Troubleshooting; Ka-Mr100G/Ka-Um100G Internal Cable Connection - JVC KA-MR100G Service Manual

Memory recorder, adapter
Hide thumbs Also See for KA-MR100G:
Table of Contents

Advertisement

5.1

KA-MR100G/KA-UM100G Internal Cable Connection

Note:
• After this modification, the IEEE1394 connector of KA-UM100G becomes no communication available.
• "Internal connected cable" is unnecessary in the GY-HM700 series.
5.1.1 Remove Left side cover
• Refer to see service manual (No.HC014) 1-1 and 1-2.
5.1.2 Open the CON cover
(1) Remove the 5 screws and take out sw cover.
(2) Remove the cable between SW pwb CN54 and DV OUT
pwb CN54.
*The removed cable is not used.
SECTION 5

TROUBLESHOOTING

Fig.1
Fig.2
Fig.3
Fig.4
5.1.3 Remove the battery mount plate
(The figure is Anton type for U-model. IDX type is mounted for
E-model.)
(1) Remove four screws.
(2) Remove four screws, and then the PS pwb cover.
<Internal Cable>
WJJ0994-001A-E
12P cable
Connect to CN105 of the KA-UM100G
Fig.5
Fig.6
Connect to CN54 of the SW PWB
Gray 6P cable
Blue 6P cable
Connect to CN54 of the DV OUT PWB
Fig.7
(No.HC027<Rev.001>)1-11