Electrolux IC44819FFS Installation Manual page 38

Feeder ironer folder & stacker
Table of Contents

Advertisement

05102004
0308
Notice
Date
The machine is adjusted at the plant to be suitable for the kind of gas specified on the order.
If you have to supply your machine with gas in a family different from the gas for which your
machine was adjusted, proceed as follows :
Check that the diameter of the injectors is adequate for the kind of gas of your installation (see
table of injectors). The machine is delivered with extra injectors in a plastic envelope.
Testing pressures
According to the EN 437 standard, the values of the testing pressures mentioned in our various
documents are values for static pressures taken at the gas inlet connection of the machine; the
heating of the machine being on.
Changing to a gas in the same family
(type H or L)
- Adjust the gas outlet pressure (see
correspondence in the tables).
Changing to a gas in a different
family (from type H or L to butane or
propane)
- Change the 3 injectors with joints (see
correspondence in the tables).
- Unscrew the fixing screws (V) and remove
the adjusting head (J) as well as its cork
(T), keep these parts in case a change
would be necessary.
- Replace it by the cork (L) and the plate (P).
- Screw the two screws and block.
Changing to a gas in a different family (from butane or propane to type H or L)
- Change the 3 injectors with joints (see correspondence on the tables).
- Unscrew the fixing screws (V) and remove the plate (P) as well as the cork (L), keep these
parts in case a change would be necessary.
- Set the cork (T) and the adjustment head (J).
- Screw the two screws (V) and block.
17
7
Page
7. Installation
INSTALLATION
MANUAL
D0291

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic44825ffsIc44832ffs

Table of Contents