Summary of Contents for D-Link RG-S8614

  • Page 1 RG-S8600 Series Switch Hardware Installation and Reference Guide V1.78...
  • Page 2 Copyright statement Ruijie Networks©2000-2014 Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited.
  • Page 3: Related Documents

    Preface Thank you for using our products. This manual will guide you through the installation of the switch. Scope It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts.
  • Page 4: Specifications

    The RG-S8600 switch provides dual management boards and dual power supplies for redundancy. Currently four models are available:  The RG-S8614: designed with 14 transverse slots, supporting dual management engine modules, providing 12 slots for service modules.  The RG-S8610: designed with 10 vertical slots, supporting dual management engine modules and providing eight slots for service modules.
  • Page 5: Product Appearance

    10% ~ 90% RH (non-condensing) Humidity Earthquake Able to resist the earthquake intensity 9 Resistance ≤114 kg Weight Dimensions 436.8 mm x 508 mm x 932.2 mm, 21 RU (W x D x H) Product Appearance Figure 1-1 Appearance of the RG-S8614 Switch...
  • Page 6 Module Slot The RG-S8614 switch provides 14 module slots, of which two in the middle are only for the management modules. The 12 slots on the top and the bottom can accommodate a mix of various modules. Modules are inserted horizontally, with the same height of 412 mm, and depth of 350 mm.
  • Page 7 Ventilation and Heat Dissipation System The operating temperature of the RG-S8614 switch is 0 to 40° C. The thermal design must ensure that the surface temperature of the components does not exceed 50% to 80% of the allowed maximum temperature and satisfy the requirement on the device’s reliability in the temperature range while ensuring the device’s reliability, safety and...
  • Page 8 Figure 1-2 Ventilation and Heat Dissipation System of the RG-S8614 Switch  This structure is designed with air inlet on two sides, and air outlet at the back. The air flow direction is shown above. Ten 120 x 120 x 38 fans are used to blow air outside for convection and ultimately heat dissipation. The chassis should be mounted in a place with sufficient space for air circulation.
  • Page 9 M8610-CM M8610-CM II M8610-CM III M8610-CM II LITE M8600-24SFP/12GT M8600-24GT/12SFP M8600P-24GT/12SFP M8600-02XFP M8600-48GT/4SFP M8600P-48GT/4SFP M8600-04XFP M8600-24SFP M8600-MPLS M8600-NMM M8600-02XFP24SFP/12GT-E Module Type M8600-08XFP M8600-VSU-02XFP M8600-FW RG-WALL 1600-B-E RG-WALL 1600-B-U RG-WALL 1600 FW Module M8600-WS M8600-02XFP24SFP/12GT-EC M8600-24SFP/12GT-EC M8600-48GT/4SFP-EC M8600P-48GT/4SFP-EC M8600-24GT/12SFP-EC M8600-04XFP-EC M8600-04QXS-DA M8600-16XS-DA Hot Swapping Supported...
  • Page 10 Product Appearance Figure 1-3 Appearance of the RG-S8610 Switch        Note: Air outlet layer: the air outlet layer of the whole system, discharge air to the outside on three sides  Fan tray: slot of the fan tray, the active heat dissipation unit of the system ...
  • Page 11 Chassis The RG-S8614 has a standard 19-inch chassis, which is 956mm high, 436.8mm wide and 448mm deep. It consists of the system modular layer, the fan layer, air inlet/outlet layers, the cable management bracket, the air filter and the power system layer.
  • Page 12 Figure 1-4 Ventilation and Heat Dissipation System of the RG-S8610 Switch  This structure is designed with air inlet at the front and back and on both sides, and air outlet at the back and on both sides. The air flow direction is shown above. Six 120 x 120 x 38 fans are used to blow air outside for convection and ultimately heat dissipation.
  • Page 13 M8606-CM M8606-CM II M8606-CM III M8606-CM II LITE M8600-24SFP/12GT M8600-24GT/12SFP M8600P-24GT/12SFP M8600-02XFP M8600-48GT/4SFP M8600P-48GT/4SFP M8600-04XFP M8600-24SFP M8600-MPLS M8600-NMM Module Type M8600-02XFP24SFP/12GT-E M8600-08XFP M8600-VSU-02XFP M8600-FW RG-WALL 1600-B-E RG-WALL 1600-B-U RG-WALL 1600 FW Module M8600-WS M8600-02XFP24SFP/12GT-EC M8600-24SFP/12GT-EC M8600-48GT/4SFP-EC M8600P-48GT/4SFP-EC M8600-24GT/12SFP-EC M8600-04XFP-EC Hot Swapping Supported Management Redundancy Supported...
  • Page 14 The RG-S8606’s hardware system is composed of the chassis, the power system, modules and the fan tray. Chassis The RG-S8614 has a standard 19-inch chassis, which is 674.4mm high, 436.8mm wide and 508mm deep. It the system modular layer, the fan layer, the air filter and the power system layer.
  • Page 15 The slots for the two management modules are in the middle and identified as M1 and M2 from bottom to top; the other four line cards are numbered 1-4 from bottom to top. Backplane The RG-S8606’s backplane interconnects high-speed data links from switch management board to module circuit board and various management and control signals between modules.
  • Page 16 M8606-CM II M8606-CM III M8606-CM II LITE M8600-24SFP/12GT M8600-24GT/12SFP M8600P-24GT/12SFP M8600-02XFP M8600-48GT/4SFP M8600P-48GT/4SFP M8600-04XFP M8600-24SFP M8600-MPLS M8600-NMM Module Type M8600-02XFP24SFP/12GT-E M8600-08XFP M8600-VSU-02XFP M8600-FW RG-WALL 1600-B-E RG-WALL 1600-B-U RG-WALL 1600 FW Module M8600-WS M8600-02XFP24SFP/12GT-EC M8600-24SFP/12GT-EC M8600-48GT/4SFP-EC M8600P-48GT/4SFP-EC M8600-24GT/12SFP-EC M8600-04XFP-EC Hot Swapping Supported Management Redundancy Supported...
  • Page 17     Note: Modular layer: offers up to six module slots  Power layer: supports up to two AC or DC power supplies  Air outlet: Locates in the back of the chassis, the air-outlet unit of the system.
  • Page 18 the thermal design of the RG-S8606 B, fans are used to draw air for forced convection cooling in order to ensure that the device works properly in the specified environment.
  • Page 19 L2/L3 protocol processing, route management, user access control and management, and network and operation maintenance. As the switching and central control module of the RG-S8614/S8610/S8606, it largely enhances the processing capability of the processor on the basis of the M8614/M8610/M8606-CM II M8610/M8606-CM.The module manages the entire system, including L2/L3 protocol...
  • Page 20 It provides forty-four 10/100/1000BASE-T RJ45 ports and four fiber/copper combo M8600-48GT/4SFP ports. The SFP ports support the rate of 1000M, and the RJ-45 ports support auto-negotiation at 10/100/1000M. The SFP optical modules support hot swapping. It provides forty-four 10/100/1000BASE-T RJ45 ports and four fiber/copper combo ports.
  • Page 21: Module Appearance

    It is the AC power module of the system. Instead of providing an input interface, it is RG-PA800IF directly powered by the 220V AC through the interface on the back of the S8606 B chassis. M8610/M8606-CM M8610-CM is the primary management module of the RG-S8610; M8606-CM is the primary management module of RG-S8606.M8610/M8606-CM performs such functions as system switching, system status control, route management, user access control and management, and network maintenance.
  • Page 22 Specifications Model M8610-CM M8606-CM Standard Compliance IEEE 802.3-2005 Ethernet Standard Management Mode CLI, Telnet, Web-based Port Type One console port for management, one 10/100M MGMT port, one USB port Status, Primary, Alarm and MGMT port LEDs Hot Swapping Supported Management Supported Redundancy Power Consumption...
  • Page 23 Dispose of used batteries in a proper way. M8614/M8610/M8606-CM II The M8614-CM II is the primary management module of the RG-S8614; the M8610-CM II is the primary management module of the RG-S8610; and the M8606-CM II is the primary management module of the RG-S8606. The M8614/M8610/M8606-CM II performs such functions as system switching, system status control, route management, user access control and management, and network maintenance.
  • Page 24 Figure 1-15 Appearance of M8610-CM II External Interface The M8614/M8610/M8606-CM II module provides three external interfaces:  USB (Universal Serial Bus) interface: By connecting the USB interface, USB storage devices can keep logs, host version, alarms and other diagnosis information, facilitating online upgrade of switch software and log saving. ...
  • Page 25 Weight Net weight: 3.5 kg Net weight: 2.8 kg Net weight: 2.8 kg Dimensions 436 mm x 346 mm x 30 436 mm x 346 mm x 30 mm 433 mm x 346 mm x 30 mm (L x W x H) ...
  • Page 26 Sign Description Detailed information OFF: The module is not powered on. Red: The module is faulty. Blinking green: The module is initializing. If it keeps blinking, the module Status System LED may be faulty. Solid green: The module has finished initialization and can perform switching well.
  • Page 27 OFF: The module is not powered on. Red: The module is faulty. Status System LED Blinking green: The module is initializing. If it keeps blinking, the module may be faulty. Solid green: The module has finished initialization and can perform switching well. Optical module OFF: The optical module is not available.
  • Page 28 RJ45 port: OFF: The port link is not up. Green: The port link is up at 1000 Mbps. Orange: The port link is up at 10/100 Mbps. Link/ACT Port status LED Blinking: The port is sending and receiving data. SFP port: OFF: The port link is not up.
  • Page 29 OFF: The port link is not up. Link/ACT Port status LED Green: The port link is up. Blinking green: The port is sending and receiving data.
  • Page 30 Specifications Model M8600-02XFP Standard IEEE 802.3-2005 Ethernet Standard Compliance Port Type Two 10G XFP ports. 10GBASE-SR(850nm) Multi-mode optical fiber Transmission 10GBASE-LR(1310nm) Single-mode optical fiber Medium 10GBASE-ER(1550nm) Single-mode optical fiber Status, Link/ACT Hot Swapping Supported Power <75W Consumption EMC Standards GB9254-2008 Safety Standards GB4943-2011 Operating...
  • Page 31 Sign Description Detailed information OFF: The module is not powered on. Red: The module is faulty. Status System LED Blinking green: The module is initializing. Solid green: The module has finished initialization and can perform switching well. Green: The module is working in the switching mode. Mode Operating mode LED Yellow: The module is working in the PoE mode.
  • Page 32 3. Configure the pull-out operation through software commands. (For relevant software configuration commands, refer to the corresponding software description.)
  • Page 33 M8600-48GT/4SFP Module Appearance Figure 1-22 Appearance of the M8600-48GT/4SFP External Interface The M8600-48GT/4SFP provides forty-four 10/100/1000BASE-T RJ45 ports and four fiber/copper combo ports. The SFP ports support the rate of 1000Mbps, RJ45 ports support auto-negotiation at 10/100/1000 Mbps and the SFP optical modules support hot swapping.
  • Page 34 M8600-04XFP Module Appearance Figure 1-23 Appearance of the M8600-04XFP External Interface The M8600-04XFP provides four 10G XFP ports. The XFP optical modules support hot swapping. Sign Description Detailed information OFF: The module is not powered on. Red: The module is faulty. Blinking green: The module is initializing.
  • Page 35 The Mode button has the following functions:  Press the “Mode” button, and the port LED indicates switchover between switching mode and PoE mode upon releasing the button.  In the PoE mode, if the PSE is supplying power to PDs, pressing the “Mode” button and holding it for about three seconds causes the PSE to stop supplying power to PDs upon releasing the button.
  • Page 36  The M8600-48GT/4SFP module provides four 10/100/1000BASE-T SFP combo ports. Each SFP port corresponds to one combo 10/100/1000BASE-T port, and only one port can be used at a time, while the other is unavailable. The automatic MDI/MDI-X identification of the 10/100/1000M copper ports takes effect only when auto-negotiation is enabled.
  • Page 37 Dimensions 436 mm x 346 mm x 45 mm (L x W x H) M8600-MPLS The M8600-MPLS is an agent card that supports MPLS. The MPLS function of S8600 switches can be expanded. Module Appearance Figure 1-26 Appearance of the M8600-MPLS External Interface The M8600-MPLS module provides no external ports.
  • Page 38 OFF: The module is not powered on. Red: The module is faulty. Blinking green: The module is initializing. If it keeps blinking, the Status System LED module may be faulty. Solid green: The module has finished initialization and can perform switching well. Specifications Model M8600-NMM...
  • Page 39 Weight Net weight: 3.5 kg Dimensions 436 mm x 346 mm x 45 mm (L x W x H) M8600-02XFP24SFP/12GT-E Module Appearance Figure 1-29 Appearance of the M8600-02XFP24SFP/12GT-E External Interface The M8600-02XFP24SFP/12GT-E provides two 10G XFP ports, twelve SFP ports and twelve fiber/copper combo ports. The SFP ports support the rate of 1000Mbps, the RJ45 ports support auto-negotiation at 10/100/1000 Mbps and the XFP and SFP optical modules support hot swapping.
  • Page 40 M8600-VSU-02XFP The M8600-VSU-02XFP module supports the VSU function. Module Appearance Figure 1-30 Appearance of the M8600-VSU-02XFP External Interface The M8600-VSU-02XFP provides two 10G XFP ports. The XFP optical modules support hot swapping. Sign Description Detailed information OFF: The module is not powered on. Red: The module is faulty.
  • Page 41 M8600-FW The M8600-FW is a service card that supports the firewall function. The firewall function of S8600 switches can be expanded. Module Appearance Figure 1-31 Appearance of the M8600-FW External Interface The M8600-FW module provides two external interfaces:  Console port: As the serial communications port, it uses RS-232 interface level and standard RJ-45 connector. This port is used to connect the serial port of terminal computers running on the background for such tasks as firewall debugging, configuration, maintenance, management, and host software loading.
  • Page 42 RG-WALL1600-B-E The RG-WALL 1600-B-E is a service card that supports the firewall function and can expand the firewall function of S8600 switches. Module Appearance Figure 1-32 Appearance of the RG-WALL 1600-B-E External Interface The RG-WALL 1600-B-E module provides two external interfaces: ...
  • Page 43 Module Appearance Figure 1-33 Appearance of the RG-WALL 1600-B-U External Interface The RG-WALL 1600-B-U module provides two external interfaces:  Console port: As the serial communications port, it uses RS-232 interface level and standard RJ-45 connector. This port is used to connect the serial port of terminal computers running on the background for tasks such as firewall debugging, configuration, maintenance, management, and host software loading.
  • Page 44 External Interface The RG-WALL 1600 FW module provides two external interfaces:  Console port: As the serial communications port, it uses RS-232 interface level and standard RJ-45 connector. This port is used to connect the serial port of terminal computers running on the background for such tasks as firewall debugging, configuration, maintenance, management, and host software loading.
  • Page 45 External Interface The M8600-WS module provides two external interfaces:  Console port: As the serial communications port, it uses RS-232 interface level and standard RJ-45 connector. This port is used to connect the serial port of terminal computers running on the background for such tasks as the debugging, configuration, maintenance, management, and host software loading of the wireless control card.
  • Page 46 OFF: The module is not powered on. Red: The module is faulty. Blinking green: The module is initializing. If it keeps blinking, the Status System LED module may be faulty. Solid green: The module has finished initialization and can perform switching well.
  • Page 47 External Interface The M8600-24SFP/12GT-EC provides 12 SFP ports and 12 fiber/copper combo ports. The SFP ports support the rate of 100/1000 Mbps, the RJ-45 ports support auto-negotiation at 10/100/1000 Mbps, and the SFP optical modules support hot swapping. Sign Description Detailed information OFF: The module is not powered on.
  • Page 48 Figure 1-38 Appearance of the M8600-48GT/4SFP-EC External Interface The M8600-48GT/4SFP-EC provides forty-four 10/100/1000BASE-T RJ45 ports and four fiber/copper combo ports. The SFP ports support the rate of 100/1000 Mbps, the RJ45 ports support auto-negotiation at 10/100/1000 Mbps and the SFP optical modules support hot swapping.
  • Page 49 M8600P-48GT/4SFP-EC Module Appearance Figure 1-39 Appearance of the M8600P-48GT/4SFP-EC External Interface The M8600P-48GT/4SFP-EC provides forty-four 10/100/1000BASE-T RJ45 ports and four fiber/copper combo ports. The SFP ports support the rate of 100/1000 Mbps, the RJ45 ports support auto-negotiation at 10/100/1000 Mbps and PoE function, and the SFP optical modules support hot swapping.
  • Page 50 1000BASE-SX(850nm) Multi-mode optical fiber 1000BASE-LX(1310nm) Single-mode optical fiber 1000BASE-LH40(1310nm) Single-mode optical fiber Transmission Medium 1000BASE-ZX(1550nm) Single-mode optical fiber 100BASE-FX(1310nm) Multi-mode or single-mode optical fiber 100BASE-FX(1550nm) Single-mode optical fiber 10/100/1000BASE-T Cat-5 UTP Status, Link/ACT Hot Swapping Supported Power Consumption <121W+15.4xN (N indicates the number of PoE ports being used, N<=48) EMC Standards GB9254-2008 Safety Standards...
  • Page 51 RJ45 port: OFF: The port link is not up. Green: The port link is up at 1000 Mbps. Yellow: The port link is up at 10/100 Mbps. Blinking: The port is sending and receiving data. Link/ACT Port status LED SFP port: OFF: The port link is not up.
  • Page 52 OFF: The module is not powered on. Red: The module is faulty. Blinking green: The module is initializing. If it keeps blinking, the Status System LED module may be faulty. Solid green: The module has finished initialization and can perform switching well.
  • Page 53 M8600-04QXS-DA Module Appearance Figure 1-42 Appearance of the M8600-04QXS-DA External Interface The M8600-04QXS-DA provides four QSFP+ ports. The QSFP+ ports support 40G QSFP+ modules working in 40G mode. Hot swapping of the M8600-04QXS-DA and QSFP+ modules is supported. Identification Status Meaning on the panel The module is NOT receiving power.
  • Page 54 M8614/M8610/M8606-FAN/M8606-FAN B The M8614-FAN is the fan module of the RG-S8614; the M8610-FAN is the fan module of the RG-S8610; the M8606-FAN is the fan module of the RG-S8606; and M8606-FAN B is the fan module of the RG-S8606 B. M8614/M8610/M8606-FAN...
  • Page 55 The depth of the M8614/M8606 fan module excludes the depth of the handle and captive screw. RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000/PA800IF The AC power module RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000 provides 110/220V AC power input module for the RG-S8614/S8610/S8606. The AC power module RG-PA800IF provides 110/220V AC power input interface for the RG-S8606B. RG-PA1200/PA1200E/PA1200I/PA2000I/PA2000 Module...
  • Page 56 2000W 800W Power Cable  The RG-S8614/S8610/S8606/S8606 B system supports 1+1 redundancy for the power supply. For higher stability and reliability of the entire system, you are recommended to configure 1+1 power module redundancy for the RG-S8614/S8610/S8606/S8606 B.  In dual power mode, shut down the power switch if PA1200/PA1200E/PD1200/PD2000 and PA2000 V1.00/V1.01/V1.02 coexist.
  • Page 57: Chapter 2 Preparation Before Installation

    Do not wear loose clothes or any other things that may be caught by the chassis during installation and maintenance.  Turn off all power supplies and unplug all power cords before you move the chassis. RG-S8614/S8610/S8606/S8606 B is large and heavy. When you handle them, please pay attention to the following requirement: ...
  • Page 58 Figure 2-3 Moving the RG-S8606 Switch Figure 2-4 Moving the RG-S8606 B Switch...
  • Page 59: Electrical Safety Precautions

    Direct contact or indirect contact through a wet object with high-voltage and mains supply can bring a fatal danger. Static Discharge Damage Prevention Although much has been done in RG-S8614/S8610/S8606/S8606 B to prevent static electricity, great damage may be caused to the circuitry and equipment when the static electricity exceeds a certain limit. Electrostatic induction may come from the following sources: External electric field produced by the high-voltage supply cable and lightning, and internal systems such as the indoor floor and the entire structure.
  • Page 60: Wearing An Anti-Static Wrist Trap

     Properly ground the equipment.  Take dust prevention measures in the room.  Maintain an appropriate humidity.  Always wear an anti-static wrist strap when you touch any circuit board.  Try to hold a circuit board by its edges. Do not touch any components or the PCB. ...
  • Page 61: Laser Safety

    Do not get close to or stare into any optical port under any circumstances, as this may cause permanent damage to your eyes. Installation Site Requirements RG-S8614/S8610/S8606/S8606 B must be used in the room. To ensure normal operation and a prolonged use life of the equipment, the installation site must meet the following requirements. Rack Mounting Requirements To mount the RG-S8614/S8610/S8606/S8606 B in a frame, verify that the frame meets the following conditions: ...
  • Page 62 Figure 2-6 Ventilation of RG-S8614...
  • Page 63 Figure 2-7 Ventilation of RG-S8610 Figure 2-8 Ventilation of RG-S8606...
  • Page 64: Temperature And Humidity Requirements

    Temperature and Humidity Requirements To ensure the normal operation and a prolonged use life of the RG-S8614/S8610/S8606/S8606 B, you must maintain an appropriate temperature and humidity in the equipment room. Too high or low temperature and humidity for a long period of time may damage the equipment.
  • Page 65: Cleanness Requirements

    ≤3×10  The air filter of the RG-S8614/S8610/S8606 B must be cleaned regularly to ensure good ventilation and dust prevention. Apart from dust, the salt, acid and sulfide in the air in the equipment room must also meet strict requirements; as such poisonous substances may accelerate the corrosion of the metal and the aging of some parts.
  • Page 66 System Grounding Requirements A good grounding system is the basis for the stable and reliable operation of the RG-S8614/S8610/S8606/S8606 B. It is the key to prevent lightning strike and resist interference. Please carefully check the grounding conditions on the installation site according to the grounding requirements, and perform grounding properly as needed.
  • Page 67: Precaution For Fiber Connection

    Special-purpose Tools Anti-static tool Meter Multimeter  RG-S8614/S8610/S8606/S8606 B series is not shipped with a tool kit. You need to prepare a tool kit by yourself. Unpacking Requirements Goods Checklist All panels have been properly installed and commissioned. Chassis Packing...
  • Page 68: Installation Procedure

    Chapter 3 Product Installation  Before you install the RG-S8614/S8610/S8606/S8606 B, make sure you have carefully read Chapter 2 and this part.  Be sure that the requirements set forth in part 2 have been met. Installation Procedure...
  • Page 69: Installation Verification

    Installation Verification The RG-S8614/S8610/S8606/S8606 B is complicated equipment, so you must carefully plan the installation location, networking mode, power supply, and wiring before installation. Verify the following before installation:  The installation location meets the heat dissipation requirements..  The installation environment meets the temperature and humidity requirements ...
  • Page 70: Cabinet Installation

    M8610-FAN <60W M8606-FAN <60W M8606-FAN B <150W Consumption of power supplies Power Modules Maximum Output Power (W) RG-PA1200 1200 W RG-PA2000 90–176 VAC, power: 1200 W; 176–264 VAC, power: 2000 W RG-PA1200E 1200 W RG-PA1200I 90–176 VAC, power:530 W; 176–264 VAC, power:1400 W RG-PA2000I 90–176 VAC, power:1080 W;...
  • Page 71: Mounting Into The Cabinet

    Precautions Before mounting RG-S8614/S8610/S8606/S8606 B into the cabinet, first verify that the front and back brackets of the cabinet are at the right locations. If the bracket is too far forward, the front panel of the equipment may be too close to the front door, and the front door cannot be closed when network cables and pigtail fibers are connected.
  • Page 72: Installing Fan Tray

    Simple Installation Steps Horizontally lift the RG-S8614/S8610/S8606/S8606 B by two people on both sides, and slowly move it to the front of the cabinet. Horizontally lift the RG-S8614/S8610/S8606/S8606 B to a position slightly higher than the tray or the slide rail of the cabinet, put the equipment onto the tray or the slide rail, and push it into the cabinet.
  • Page 73 Figure 3-3 Installing the Fan Tray of the RG-S8610 Switch Figure 3-4 Installing the Fan Tray of the RG-S8606 Switch...
  • Page 74: Installing Power Supply

    Figure 3-5 Installing the Fan Tray of the RG-S8606 B Switch Installing Power Supply RG-S8614/S8610/S8606 system provides RG-PA1200, RG-PA1200E, RG-PA2000, RG-PA1200I and RG-PA2000I, as well as RG-PD1200 and RG-PD2000, and the RG-S8606 B system provides the RG-PA800IF only. These power modules can be installed in the same way according to the following steps: Before taking the following steps, wear an anti-static wrist trap close to your kin and have it properly grounded.
  • Page 75 Remove any blank panel of the power module by loosening the two cross screws with a Phillips screwdriver. Figure 3-6 Installing the Power Supply of the RG-S8614 Switch Figure 3-7 Installing the Power Supply of the RG-S8610 Switch...
  • Page 76 Figure 3-8 Installing the Power Supply of the RG-S8606 Switch...
  • Page 77 Insert the power module into the cabinet along the guide rail (The power supply slot of RG-S8606 B switch is not provided with a special guide rail, it uses the slot to control the direction.). Figure 3-10 Installing the Power Supply of the RG-S8614 Switch...
  • Page 78 Figure 3-11 Installing the Power Supply of the RG-S8610 Switch Power Guide Rail Figure 3-12 Installing the Power Supply of the RG-S8606 Switch...
  • Page 79 Figure 3-13 Installing the Power Supply of the RG-S8606 B Switch Tighten the screws on both sides of the power supply by using a Phillips screwdriver (Only one side of power supply of RG-S8606 B has the screw.). Figure 3-14 Installing the Power Supply of the RG-S8614 Switch...
  • Page 80 Figure 3-15 Installing the Power Supply of the RG-S8610 Switch Figure 3-16 Installing the Power Supply of the RG-S8606 Switch...
  • Page 81 Figure 3-17 Installing the Power Supply of the RG-S8606 B Switch The RG-PA1200I and RG-PA2000I are provided with the power defense shedding plugs, which should be installed. Figure 3-18 Appearance of Power Plug Retention Clip ① Power plug retention Note: clip...
  • Page 82: Installing Handles

    Installing Handles RG-S8614/S8610/S8606 comes with handles for easy moving. The handle can be installed according to the following steps: Align the handle with the sunk hole on the fastening bar; Tighten the supplied cross M4 sunk screws. Figure 3-19 Installing the Handle of the RG-S8614 Switch...
  • Page 83 Figure 3-21 Installing the Handle of the RG-S8606 Switch Installing Cable Management Bracket To install cable management bracket for RG-S8610/S8606 B, perform the following steps: For S8610: Remove the blank panel of the cable management bracket by loosening the captive screws with a flat screwdriver and the cross screws with a Phillips screwdriver.
  • Page 84 For S8610: Install the panel of the cable management bracket by tightening the two captive screws with a flat screwdriver and the four cross screws with a Phillips screwdriver. For S8606 B: Make the cabling opening of the cable management bracket face upward, install the cable management bracket one by one according to the slot corresponding to line card and cabling requirements, and then tighten the screws at the back of cable management brackets with a Phillips screwdriver.
  • Page 85: Installing Air Filter

    Figure 3-25 Installing the Cable Management Bracket Installing Air Filter Simply push the air filter into the cabinet of the RG-S8614/S8610/S8606 B along the guide rail,. Figure 3-26 Installing the Air filter of the RG-S8614 Switch...
  • Page 86 Figure 3-27 Installing the Air Filter for RG-S8610 Figure 3-28 Installing the Air Filter of the RG-S8610/S8606 B Switch...
  • Page 87: Simple Grounding Steps

    Grounding A PGND is installed on the back of RG-S8614/S8610/S8606/S8606 B. You must first connect the PGND to the grounding terminal of the cabinet and then connect the grounding terminal to the grounding bar of the equipment room (or the analog bar if there are digital grounding bar and analog grounding bar).
  • Page 88 The RG-PD1200 and RG-PD2000 are installed in a similar way. The following procedure describes how to install the RG-PD1200, as shown in Figure 3-29: Take out the RG-PD1200 and DC power cable from the packing case. Install the RG-PD1200 into the power slot in the chassis.
  • Page 89: Simple Connection Steps

    Figure 3-31 Installing RG-PD1200 V2.10 or Later Wiring terminals Insulationg cover Precautions  Before connecting the power supply, you must verify that the external power supply matches the power module installed in this equipment.  Before connecting the power cable, be sure that the switch of the power module is in the OFF position. ...
  • Page 90 Connect the DB-9 female to the serial port of the PC or terminal on which the switch is configured, and the RJ-45 end to the console port of management board.  The RG-S8614/S8610/S8606/S8606 B system must have at least one management module to work normally.
  • Page 91: Steps For Removing Boards

     If you want to remove the board when the device is electrified, you need to insert the new board or install the blank module panel within 10 minutes. Figure 3-33 Board Components of the RG-S8614...
  • Page 92 Figure 3-34 Board Components of the RG-S8610 Figure 3-35 Board Components of RG-S8606...
  • Page 93: Installing Boards

    Figure 3-36 Board Components of RG-S8606 B Installing Boards Precautions Always wear an anti-static wrist strap when unplugging the module and the metallic part of the anti-static wrist strap should be in full contact with the skin. Besides, for the sake of security, do not touch any component of the module. Simple Steps of Board Installation Remove the appropriate component card or blank panel according to section 3.14.
  • Page 94: Connecting The External Interface Cables

    Connecting the External Interface Cables Precautions  Correctly distinguish single-mode and multimode fibers and ports.  Avoid bends of small radius at the connector. Simple Connection Steps Connect the RJ-45 end of the Ethernet cable to the Ethernet interface of the device board and the other end to the NMS or a control terminal;...
  • Page 95: Specification

    Upgrade Instruction for MEM-CM-512 Memory Bank Precautions You must wear anti-static wrist straps when changing the memory bank. The metallic part of the anti-static wrist strap should be in full contact with the skin. Besides, for the sake of security, do not touch any component on the memory bank. Specification Attribute Description...
  • Page 96: Installing Swappable Interface Modules (Optional)

    Figure 3-38: Replacing the Memory Bank  As a memory slot has locks, you cannot lock a memory bank that is not properly installed. When seated in place, the memory bank can be tightly secured. Installing Swappable Interface Modules (Optional) During the following procedures, wear an anti-static wrist trap close to your kin and have it properly grounded.
  • Page 97: Replacing Swappable Interface Modules (Optional)

    Figure 3-39 Installing XFP/SFP+/SFP Modules Installing SFP+ Cables SFP+ cables can be used for connection over a short distance between SFP+ ports. Take the following steps to install SFP+ cables: Take out SFP+ cables from the packing bag. Insert the connector of an SFP+ cable lengthwise into the switch’s SFP+ port. ...
  • Page 98 Replacing SFP+ Cables Take the following steps to replace an SFP+ cable: Gently push in the connector of an SFP+ cable. Pull the handle at the back of the cable to pull the SFP+ cable connector out of the SFP+ port on the switch. ...
  • Page 99: Chapter 4 Monitoring And Maintenance

    Replacing LCD The LCD installed on the top of the RG-S8614/S8610/S8606 chassis is hot swappable. You can replace the LCD without breaking off the operation of the device in cases of an LCD failure. To replace an LCD, do as follows: Handle the grooves on both sides of the LCD with your hands and then disconnect the LCD from the chassis.
  • Page 100 Install the LCD: Align the DB-25 connector of the cable with the corresponding connector on the circuit board and then insert it. Tighten the screws on the connector with a magnetic screwdriver. At this point, the LCD works if the device works properly.
  • Page 101: General Installation Troubleshooting Flow

    Chapter 5 Troubleshooting General Installation Troubleshooting Flow Abnormal working after installation Check the cabinet installation Check the mounting of the RG-S8614/S8610/ S8606/S8606 B switch in the cabinet Check the power connection Check the installation of the power module Check the line cards and other...
  • Page 102 Fault 2: The AC power module does not work. [Symptom] The Status LED of each line card is OFF, the Power LED of the fan tray is OFF (only on the RG-S8610 and S8606 B), and the fan does not work. The LED on the panel of the power module is OFF.
  • Page 103 Therefore, you need to check whether the power switch is turned on and check whether the AC power cable is connected when the Alarm LED is red. Fault 7: The fan tray does not work or an exception occurs to the LED. [Symptom] After the system starts, the fans in the fan tray do not work or the Power LED is OFF, and the Alarm LED is red.
  • Page 104: Appendix A Connectors And Connection Media

    Appendix A Connectors and Connection Media 1000BASE-T/100BASE-TX/10BASE-T Port 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses up to 100 m of 100-ohm Category-5 or Supper Category-5 UTP or STP cables.
  • Page 105: Appendix B Mini-Gbic, 10-Gigabit Sfp+ And 40-Gigabit Qsfp+ Modules Specifications

    Appendix B Mini-GBIC, 10-Gigabit SFP+ and 40-Gigabit QSFP+ Modules Specifications Ruijie provides various Gigabit SFP (Mini-GBIC modules), 10-Gigabit SFP+ and 40-Gigabit QSFP+ transceivers for interfaces of modules on the switch. You can select the most suitable SFP, SFP+ or QSFP+ transceivers as needed. This appendix describes the models and specifications of some of the Gigabit SFP, 10-Gigabit and 40-Gigabit QSFP+ transceivers for your reference.
  • Page 106  Cabling specification for 1000Base-T port 1000Base-T Copper Cable Type Cabling Distance MiniGBIC-GT Cat-5 or better unshielded twisted pair or shielded twisted pair 100m Models and Technical Specifications of the 10G XFP Module  Models and Technical Specifications of the 10G XFP Module Maximu Sending Receiving...
  • Page 107 connecto 40-Gigabit QSFP+ Models and Specifications  Models and Specifications of 40-Gigabit QSFP+ Modules Modular Support Sending Receiving Core Wavelength Bandwidth Cable Optical Optical Model Fiber Type Size (nm) (MHz/km) distance (Yes/No) Density Density (nm) (dBm) (dBm) 2000 40G-Q 100m(OM3) -7.6 SFP-S -9.5 to 2.4...
  • Page 108: Appendix C Switch Lightning Protection

    Appendix C Switch Lightning Protection Installing AC Surge Arrestor (lightning protection cable row) The external lightning protection cable row shall be used on the AC power port to prevent the switch from being struck by lightning when the AC power cable is introduced from outdoors and directly connected to the power port of the switch. The lightning protection cable row is fixed on the cabinet, operating table or the wall in the machine room using the line buttons and screws.
  • Page 109 paste the Ethernet port lightning arrestor to the switch shell. The Ethernet port lightning arrestor shall be pasted as closely as possible to the grounding terminal of the switch. Based on the distance of the switch grounding terminal, cut short the grounding line for the Ethernet port arrestor and firmly tighten the grounding line to the grounding terminal of the switch.
  • Page 110: Appendix D Cabling Recommendations In Installation

    Appendix D Cabling Recommendations in Installation When RG-S8600 series switches are installed in standard 19-inch cabinets, the cables are tied in the binding rack on the cabinet by the cable management bracket, and top cabling or bottom cabling is adopted according to the actual situation in the equipment room.
  • Page 111  After bundling up cables with buckles, you should cut off the remaining part. The cut should be smooth and trim, without sharp corners, as shown in Figure D-2. Figure D-2 Bundling up cables (2)  When cables need to bend, you should first bundle them up. However, the buckle cannot be bundled within the bend area.
  • Page 112 Figure D-4 Cable fastening  The hard power cable should be fastened by the terminal connection area to prevent stress.  Do not use self-tapping screws to fasten terminals.  Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with cables in cable bunches clean and straight.
  • Page 113: Appendix E Power Cable Specifications

    Appendix E Power Cable Specifications AC Power Cables AC power cables connect a switch’s AC power module to an external AC power system. The current-carrying capacity varies with AC power cables. Be sure to choose suitable AC power cables based on their current-carrying capacity. The following table lists specifications of three power cable modules: Country, Region and Power Supply Model Name and...
  • Page 114 Country, Region and Power Supply Name and Specification Material Code Model According to Safety Certification Safety Certification Requirements DC power cable Chinese mainland 3 x 10 mm (red, blue and V-16070069-000 RG-PD1200 V2.00 or earlier yellow green) Rated current: 63A Terminal Connecting OT Terminal Connecting to Cable Appearance...
  • Page 115: Appendix F Site Selection

    Appendix F Site Selection  The machine room should be at least 5km away from the heavy pollution source such as the smelter, coal mine and thermal power plant, 3.7km away from the medium pollution source such as the chemical industry, rubber industry and electroplating industry, and 2km away from the light pollution source such as the food manufacturer and leather plant.