Siemens SIMATIC NET SCALANCE W760 Operating Instructions Manual
Siemens SIMATIC NET SCALANCE W760 Operating Instructions Manual

Siemens SIMATIC NET SCALANCE W760 Operating Instructions Manual

Industrial
Hide thumbs Also See for SIMATIC NET SCALANCE W760:

Advertisement

Quick Links

SCALANCE W760/W720
SIMATIC NET
Industrial Wireless LAN
SCALANCE W760/W720
Operating Instructions
03/2015
C79000-G8976-C322-05
___________________
Information on the Internet
___________________
Introduction
___________________
Description
___________________
Mounting
___________________
Connection
___________________
Technical data
___________________
Dimension drawings
___________________
Approvals
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE W760

  • Page 1 ___________________ SCALANCE W760/W720 Information on the Internet ___________________ Introduction ___________________ SIMATIC NET Description ___________________ Mounting Industrial Wireless LAN SCALANCE W760/W720 ___________________ Connection ___________________ Technical data Operating Instructions ___________________ Dimension drawings ___________________ Approvals 03/2015 C79000-G8976-C322-05...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Contents Information on the Internet ........................5 Introduction ............................. 7 Information on the Operating Instructions ................7 Structure of the type designation ....................8 Security information ........................8 Description .............................. 9 Components of the product ...................... 9 LED display ..........................9 Reset button ..........................
  • Page 5: Information On The Internet

    Information on the Internet Bitte beachten Sie die Warnhinweise und zusätzlichen Informationen in der Kompaktbetriebsanleitung in Ihrer Sprache im Internet: http://support.automation.siemens.com/ww/view/at/10806097 http://support.automation.siemens.com/ww/view/ch/10806097 http://support.automation.siemens.com/ww/view/de/10806097 http://support.automation.siemens.com/ww/view/li/10806097 http://support.automation.siemens.com/ww/view/lu/10806097 Please observe the warnings and additional information in the compact operating instructions in your language in the Internet: http://support.automation.siemens.com/ww/view/au/10806097...
  • Page 6 Information on the Internet http://support.automation.siemens.com/ww/view/hk/10806097 http://support.automation.siemens.com/ww/view/sg/10806097 Kérjük, vegye figyelembe az interneten található, az Ön anyanyelvén íródott kompakt használati útmutatóban található figyelmeztetéseket és további információkat: http://support.automation.siemens.com/ww/view/hu/10806097 Skoðið vel viðvaranir og aðrar upplýsingar í notkunarleiðbeiningunum á ykkar tungumáli á internetinu: http://support.automation.siemens.com/ww/view/is/10806097 インターネットサイトにある各言語の注意事項および追加情報を参照してください: http://support.automation.siemens.com/ww/view/jp/10806097...
  • Page 7: Introduction

    Introduction Information on the Operating Instructions Validity of the Operating Instructions These operating instructions cover the following products: Article no. of the RoW version Article no. of the US version Access point SCALANCE W761-1 RJ-45 6GK5761-1FC00-0AA0 6GK5761-1FC00-0AB0 Ethernet client modules SCALANCE W722-1 RJ-45 6GK5722-1FC00-0AA0 6GK5722-1FC00-0AB0...
  • Page 8: Structure Of The Type Designation

    Security information Siemens provides automation and drive products with industrial security functions that support the secure operation of plants or machines. They are an important component in a holistic industrial security concept. With this in mind, our products undergo continuous development.
  • Page 9: Description

    ● 1 connector for the power supply ● SIMATIC NET Industrial Wireless LAN CD Please check that the consignment you have received is complete. If the consignment is incomplete, contact your supplier or your local Siemens office. LED display Information on operating status and data transfer...
  • Page 10 Description 3.2 LED display Color Meaning Green Power supply L1. Green There is a connection via the Ethernet interface (Link). Green and yel- Data transfer via the Ethernet interface. low flashing alternately SCALANCE W760 in access point mode: Green The WLAN interface is initialized and ready for operation. SCALANCE W760 in client mode or SCALANCE W720: There is a connection via the WLAN interface.
  • Page 11: Reset Button

    Description 3.3 Reset button Reset button ① The reset button (position ) is on the front of the housing: Functions of the reset button The reset button has the following functions: ● Restart of the device Note If you make changes to the configuration and restart immediately afterwards with the reset button, the changes may be lost.
  • Page 13: Mounting

    Mounting CAUTION Minimum distance to antennas Fit the device so that there is a minimum clearance of 20 cm between antennas and persons. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C.
  • Page 14: Installing On A Din Rail / Removing

    Mounting 4.1 Installing on a DIN rail / removing Installing on a DIN rail / removing Procedure for installation Follow the steps below to fit the SCALANCE W760/W720 to a DIN rail: 1. Place the device on the upper edge of the DIN rail as shown in the figure. 2.
  • Page 15: Connection

    Connection Lightning protection, power supply and grounding Lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system.
  • Page 16 Connection 5.1 Lightning protection, power supply and grounding Note We recommend that you use the maintenance-free lightning protector LP798-2N. Exception: When there is also DC power supplied via the antenna cable. In this case, only the lightning protector LP798-1N can be used. WARNING Danger due to lightning strikes Installing this lightning protector between an antenna and a SCALANCE W700 is not...
  • Page 17 Connection 5.1 Lightning protection, power supply and grounding Grounding WARNING Danger to life from overvoltage, fire hazard When using outdoor antennas, the shared or even grounded pin of the circuit must be connected to the shield of the coaxial cable and with all touchable conductive parts and circuits.
  • Page 18 Connection 5.1 Lightning protection, power supply and grounding General notes on use in hazardous areas according to UL-HazLoc WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only.
  • Page 19: Power Supply

    Connection 5.2 Power supply Power supply The power is supplied to the SCALANCE W760/W720 via the three-pin socket. Socket The three-pin socket has the following pin assignment: Assignment +24 VDC Ground Grounding SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05...
  • Page 20: Ethernet

    Connection 5.3 Ethernet Ethernet The SCALANCE W760/W720 has two Ethernet interfaces located on the underside of the ① device (position Suitable cables for power supply and Ethernet Cable specification The following table lists the requirements for a cable depending on the application. Application Specification Direct 24 VDC supply...
  • Page 21: Antenna Connector

    Connection 5.5 Antenna connector Antenna connector The SCALANCE W760/W720 has an antenna connector R1 A1 of the type R-SMA located ① on the front of the device (position Procedure Follow the steps below to connect a cable for an external antenna to a SCALANCE W760/720: ①...
  • Page 22: Suitable Antenna Cables And Antennas

    Connection 5.6 Suitable antenna cables and antennas Suitable antenna cables and antennas N-Connect/R-SMA connecting cable To connect an antenna with an N-Connector, the following cables are suitable: Length Order number 0.3 m 6XV1875-5CE30 6XV1875-5CH10 6XV1875-5CH20 6XV1875-5CH50 10 m 6XV1875-5CN10 Suitable antennas Note When you select an antenna, keep in mind the national approvals for your device.
  • Page 23 Connection 5.6 Suitable antenna cables and antennas ANT795-4MD Omnidirectional antenna, 3/5 dBi, 2.4 GHz 6GK5 795-4MD00-0AA3 and 5 GHz, IP65, N-Connect male for direct installation on the device, 90° con- nector. ANT795-4MA Omni antenna, directly on the device, 3/5 6GK5 795-4MA00-0AA3 2.4 GHz and 5 GHz, IP30, R-SMA con- nector male for direct mounting on the device, connector angle adjustable 0°...
  • Page 24 Connection 5.6 Suitable antenna cables and antennas Note ANT793-8DK The antenna ANT793-8DK may only be used with the antenna cable 6XV1875-5CN10 (10 m length). Other antenna cables are not permitted. Notice for USA/Canada Only one antenna per device can be used (connected to R1A1, R1A2 or R2A1, R2A2). SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05...
  • Page 25: Technical Data

    Technical data Technical specifications W761/W722/W721 RJ-45 The following technical specifications apply to the following devices: ● SCALANCE W761-1 RJ-45 ● SCALANCE W722-1 RJ-45 ● SCALANCE W721-1 RJ-45 Note You will find detailed information on the transmit power and receiver sensitivity in the document "Performance data 802.11 abgn SCALANCE W760/W720"...
  • Page 26 Technical data 6.1 Technical specifications W761/W722/W721 RJ-45 SCALANCE W761/W722/W721 Wireless interface Antenna connector Quantity Design R-SMA female Impedance 50 Ω nominal Frequency range 2412 ... 2480 MHz 4920 ... 5875 MHz Electrical data Power supply Supply voltage 24 VDC Safe Extra Low Voltage (SELV) Permitted range 19.2 to 28.8 VDC Design...
  • Page 27: Dimension Drawings

    Dimension drawings SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05...
  • Page 29: Approvals

    Approvals You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item.
  • Page 31: Index

    Index Antenna Reset button, 11 Connector, 21 Resetting the device, 11 Antennas Restart of the device, 11 Specification, 22 Article numbers, 7 Safety extra low voltage, 16 Scope of delivery, 9 Cables Supply voltage, 16 Specification, 20, 22 Connectors, 9 Technical specifications, 25 Type designation, 8 Dimension drawing, 27...
  • Page 32 Index SCALANCE W760/W720 Operating Instructions, 03/2015, C79000-G8976-C322-05...