6. Capacity table
6-1. Combinations
Model: AOU24RLXFZH
Cooling
1) Non-ducted
Combination of indoor unit
Room 1
Room 2
Room 3
Total
7
7
-
14
7
9
-
16
7
12
-
19
7
15
-
22
7
18
-
25
9
9
-
18
9
12
-
21
9
15
-
24
9
18
-
27
12
12
-
24
12
15
-
27
7
7
7
21
7
7
9
23
7
7
12
26
7
9
9
25
9
9
9
27
2) Ducted
Combination of indoor unit
Room 1
Room 2
Room 3
Total
7
7
-
14
7
9
-
16
7
12
-
19
7
18
-
25
9
9
-
18
9
12
-
21
9
18
-
27
12
12
-
24
7
7
7
21
7
7
9
23
7
7
12
26
7
9
9
25
9
9
9
27
NOTES:
Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h, 15: 14,000 Btu/h, 18: 18,000 Btu/h
• 2 or more indoor units should be connected.
• Cooling: Indoor temperature of 80 °FDB (26.7 °CDB)/ 67 °FWB (19.4 °CWB), and outdoor
temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
• The total ability of connected indoor units is from 14,000 Btu up to 27,000 Btu.
• Non-Ducted system combinations input are based on ASU wall mount models. The input of
combinations including AUU cassette models may be a little higher.
• Ducted system combinations capacities are based on ARU slim duct units excepting 7,000-Btu
models. 7,000 Btu models are based on ASU wall mount models.
Rated capacity for each indoor
Maximum capacity for each
unit (kBtu/h)
Room 1
Room 2
Room 3
Room 1
7.05
7.05
-
8.70
7.09
9.11
-
8.66
7.07
12.13
-
8.33
6.87
13.73
-
8.05
6.16
15.84
-
7.20
9.00
9.00
-
10.75
9.00
12.00
-
10.11
8.41
13.09
-
9.70
7.33
14.67
-
8.67
11.00
11.00
-
12.50
10.15
11.85
-
12.46
7.00
7.00
7.00
8.57
6.70
6.70
8.61
8.22
5.92
5.92
10.15
7.27
6.16
7.92
7.92
7.56
7.33
7.33
7.33
9.00
Rated capacity for each indoor
Maximum capacity for each
unit (kBtu/h)
Room 1
Room 3
Room 2
Room 1
7.05
7.05
-
8.70
7.09
9.11
-
8.66
7.07
12.13
-
8.33
6.16
15.84
-
7.20
9.00
9.00
-
10.75
9.00
12.00
-
10.11
7.33
14.67
-
8.67
11.00
11.00
-
12.50
7.00
7.00
7.00
8.57
6.70
6.70
8.61
8.22
5.92
5.92
10.15
7.27
6.16
7.92
7.92
7.56
7.33
7.33
7.33
9.00
- 185 -
Total capacity
indoor unit (kBtu/h)
(kBtu/h)
Room 2
Room 3
Min.
Rated
8.70
-
6.10
14.10
11.14
-
6.10
16.20
14.27
-
6.10
19.20
16.10
-
6.10
20.60
18.50
-
6.10
22.00
10.75
-
6.10
18.00
13.49
-
6.10
21.00
15.10
-
6.10
21.50
17.33
-
6.10
22.00
12.50
-
6.10
22.00
14.54
-
6.10
22.00
8.57
8.57
6.10
21.00
8.22
10.57
6.10
22.00
7.27
12.46
6.10
22.00
9.72
9.72
6.10
22.00
9.00
9.00
6.10
22.00
Total capacity
indoor unit (kBtu/h)
(kBtu/h)
Room 3
Room 2
Min.
Rated
8.70
-
6.10
14.10
11.14
-
6.10
16.20
14.27
-
6.10
19.20
18.50
-
6.10
22.00
10.75
-
6.10
18.00
13.49
-
6.10
21.00
17.33
-
6.10
22.00
12.50
-
6.10
22.00
8.57
8.57
6.10
21.00
8.22
10.57
6.10
22.00
7.27
12.46
6.10
22.00
9.72
9.72
6.10
22.00
9.00
9.00
6.10
22.00
Input power (kW)
Max.
Min.
Rated
Max.
17.40
0.50
1.13
1.45
19.80
0.50
1.29
1.73
22.60
0.50
1.53
1.97
24.15
0.50
1.65
2.30
25.70
0.50
1.72
2.38
21.50
0.50
1.42
1.86
23.60
0.50
1.66
2.04
24.80
0.50
1.71
2.35
26.00
0.50
1.71
2.43
25.00
0.50
1.74
2.30
27.00
0.50
1.74
2.43
25.70
0.50
1.62
2.17
27.00
0.50
1.65
2.20
27.00
0.50
1.65
2.43
27.00
0.50
1.65
2.43
27.00
0.50
1.65
2.43
Input power (kW)
Max.
Min.
Rated
Max.
17.40
0.50
1.24
1.59
19.80
0.50
1.40
1.77
22.60
0.50
1.72
2.10
25.70
0.50
2.01
2.48
21.50
0.50
1.63
2.02
23.60
0.50
1.81
2.20
26.00
0.50
2.01
2.48
25.00
0.50
2.00
2.45
25.70
0.50
1.80
2.28
27.00
0.50
1.81
2.29
27.00
0.50
1.81
2.48
27.00
0.50
1.81
2.48
27.00
0.50
1.81
2.48