SY) HDC1450 (SY) HDC1500 (SY) HDC1550 (SY) HDC1580 (SY) HDC1600 (SY) HDC3300 (SY) HDCU1000 (SY) HDCU1080 (SY) HDCU1500 (SY) HDCU3300 (SY) MSU-900 (SY)

This manual is also suitable for:

Hdc1000 series

Table of Contents