Server Startup and Power Supply Control Notes

3.4
Server Startup and Power Supply Control Notes
Before turning the server on, check that the ETERNUS DX storage systems and SAS Channel switches are all
"Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize the
ETERNUS DX storage systems.
Also, when the ETERNUS DX power supply is being controlled by a UPS power supply linkage, make sure that
the ETERNUS DX is never turned off before the connected servers. If turned off, data writes from the running
server cannot be saved to the ETERNUS DX storage systems, and already saved data may also be affected.
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Citrix
Copyright 2017 FUJITSU LIMITED