Electrical Characteristics; Table 4 Normal And Extreme Voltages; Table 5 Current Consumption - Nokia RM-305 Service Manual

Mobile terminal part no: 9200071 (issue 2)
Table of Contents

Advertisement

RM-305; RM-306
General information

Electrical characteristics

Voltage
Nominal voltage
Lower extreme voltage
Higher extreme voltage
Vmstr+
Vmstr-
SW shutdown
SW shutdown
Vcoff+
Vcoff-
Min
Max
a. The nominal voltage is defined as being 15% higher than the lower extreme voltage. TA will test with this
nominal voltage at an 85% range (0.85x3.9V
b. This limit is set to be above SW shutdown limit in TA.
c. During fast charging of an empty battery, this voltage might exceed this value. Voltages between 4.20 and
4.60 might appear for a short while.
d. The minimum battery cell voltage required for the reset circuitry to turn on. This is not confirmed by
measures at pt.
Condition
Call (MoU)
GSM 850
(E)GSM 900
GSM 1800
GSM 1900
Idle (MoU)
Power off
Issue 2

Table 4 Normal and extreme voltages

3.90V
3.30V
4.30V
HW shutdown voltages
2.1V ± 0,1V
1.9V ± 0,1V
SW shutdown voltages
3. 1V
3. 2V
Min operating voltage
3. 1V ± 0,1V
2. 8V ± 0,1V
1. 0V
--

Table 5 Current consumption

Min
25
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
Voltage (V)
General conditions
HW reset demands
a
3.3V).
Typical
.
225
208
188
168
2.0
30
Condition
a
b
c
Off to on
On to off
In call
In idle
Off to on
On to off
d
Max
45
Unit
mA
mA
µA
Page 1 –9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm-3061650