Summary of Contents for Huawei HES-319M

  • Page 1 HES-319M Installation Version: 1.1 Publication Date: 12-Apr–13...
  • Page 2: Table Of Contents

    Removed WMI URLs and login credentials. Contents 1. Overview .............................. 4 2. Introduction to the HES-319M ......................5 Comparison: HES-319M, BreezeMAX PRO 3000, BreezeMAX PRO 6000 ............5 HES-319M: As Shipped ............................7 HES-319M ODU ..............................8 HES-319M ODU Signal Strength Indicators ......................9 HES-319M IDU ..............................
  • Page 3 5. Aligning the HES-319M ........................31 Rescanning for Base Stations ..........................32 Quality of Installation Parameters ........................34 Alignment and Acceptance ..........................35 Identifying the Base Station ..........................38 6. Connecting Your Customer’s Computer to the CPE ................39 HES-319M Installation...
  • Page 4: Overview

    1. Overview The HES-319M Installation guide provides material specific to the HES-319M for Installers of Xplornet WiMAX services. It must be used in conjunction with the WiMAX Customer Premise Equipment Installation guide. Refer to the WiMAX Customer Premise Installation guide for information on: ...
  • Page 5: Introduction To The Hes-319M

    WiMAX CPEs are quite similar and familiarity with one helps you when starting up with another. The following table compares the BreezeMAX PRO 3000, BreezeMAX PRO 6000, and HES-319M to provide a starting point for those familiar with the BreezeMAX PRO CPEs and new to the HES-319M.
  • Page 6 LEDs at ODU (CINR) LEDs at ODU (RSSI) QoI Levels Telephone tones (CINR) WMI (CINR and RSSI) WMI (CINR and RSSI) Activation The same for all except there is a firmware upgrade (Installer Portal) process with the BreezeMAX PRO 3000. HES-319M Installation...
  • Page 7: Hes-319M: As Shipped

    HES-319M: As Shipped The HES-319M CPE is shipped in one box that contains:  The outdoor unit (A), or ODU, with sealing gland assembly (B)  The indoor unit (C), or IDU, with AC power cord (D)  A 6ft–1.8m Ethernet cable (E) ...
  • Page 8: Hes-319M Odu

     Signal Strength LEDS (C): o Five LEDs indicate the strength of the signal received from the base station. Refer to the next topic, HES-319M ODU Signal Strength Indicators, for details. o Weather–sealed with the LED cap (D)  Ground screw (E): Used to connect the ODU to an approved building ground point.
  • Page 9: Hes-319M Odu Signal Strength Indicators

    HES-319M ODU Signal Strength Indicators The HES-319M ODU has LEDs that indicate the RSSI (Received Signal Strength Indicator) of the signal from the base station. You use the signal strength indicators when you align the ODU; details are provided in the chapter, Aligning the HES-319M.
  • Page 10: Hes-319M Idu

    HES-319M IDU The HES-319M IDU is a Power over Ethernet, or PoE, adapter that is powered from the AC mains. It provides the communications interface between your customer’s computing equipment and the ODU, and supplies power to the ODU. The PoE adapter has two ports and three LEDs: ...
  • Page 11: Static Ip Addresses

    Static IP Addresses Static IP addresses are not supported on the HES-319M. If you are planning to install an HES-319M, be sure your customer has not ordered a static IP address – before you leave for the site. HES-319M Installation...
  • Page 12: Base Station Restrictions

    Base Station Restrictions The HES-319M operates in the 3,400MHz to 3,600MHz range and cannot be used with base stations that operate above 3,600MHz. The WiMAX Base Station ID list available from the Xplornet University WiMAX library shows the base stations that can communicate with the HES-319M.
  • Page 13: Mounting The Hes-319M Odu

    The mounting kit can be used with masts/poles whose diameter ranges in size from 1 to 2.5in–2.5 to 6.4cm.  You need the grounding kit (wire and screw) that was shipped with the HES-319M or equivalent.  To ensure weather–protection, mount the ODU so that the side with the RJ-45 port faces down.
  • Page 14 If the -15° flange is up, feed the U-bolt through the top holes for a parallel mount. 3. Spin an M6 nut on each arm of the U-bolt. 4. Move the kit to the desired position on the pole and tighten the nuts. HES-319M Installation...
  • Page 15 8. Thread the screw provided with the grounding kit through one of the ring lugs on the ground wire and into the threaded hole on the back of the ODU just below the ground symbol. 9. Tighten the screw. HES-319M Installation...
  • Page 16: Other Mounting Options

    Other mounting options Alternate mounting options are illustrated below. Note which flange is up (+15° or –15°) and which holes the U-bolt goes through (upper or lower). HES-319M Installation...
  • Page 17: Installing Cables And Grounds For The Hes-319M

    4. Installing Cables and Grounds for the HES-319M The diagram illustrates the wiring plan for the HES-319M. The tasks you need to carry out to complete the wiring plan are listed below. Detailed instructions for each task are provided in following topics.
  • Page 18 10. Install a Cat5e cable between the surge suppressor and the IDU. 11. Install the supplied Ethernet cable between the IDU and your computer. 12. Plug in the IDU and power up your computer. When all tasks are complete, you are ready to align the ODU. HES-319M Installation...
  • Page 19: Approved And Unacceptable Building Ground Points

    A cut–off switch or a condensation pipe on a Heating Ventilation Air Conditioning, or HVAC, system  Steel roof trusses  Metal roofs, metal roof screws, metal screens, or metal windows  Vents or vent pipes  Electrical outlets or light fixtures  Gas pipes, gutters, exterior water faucets, unlicensed ground rods HES-319M Installation...
  • Page 20: Shaving The Rj-45 Connector Boot On The Cat5E Poe Cable

    2. If the cable cannot pass through, shave the corners of the boot. Be careful not to break the connector tab or shave the connector. It is much easier to shave the connector when the connector is warm, for example at room temperature rather than at winter temperatures. HES-319M Installation...
  • Page 21: Connecting The Surge Suppressor To The Building Ground

    3. Fasten the surge suppressor to a solid surface, as close to the planned point of entry as possible. Ensure that the side with the cable grommets faces down. 4. Reinstall the circuit board. 5. Remove the rubber cable grommets and make a small vertical and horizontal slit in each, then reinstall the grommets. HES-319M Installation...
  • Page 22 11. Loosen the nut and wrap the stripped wire clockwise around the brass post, between the two brass washers. The surge suppressor ships with a ring wiring lug on each ground terminal. You can leave these in place or discard them, but do not use them. 12. Tighten the nut. HES-319M Installation...
  • Page 23: Installing Cable & Ground From Surge Suppressor To Odu, Part 1

    Measure the distance between the surge suppressor and ODU and select the cable with the best fit. Measure along horizontal and vertical paths, but avoid sharp bends. Cutting and re–terminating the Cat5e cable is not allowed. 2. At the surge suppressor, separate a few inches of the integrated ground wire from the Cat5e cable. HES-319M Installation...
  • Page 24 However, it is often easier to wait until after you have aligned the ODU. Until then, plug the Cat5e cable directly into the ODU RJ-45 port. 13. When you are ready to reinstall the sealing gland assembly: a. Unplug the cable from the ODU RJ-45 port. HES-319M Installation...
  • Page 25 Push the rubber bushing along the cable until it is firmly seated in the sealing gland base. g. Install the sealing gland nut. Hand-tighten firmly: you are sealing the unit. 14. Continue to Part 2 of this procedure which covers installation of the ground wires at the ODU. HES-319M Installation...
  • Page 26: Installing Cable & Ground From Surge Suppressor To Odu, Part 2

    If you are not using the supplied ground wire, run Xplornet–approved 12AWG ground wire from the ground screw on the ODU to one of the terminals on the dual ground lug, or to the upper ground strap. 17. Tighten the screws at both ends to secure the wire. HES-319M Installation...
  • Page 27 20. Insert the stripped wire into the unused terminal of the dual ground lug, or in the terminal of the lower ground strap. 21. Tighten the terminal screw. 22. Secure the Cat5e cable and ground wire to the mounting platform using cable ties every 6in–15cm. HES-319M Installation...
  • Page 28: Installing Cable From Surge Suppressor To Idu

    3. Run the cable to the point of entry, creating a U–shaped drip loop at the point of entry. 4. Feed the cable through the point of entry and on to the IDU location identified by the customer. HES-319M Installation...
  • Page 29 24in–60cm to secure the cable to the building. 5. Coil excess cable inside the building, in an out–of–the–way location, preferably out of sight. 6. Unpack the IDU, place it in location, and plug the Cat5e cable into the port labelled "OUT". HES-319M Installation...
  • Page 30: Connecting To A Computer And Power

    1. Plug one end of the supplied Ethernet cable into the RJ–45 port on the IDU labelled "IN". 2. Plug the other end into the Ethernet port on your computer. 3. Plug the power cord into the IDU and a 120VAC power source. 4. Power up your computer. You are ready to align the ODU. HES-319M Installation...
  • Page 31: Aligning The Hes-319M

    5. Aligning the HES-319M This chapter explains how to align the HES-319M with a base station and verify that the signal quality is within acceptable limits. Always rescan for base stations before starting alignment. HES-319M Installation...
  • Page 32: Rescanning For Base Stations

    You can force a rescan by:  Powering down the ODU  Rebooting the CPE through the Web Management Interface (WMI). To force a rescan through the WMI, refer to the Alignment and Acceptance procedure, later in this chapter HES-319M Installation...
  • Page 33 Disconnect the PoE Cat5e cable from the RJ-45 port at the ODU. (c) 2. Wait 10 seconds, then restore power. The CPE performs a rescan. Wait about two minutes for the CPE to reconnect with a base station. HES-319M Installation...
  • Page 34: Quality Of Installation Parameters

    Program and Rate Plan. You need to find your customer’s Rate Plan in the QoI appendix now. WiMAX Program Name Channel Bandwidth QoI Parameter Rate Rate Rate Rate Plan 1 Plan 2 Plan 3 Plan 4 Minimum DL RSSI Level (dBm) Maximum DL RSSI Level (dBm) Minimum DL CINR Level (dB) HES-319M Installation...
  • Page 35: Alignment And Acceptance

    When you have configured your computer for DHCP: 1. Have the applicable QoI levels available, as well as the URL and login credentials of the HES-319M WMI.. 2. At the ODU, point the ODU along the line of sight to the base station you chose during your site survey.
  • Page 36 17. Compare the Signal Strength and Link Quality levels with the minimum acceptable levels for the rate plan to which your customer has subscribed. Remember to select the QoI table with the correct channel bandwidth. HES-319M Installation...
  • Page 37 Do not rotate the ODU to the side to reduce RSSI as this can cause interference with neighbouring base stations or CPE. Once you have acceptable levels, refer to the WiMAX Customer Premise Equipment Installation course or guide for instructions on activating the service. HES-319M Installation...
  • Page 38: Identifying The Base Station

    The seventh to tenth digits identify the site. The last two digits identify the sector. Digits can be letters or numbers. 6. Download and open the Base Station ID list from the Xplornet University Library. 7. Scan the BSID column until you find the BSID. HES-319M Installation...
  • Page 39: Connecting Your Customer's Computer To The Cpe

    3. At the computer, open a web browser. 4. In the browser address bar, enter the URL of the WMI. The WMI login window opens. 5. Enter the WMI Username and Password. (Login as a guest.) 6. Click OK. The System Status window opens. HES-319M Installation...
  • Page 40 For examples, try cbc.ca or ctv.ca. If you can surf, you are done. If you cannot, and you are not familiar with relevant troubleshooting procedures, refer the customer to Xplornet Technical Support: 1-866-841-6001; support@xplornet.com. HES-319M Installation...