Installation Instructions

Connection, Switch-Point control, Address Switches

Connection
Make sure the control panel is disconnected from the power supply.
!
Connect the control unit and the optional components
as shown in the connection diagram on the following page.
Switch-point control
(18 C point): a freely programmable C-point switch output (open-collector output) 12 V, max. 80
mA, is located on the control unit. Connect only one cable with a maximum length of 3 m.
The yellow LED on the SmartKey code keypad is connected to the C-point by default. An appro-
priate series resistor is fitted to enable the C-point to be connected to the yellow LED on the
SmartKey code keypad. Solder a bridge across the solder points on BR2 (circuit board reverse)
to bridge the series resistor if the C-point is used for a different purpose and not connected to the
yellow LED on the SmartKey code keypad.
Address switch
The address switch is used for LSN panels in the planning stage.
The address switch does not need to be adjusted on any of the currently available LSN panels.
The address switch should remain in the positions CL 0 0. Default setting.
Preliminary information on the address switch:
CL 0 0
= "Classic" LSN mode (standard setting)
001 – 254
= LSNi mode with manual addressing of the control unit
0 0 0
= LSNi mode with automatic addressing of the control unit
The control unit address is set by positioning the three rotatable switches. Use a flat-head screw-
driver to adjust each switch. The switches will click when turned. The valid range is from 1 to
254. Any settings between 255 and 299 will cause an error message to be displayed on the con-
trol panel.
0
0
CL
1
1
9
2
2
8
3
7
4
6
5
Setting in Hundreds Tens
10
0
1
9
2
8
3
7
4
6
5
Units