ER R OR D ETEC TION INDOOR UNIT Lamps show error contents by flashing as follows. Troubleshooting with the indoor display TIMER FILTER OPERATION Error contents Error is displayed on the wired and Lamp Lamp Lamp wireless remote control. 2 times 3 times Indoor signal error FILTER Lamp (Red)
Page 9
REMOTE CONTROL (option) Troubleshooting at the remote control LCD This is possible only on the wired remote control. Error Error contents Self-diagnosis code If an error occurs, the following display will be shown. (“EE” will appear in the set room temperature display.) Indoor signal error Unit number Wired remote controller abnormal...
Page 10
OUTDOOR UNIT LED Make a TEST RUN in accordance with the installation instruction sheet for the indoor unit. When a malfunction occurs in the outdoor unit, the LED on the circuit board lights to indicate the error. Refer to the following table for the description of each error according to the LED.
Page 11
SPECIAL INSTALLATION SETTING PUMP DOWN (Refrigerant collecting operation) Perform the following procedures to collect the refrigerant when moving the indoor unit or outdoor unit 1. When the product is stopped: PUMP DOWN SW (SW2) Press the PUMP DOWN switch on the outdoor unit. (The LED on the outdoor unit circuit board starts flashing.) (1 sec.
PARTS INDOOR UNIT Ref. Description Part number Kit (Base Sub Assy) 9371360010 Panel Left Sub Assy 9360427014 Kit (Panel Right Assy) 9371361017 Cover (Top) 9359737001 Intake Grille 9359738008 Air Filter 9359739005 Filter Guide R 9359692003 Filter Guide L 9359693000 Front Panel 9359734000 Indicator PCB Assy 9705891043...
Page 13
INDOOR UNIT Drain pan, Flap Description Part number Ref. 2 Panel Left Sub Assy 9360427014 3 Kit (Panel Right Assy) 9371361017 21 Evaporator Assy 9372585078 22 Distributor Assy 9371325378 23 Coupling Pipe Assy 9373038405 24 Kit (Panel pipe L) Sub Assy 9371362014 25 Kit (Panel pipe R) Sub Assy 9371363011 26 Reinforcement Metal 9359697008...
Page 14
INDOOR UNIT Louver Base Sub Assy Ref. Description Part number 41 Louver Base Sub Assy 9360432025 42 Louver 9359719007 43 Rod (Motor) 9359723004 44 Louver Link 9359726005 45 Louver Base 9359718000 46 Louver Spring 9359720003 47 Louver Stopper 9359724001 48 Louver Rod 9359725008 49 Step Motor H 9900297015...
Page 15
INDOOR UNIT Fan motor Ref. Description Part number Motor Mount 9377999016 Fan Motor Assy 9602389018 Motor Band A assy 9374647019 Motor Band B 9374648023 Reinforcement Motor Band 9378000018 Rubber 9385102002 Casing 9359704003 Kit (Cover Casing) Sub Assy 9371367019 Sirocco Fan Assy 9359701002 Joint Assy 9378038011...
Page 16
Ref. Description Part number Control Box Assy 9377912015 INDOOR UNIT Control Box A 9359712008 Control unit Control Box B 9359713005 Controller PCB Assy 9707393453 Power Supply PCB Assy 9707398168 Terminal 3P 9703345012 Terminal 3P 9306489045 Reactor Assy 9707457018 Rubber Bushing 9357376004 Cord Clamp A 9359820017...
PARTS OUTDOOR UNIT Ref. Description Parts number Top Panel Sub Assy 9374417025 Front Panel 9374094028 Fan Guard 9374330010 Grip Side 9374173013 Service Panel Sub Assy 9374415069 Right Panel Sub Assy 9374416141 Valve Cover 9374174010 Emblem Rear 9351355005 2009.02.10...
Page 18
OUTDOOR UNIT Ref. Description Parts number Propeller Fan Assy 9366378020 Motor DC Brushless 9602843015 Condenser A Assy 9374433018 Condenser B Assy 9374434015 Separate Wall 9374629015 Cap Foot 9374345014 Base Assy 9374166046 Coil Choke 9703458019 2009.02.02...
ACCESSORIES INDOOR UNIT Name and Shape Q'ty Application Part number Drain hose Adhesive type 70 x 230 9360464002 insulation For fixing the drain hose VT wire 313806350303 L 280 mm Coupler heat For indoor side pipe joint insulator 9378173569 (large pipe) (large) Coupler heat For indoor side pipe joint...
Page 22
OPTIONAL PARTS Exterior Parts name Model No. Summary Wired Unit control is performed remote UTB-YUD by wired remote control control Round duct UTD-RF204 For Ceiling type Drain pump UTR-DPB241 For Ceiling type unit 2009.02.25...