5. Troubleshooting Guide

TROUBLESHOOTING GUIDE
Symptom
1,The machine's power supply is
Without
abnormal.
Energization
2,The PCB assembly may fail.
1,Is the room ventilated,or has laid the
The humidity
carpet onto the floor.
does not
increase
The motor does
1,The motor assembly may fail.
not operate or
speed is lower
2,The component on the PCB is
than normal
levels
Polluted air is
1,Is the C.Filter assembly dirty.
difficult to be
removed
Even if there is
1,Is the tray fit into the interior of the
water in the
tank,the water
fill indicator is
2,Is the product tilted.
still blinking or
lit up.
1,Infrared Circuit assembly without
Remote control
does not work
2,The remote control assembly may fail.
3,The battery may be exhausted.
Cause
abnormal.
product.
electricity.
Troubleshooting
1, Check the power supply status and
check if the related wiring connection is
loosed.
2,Replace the PCB assembly.
1,If the floor is carpeted,the humidity may
be difficult to increase sometimes,
depending on the specific ventilation,
floor and wall material.
1,Replace the motor assembly.
2,Replace the PCB assembly.
1,Clean it.If the symptoms persist,replace
the filter a new one.
1, Fixing the tray into the interior of the
product.
2,Please install the product onto the level
and stable table or floor.
1,Check the Infrared Circuit assembly
wiring connection.
2,Replace the remote control assembly.
3,Replace the battery.