GE C30 Instruction Manual page 323

Controller system ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 39)
ADDR
REGISTER NAME
9013
FlexElement™ 1 Events
9014
...Repeated for FlexElement™ 2
9028
...Repeated for FlexElement™ 3
903C
...Repeated for FlexElement™ 4
9050
...Repeated for FlexElement™ 5
9064
...Repeated for FlexElement™ 6
9078
...Repeated for FlexElement™ 7
908C
...Repeated for FlexElement™ 8
90A0
...Repeated for FlexElement™ 9
90B4
...Repeated for FlexElement™ 10
90C8
...Repeated for FlexElement™ 11
90DC
...Repeated for FlexElement™ 12
90F0
...Repeated for FlexElement™ 13
9104
...Repeated for FlexElement™ 14
9118
...Repeated for FlexElement™ 15
912C
...Repeated for FlexElement™ 16
dcmA Outputs (Read/Write Setting) (24 modules)
9300
dcmA Output 1 Source
9301
dcmA Output 1 Range
9302
dcmA Output 1 Minimum
9304
dcmA Output 1 Maximum
9306
...Repeated for dcmA Output 2
930C
...Repeated for dcmA Output 3
9312
...Repeated for dcmA Output 4
9318
...Repeated for dcmA Output 5
931E
...Repeated for dcmA Output 6
9324
...Repeated for dcmA Output 7
932A
...Repeated for dcmA Output 8
9330
...Repeated for dcmA Output 9
9336
...Repeated for dcmA Output 10
933C
...Repeated for dcmA Output 11
9342
...Repeated for dcmA Output 12
9348
...Repeated for dcmA Output 13
934E
...Repeated for dcmA Output 14
9354
...Repeated for dcmA Output 15
935A
...Repeated for dcmA Output 16
9360
...Repeated for dcmA Output 17
9366
...Repeated for dcmA Output 18
936C
...Repeated for dcmA Output 19
9372
...Repeated for dcmA Output 20
9378
...Repeated for dcmA Output 21
937E
...Repeated for dcmA Output 22
9384
...Repeated for dcmA Output 23
938A
...Repeated for dcmA Output 24
Direct Input/Output Names (Read/Write Setting) (96 modules)
9400
Direct Input 1 Name
9406
Direct Output 1 Name
940C
...Repeated for Direct Input/Output 2
9418
...Repeated for Direct Input/Output 3
9424
...Repeated for Direct Input/Output 4
9430
...Repeated for Direct Input/Output 5
943C
...Repeated for Direct Input/Output 6
9448
...Repeated for Direct Input/Output 7
9454
...Repeated for Direct Input/Output 8
GE Multilin
RANGE
UNITS
0 to 1
0 to 65535
0 to 2
–90 to 90
–90 to 90
0 to 96
1 to 96
C30 Controller System
B.4 MEMORY MAPPING
STEP
FORMAT
---
1
F102
---
1
F600
---
1
F522
0 (–1 to 1 mA)
pu
0.001
F004
pu
0.001
F004
---
1
F205
---
1
F205
DEFAULT
0 (Disabled)
B
0
0
1000
"Dir Ip 1"
"Dir Out 1"
B-25

Advertisement

Table of Contents
loading