Alarm Troubleshooting
Clear the INTRUSION-PSWD Condition
In node view, click the Provisioning > Security tabs.
Step 1
Click Clear Security Intrusion Alarm.
Step 2
If the condition does not clear, log into the Technical Support Website at
Step 3
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.105 INVMACADR
The Equipment Failure Invalid MAC Address alarm occurs when the ONS 15310-MA SDH MAC
address is invalid. The MAC Address is permanently assigned to the chassis when it is manufactured.
Do not attempt to troubleshoot an INVMACADR alarm. Log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.106 IOSCFGCOPY
The IOS Configuration Copy in Progress condition occurs on ML-100T-8 Ethernet cards when a
Cisco IOS startup configuration file is being uploaded or downloaded to or from an ML-100T-8 Ethernet
card. (This condition is very similar to the
ML-100T-8 Ethernet cards rather than to the controller card.)
The condition clears after the copy operation is complete. (If it does not complete correctly, the
"NO-CONFIG" condition on page 2-111
IOSCFGCOPY is an informational condition.
Note
For more information about the Ethernet cards, refer to the Cisco ONS 15310-CL and
Note
Cisco ONS 15310-MA Ethernet Card Software Feature and Configuration Guide.
2.7.107 ISIS-ADJ-FAIL
78-18663-01
Default Severity: Major (MJ), Service-Affecting (SA)
SDH Logical Object: BPLANE
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: EQPT
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SDH Logical Object: STM
"SFTWDOWN" condition on page 2-127
could be raised.)
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
Alarm Procedures
but it applies to