Siemens SIMATIC RF640T Gen 2 Operating Instructions Manual

Simatic sensors rfid systems

Advertisement

Quick Links

1
SIMATIC RF640T Gen 2
TAGnology RFID GmbH | Grazer Vorstadt 142 | 8570 Voitsberg | AUSTRIA
phone: +43 (0)3142/ 28 9 28-10 | fax: +43 (0)3142/ 28 9 28-20 | office@tagnology.com
|
www.tagnology.com
SIMATIC Sensors
RFID systems
SIMATIC RF640T Gen 2
Operating Instructions
05/2009
J31069-D0197-U001-A2-7618

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF640T Gen 2

  • Page 1 SIMATIC RF640T Gen 2 TAGnology RFID GmbH | Grazer Vorstadt 142 | 8570 Voitsberg | AUSTRIA phone: +43 (0)3142/ 28 9 28-10 | fax: +43 (0)3142/ 28 9 28-20 | office@tagnology.com www.tagnology.com SIMATIC Sensors RFID systems SIMATIC RF640T Gen 2...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents SIMATIC RF640T Gen 2 ........................... 5 Characteristics ..........................5 Ordering data ..........................6 Planning the use ..........................6 1.3.1 Optimum antenna/transponder positioning with plane mounting of the transponder on metal ..............................6 1.3.2 Reading range on flat metallic carrier plates .................7 1.3.3...
  • Page 4 Table of contents SIMATIC RF640T Gen 2 Operating Instructions, 05/2009, J31069-D0197-U001-A2-7618...
  • Page 5: Simatic Rf640T Gen 2

    SIMATIC RF640T Gen 2 Characteristics The SIMATIC RF640T Gen 2 transponder is a passive (i.e. battery-free) and maintenance- free, round-shaped data carrier. It functions based on the UHF Class 1 Gen 2 technology and is used for saving the electronic product code (EPC) of 96 bits/240 bits. The transponder also has a 512-bit user memory.
  • Page 6: Ordering Data

    SIMATIC RF640T Gen 2 1.2 Ordering data Ordering data Ordering data Order no. SIMATIC RF640T Gen 2 (Europe) 6GT2810-2DC00 Frequency 865 MHz to 868 MHz • EPC 96 bits/240 bits • 64-byte user memory • -25 °C to +85 °C operating temperature •...
  • Page 7: Reading Range On Flat Metallic Carrier Plates

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.2 Reading range on flat metallic carrier plates The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the tag is centrically mounted on a flat metal plate, which may either be almost square or circular, it can be aligned in any direction since the transmitting and receiving RF660A antennas operate with circular polarization.
  • Page 8: Reading Range When Mounted On Non-Metallic Carriers

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.3 Reading range when mounted on non-metallic carriers The transponder is generally designed for mounting on metallic objects which provide the conditions for the maximum reading ranges Table 1- 2 Reading range on non-metallic carriers...
  • Page 9: Influence Of Conducting Walls On The Reading Range

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.4 Influence of conducting walls on the reading range If there are conducting walls or restrictions in the vicinity that could shade the radio field, a distance of approx. 10 cm is recommended between the transponder and the wall In principle, walls have least influence if the polarization axis is orthogonal to the conducting wall.
  • Page 10: Directional Radiation Pattern Of The Transponder

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.5 Directional radiation pattern of the transponder Preferably, align the tag parallel to the transmitting antenna. If, however, the tag including the metallic carrier plate is tilted, the reading range will be reduced.
  • Page 11: Use Of The Transponder In Hazardous Areas

    SIMATIC RF640T Gen 2 1.3 Planning the use Rotation orthogonal to the polarization axis Figure 1-4 Transponder characteristics when rotated orthogonally to the polarization axis (within the tag plane) 1.3.6 Use of the transponder in hazardous areas TÜV NORD CERT GmbH, appointed center no. 0044 as per Article 9 of the Directive...
  • Page 12: Use Of The Transponder In Hazardous Areas For Gases

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.7 Use of the transponder in hazardous areas for gases Temperature class delineation for gases The temperature class of the transponder for hazardous areas depends on the ambient temperature range: Ambient temperature range Temperature class -25 °C to +85 °C...
  • Page 13: Use Of The Transponder In Hazardous Areas For Dusts

    SIMATIC RF640T Gen 2 1.3 Planning the use 1.3.8 Use of the transponder in hazardous areas for dusts The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are higher than 210 °C (smoldering temperature). With the ignition temperature specified according to IEC 61241-0 and IEC 61241-11 according to the type of ignition protection iD, the smoldering temperature of the dust layer is referenced in this case.
  • Page 14: Mounting Instructions

    SIMATIC RF640T Gen 2 1.4 Mounting instructions Mounting instructions Properties Description Type of installation Screw mounting ①, (M4 screws) (two DIN 433 washers and two M4 hexagon socket head cap screws DIN 6912) Tightening torque (at room temperature) < 1.2 Nm...
  • Page 15: Memory Configuration

    SIMATIC RF640T Gen 2 1.5 Memory configuration Memory configuration SIMATIC memory configuration The following graphic shows the structure of the virtual SIMATIC memory for the RF620R/RF630R reader and explains the function of the individual memory areas. The SIMATIC memory configuration is based on the 4 memory banks, as they are defined in EPC Global.
  • Page 16 SIMATIC RF640T Gen 2 1.5 Memory configuration Memory representation for RF640T Gen 2 Tags User RESERVED special [hex] (passwords) Range Access KILL-PW Lock function RF640T 00 - 3F FF00-FF0B read/ FFC0-FFC7 FF80-FF87 LOCKED Gen 2 (240 Bit = write FF00-FF1D)
  • Page 17 SIMATIC RF640T Gen 2 1.5 Memory configuration The graphic below illustrates the exact memory utilization: Each box in the right part of the graphic represents one word (16 bit) in the memory. Color Access by SIMATIC RF660R / SIMATIC RF610M...
  • Page 18: Technical Specifications

    SIMATIC RF640T Gen 2 1.6 Technical Specifications Technical Specifications 1.6.1 Mechanical data Property Description Dimensions (D x H) 50 mm x 8 mm (+1 mm) Construction PCB with integrated antenna Design Plastic housing (PA12) Weight approx. 13 g Mounting on metal directly on metal without spacing 1.6.2...
  • Page 19: Memory Specifications

    SIMATIC RF640T Gen 2 1.6 Technical Specifications 1.6.3 Memory specifications Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 64 bytes 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time...
  • Page 20: Chemical Resistance Of The Rf640T Gen 2 Transponder

    SIMATIC RF640T Gen 2 1.6 Technical Specifications The values for shock and vibration are maximum values and must not be applied continuously. WARNING Ignitions of gas-air or dust-air mixtures When using the RF640T transponder, check to ensure that the temperature values are observed in respect of the requirements of the hazardous area of application.
  • Page 21 SIMATIC RF640T Gen 2 1.6 Technical Specifications Concentration 20 °C 60 °C ○○○○ ○○○ Formalin ○○○ ᅳ Glycerine ○○○○ ○○○○ Hydrochloric acid ○ ᅳ Hydrogen sulphide ○○○○ ○○○○ Iron salts, w. k. g. ○○○○ ○○○○ Isopropanol ○○○○ ○○○ Lactic acid, w.
  • Page 22: Certificates And Approvals

    SIMATIC RF640T Gen 2 1.7 Certificates and approvals Certificates and approvals 1.7.1 Certificates and approvals Table 1- 3 6GT2810-2DC00 - RF640T Gen 2 UHF Tool Tag - Europe Certificate Description CE Approval to R&TTE directive For Directive 94/9/EC: EC type test certification no. TÜV 07 ATEX 346241 Acknowledgement of the quality assurance TÜV 96 ATEX 1125 Q...
  • Page 23: Dimension Drawing

    SIMATIC RF640T Gen 2 1.8 Dimension drawing Dimension drawing Figure 1-8 SIMATIC RF640T Gen 2 UHF Tool Tag Version 1 Units of measurement: All dimensions in mm SIMATIC RF640T Gen 2 Operating Instructions, 05/2009, J31069-D0197-U001-A2-7618...
  • Page 24 SIMATIC RF640T Gen 2 1.8 Dimension drawing SIMATIC RF640T Gen 2 Operating Instructions, 05/2009, J31069-D0197-U001-A2-7618...