GE WattStation Pedestal Installation Manual page 14

Evse charger
Table of Contents

Advertisement

WattStation Pedestal Installation Manual
S S t t e e p p : : 1 1 6 6 Open the access door by unlocking
the key on back of the EVSE unit
(Below Top cover assembly)
S S t t e e p p : : 1 1 7 7 Route the Power wires and Ground
wires as shown in the figure 9
IMPORTANT: WattStation is rated
for 208-240V AC, 30Amps, 1 Phase, 60Hz
power only. The EVSE must be connected
to a centrally grounded system, The ground
conductor should be run with power conductors
and connected to the equipment grounding
lug inside the charger.
Connections to the EVSE are the responsibility
of the installer and purchaser, not GE, and
such connections must comply with
all applicable electrical codes and ordinances.
Torque all the nuts as per the torque
specification in Table 1,
Refer Table 2 for recommended tools.