Measurement Setup - Philips CED230 Service Manual

Hide thumbs Also See for CED230:
Table of Contents

Advertisement

MEASUREMENT SETUP

Tuner FM
RF Generator
e.g. PM5326
Use a bandpass filter to eliminate hum(50Hz,100Hz) and disturbance from the pilottone(19kHz,38kHz).
Tuner AM (MW,LW)
RF Generator
e.g. PM5326
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday s cage.
Use a bandpass filter ( or at least a high pass filter with 250Hz) to eliminate hum ( 50Hz,100Hz ).
CD
Use Audio Signal Disc SBC429 4822 397 30184
(replaces test disc 3)
DUT
L
R
Bandpass
DUT
250Hz-15kHz
e.g. 7122 707 48001
Bandpass
250Hz-15kHz
DUT
e.g. 7122 707 48001
Frame aerial
e.g. 7122 707 89001
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
1-3
LF Voltmeter
e.g. PM2534
S/N and distortion meter
e.g. Sound Technology ST1700B
LF Voltmeter
e.g. PM2534
S/N and distortion meter
e.g. Sound Technology ST1700B
Cassette
Use Universal Test Cassette CrO2 SBC419 4822 397 30069
or Universal Test Cassette Fe
LF Generator
e.g. PM5110
'
SBC420 4822 397 30071
DUT
L
R
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter

Advertisement

Table of Contents
loading