Cable Lengths - Siemens SCALANCE MM900 Compact Operating Instructions

Industrial ethernet switches
Hide thumbs Also See for SCALANCE MM900:
Table of Contents

Advertisement

Technical data

5.3 Cable lengths

You will find further information in the compact operating instructions "Transceiver
1)
SFP/SFP+".
The ports of the MM992-2M12 (C) only meet the requirements according to Environment A
2)
(IEEE 802.3), in other words, the electrical isolation of the ports is designed for 500 Vrms (1
minute).
5.3
Cable lengths
Copper cables
Table 5- 10
Media module
MM992-2CUC
MM992-2CUC (C)
MM992-2CU
MM992-2M12 (C)
MM992-2VD (without
VD)
MM992-2VD (with VD)
The VD mode (Variable Distance) is turned off.
1)
The VD mode (Variable Distance) is turned on.
2)
38
Permitted cable lengths (copper cable - Fast Ethernet)
Cable
IE TP torsion cable with
IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
IE FC TP marine/trailing/flexible cable
1)
with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP marine/trailing/ flexible cable
with IE FC RJ-45 Plug 180
IE FC TP standard cable with
IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 plug 180
IE FC TP standard cable GP 4X2 (24
2)
AWG) with IE FC RJ-45 plug 4x2
IE FC TP standard cable GP 2x2
with IE FC RJ-45 plug 2x2
IE FC TP standard cable GP 2x2
with IE FC RJ-45 plug 2x2
PROFIBUS FC standard cable GP
with IE FC RJ-45 plug 4x2
PROFIBUS FC standard cable GP
with IE FC RJ-45 plug 4x2
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
0 to 500 m at 100 Mbps
0 to 300 m at 100 Mbps.
300 to 500 m at 10 Mbps
100 to 1000 m at 10 Mbps
0 to 100 m at 100 Mbps.
Compact Operating Instructions, 05/2016, A5E02630805-12
SCALANCE MM900

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net