Electrolux Premium Quick Reference Manual page 19

Thermoregulator management controller
Table of Contents

Advertisement

accensione strumento
power ON
richiesta di intervento
insertion request
compressore
compressors
C0
Fig. 7.d
richiesta inserimento
insertion request
compressore
compressors
C1
Fig. 7.e
richiesta inserimento
insertion request
compressore
compressors
Fig. 7.f
richiesta inserimento
insertion request
compressore
compressors
C3
Fig. 7.g
C4
compressore
compressors
OFF = 15 min.
Fig. 7.h
From ser. no.:
7.3 Compressor management parameters
ON
OFF
ON
Code
c0
OFF
ON
c1
c2
OFF
c3
c4
cc
c6
c7
ON
c8
c9
OFF
c10
ON
c11
OFF
c0: Compressor and fan start delay (if 'FAN' relay present) on start-up
When the controller is switched on, the compressor and the evaporator fans and the auxiliary relay in control with dead band (H1 or
H5=11) start after a delay (in minutes) equal to the value set for this parameter, in order to protect the compressor against repeated
power-ups in the event of frequent power drops. Default: c0=0 => no minimum delay is set.
Example:
ON
with more than one compressor, the parameter c0 can also be used to avoid simultaneous starts of a series of units. Simply set
OFF
a diff erent value of c0 for each compressor.
ON
associated with the timers ' c 0' , ' c 1' , ' c 2' , ' c 3' .
OFF
c1: Minimum time between two successive starts of the compressor
C2
Sets the minimum time (in minutes) that must elapse between two starts of the compressor, irrespective of the temperature and the
set point. Setting this parameter limits the number of starts per hour.
Default: c'=0 => no minimum time is set between two starts.
Example:
the second compressor step, for the aux 1 or 2 output ('H1 or H5'=12, 13), is associated with the timers ' c 0' , ' c 1' , ' c 2' , ' c 3' .
ON
OFF
c2: Minimum compressor OFF time
ON
SSets the minimum time (in minutes) for the compressor to remain OFF. The compressor is not started again until the minimum
OFF
time selected (c2) has elapsed from when it last stopped.
Note: this parameter is useful to ensure the balancing of the pressure after the compressor stops for systems with hermetic and
capillary compressors. The second compressor step, for the aux 1 or 2 output ('H1 or H5'=12, 13), is associated with the timers
' c 0' , ' c 1' , ' c 2' , ' c 3' .
c3: Minimum compressor ON time
Sets the minimum running time for the compressor. The compressor is not stopped until it has been ON for at least the minimum
time selected (c3).
ON
' c 0' , ' c 1' , ' c 2' , ' c 3' .
Default: c3=0 => no minimum running time is set.
OFF
c4: Duty setting
If the virtual control probe fault alarm occurs (see parameter '/4'), this parameter is used to ensure the operation of the compres-
sor until the fault is resolved.
Default: c4=0 => compressor always Off in the event of a virtual control probe error.
Important:
Duty Setting is not activated.
In practice, as the compressor is no longer able to operate based according to the temperature (due to the probe fault), it is made
to run cyclically with an operating time (ON time) equal to the value assigned to parameter c4 (in minutes) and a fi xed OFF time
of 15 minutes.
There are two values of c4 that cause special behaviour:
c4=0, in the event of faults involving the virtual control probe, the compressor is always OFF;
c4=100, the compressor is always ON, that is, the 15 minute OFF time is always ignored.
Special situations:
• if the virtual control probe error occurs while the compressor is OFF, it remains OFF for 15 minutes, and is then started
• if the virtual control probe error occurs while the compressor is ON, it remains ON for the time c4, and then is stopped (without
Warning:
Note:
both steps.
Page:19
Parametro
Compressor, fan and AUX start delay on power up in dead zone
Minimum time between successive starts
Minimum compressor OFF time
Minimum compressor ON time
Duty setting
Continuous cycle duration
Alarm bypass after continuous cycle
Maximum pump down time
Comp. start delay after open PD valve
Enable autostart function in PD
Select pump down by time or pressure
Second compressor delay
setting c0=6 forces the compressor to wait 6 minutes before starting from when power returns. In the event of systems
Note:
the second compressor step, for the aux 1 or 2 output ('H1 or H5'=12, 13), is
if the maximum number of activations/hour allowed is 10, simply set c1=6 to ensure that this limit is respected. Note:
Note:
the second compressor step, for the aux 1 or 2 output ('H1 or H5'=12, 13), is associated with the timers
In the event of errors on probe 2, the virtual probe corresponds to the room probe (probe 1) and consequently the
(respecting the times set for parameters c1 and c2) and remains ON for a time equal to c4, Duty Setting. This special operation is
signalled by the LED that fl ashes during the compressor OFF period, and remains on steady when the compressor is operating.
The fans continue to operate according the set parameters (see F parameters). If the duty setting requires the immediate shut-
down of the compressor for a non-specifi ed time (c4= 0), this is done without observing the compressor protection times.
observing the minimum ON time, if set for parameter c3) and remains OFF for 15 minutes (the LED fl ashes in this phase).
After this, cyclical operation starts, with an operating time equal to the value of c4.
If the virtual probe error disappears, the unit returns to normal operation.
if control with two compressor steps is selected (with or without rotation, 'H1 or H5'= 12 or 13), the duty setting acts on
Ed.1" 08-2014
Models
U.M. Type Min
-SYF
min
C
0
-SYF
min
C
0
-SYF
min
C
0
-SYF
min
C
0
-SYF
min
C
0
-SYF
hours
C
0
-SYF
h/min
C
0
-SYF
s
C
0
-SYF
s
C
0
-SYF
fl ag
C
0
-SYF
fl ag
C
0
-SYF
s
C
0
560001 EG
Doc. No.:
Max
Def.
15
0
15
0
15
0
15
0
100
0
15
0
250
2
900
0
60
5
1
0
1
0
250
4
Tab. 7.d