  • Page 1 300S Softlight 3100K/5600K LED Luminaire...
  • Page 2 E.g. basic insulation, reinforced insulation. 5. Terminal block not included. Installation may require advice from a qualified person. Document Number: 300S Softlight Luminaires Users Version as of: 24-004-3801-01 Rev1.1 300S Softlight Luminaire Installation & User’s Manual ©2016 Philips Group. All rights reserved.
  • Page 3: Warnings And Notices

    Philips Strand Lighting offers a two year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery A copy of Philips Strand Lighting two year limited warranty containing specific terms and conditions can be obtained from the Philips Strand Lighting web site at www.strandlighting.com...
  • Page 4: Table Of Contents

    LCD Display and Menu System Operation ......................Menu Structure ..............................Button Functions ..............................Dimming Curve Selection....................... DMX Control Simplify 8-bit ............................. Basic 8-bit ............................Basic 16-bit ............................. 300S Softl ght LED Luminaire RDM Parameter IDs ..................300S 5600k LED Luminaire RDM Parameter IDs ..
  • Page 5: Preface

    Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be downloaded at www.strandlighting.com. Product Descriptions This manual covers the following 300S SOFTLIGHT LED Luminaire models: 300S SOFTLIGHT 3100K with MO Yoke 300S SOFTLIGHT 5600K with MO Yoke...
  • Page 6: 300S Softlight Led Luminaire Overview

    Value turn / Push to confirm Yoke Color LCD Display/ Operation keypad Power Input (AC) DMX-512A(RDM) THRU Power THRU (AC) Power Input (DC) DMX-512A(RDM) IN Front of Unit High Power LED array Figure 1: 300S Softlight LED Luminaire Components 300S Softlight LED LUMINAIRE OVERVIEW...
  • Page 7: 300S Softlight Led Luminaire Lcd Display/Menu System

    300S Softlight LED Luminaires LCD Display/Menu System LED/Tungsten Menu Address Address settings UP Arrow Button DMX Address 5000 cd 90 CRI PL-Curve LCD Display Intensity 5600 DOWN Arrow Button Curves Figure 2: 300S Softlight LED Luminaire LCD Display/Menu System LCD Display/Menu System...
  • Page 8: Installation And Set Up Power Requirements

    INSTALLATION AND SET UP Power Requirements The 300S Softlight LED Luminaire operates on AC input voltages from 100 to 240VAC or 23 to 36 VDC. WARNING! This unit does not contain an ON OFF switch Always disconnect power input cable to completely remove power from unit when not in use.
  • Page 9: Connecting 300S Softlight Led Luminaires To Ac Power

    Input connector is a user supplied accessory to fit your application. Table2 describes how to connect power to your 300S Softlight LED Luminaire Field wiring of the 300S Softlight LED Luminaire is straight forward A total of 3 wires conductors is supplied from the unit...
  • Page 10: Connecting To The Dmx512 Network

    300S Softlight LED Luminaire. Rear of Unit DMX512(RDM) In DMX512( RDM) THRU Figure 4 300S Softlight LED Luminaire DMX512 Input Output Connections " " Note: For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on "...
  • Page 11: Mounting Luminaires

    Mounting Luminaire The 300S Softlight is provided with one mount and two safety cable anchor points, with one on the body and the other on the barn door assembly. The luminaire is designed to accept a variety of mounting hooks, clamps, etc.
  • Page 12: Operation And Program

    300S Softlight LED Luminaires Installation & User’s Manual OPERATION AND PROGRAMMING 1. LCD Display and Menu System The 300S Softlight LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings: Auto Lock Intensity Format...
  • Page 13: Menu Structure

    Last Hold Last Hold 6. Set factory default 6. Set factory default Yes/No Yes/No Rev x.xx Rev x.xx 7. Firmware Version 7. Firmware Version 8. RDM UID xxxxxxxxx 8. RDM UID xxxxxxxxx Figure8: 300S Softlight LED Luminaire Menu Structure Menu Tree...
  • Page 14: Button Functions

    300S Softlight LED Luminaires Installation & User’s Manual 4 Button Functions When in Manual Mode the 300S Softlight LED Luminaire’s features can be accessed via the on board LCD menu system or via the select buttons: Address LED/Tungsten Curves G+/-M(NULL)
  • Page 15: Dimming Curve Selection

    PL_Curve S Curve Square Curve Linear Curve PL Curve DMX Value DMX Value *PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries. S Curve Square Curve DMX Value DMX Value Figure 9 300S Softlight LED Luminaire Dimmer Curves...
  • Page 16: Dmx Control

    0-100% Basic 8 bit Table 4 provides DMX channel mapping of all DMX512 control values when the 300S Softlight LED Luminaire is in Basic 8-bit mode (as set by the luminaire’s menu system). Table 4 300S Softlight LED Luminaire DMX Channel Mapping Basic 8 Bit Mode...
  • Page 17: 300S 5600K Led Luminaire Rdm Parameter Ids

    Installation & User’s Manual 300S Softlight LED Luminaires 300S Softlight 5600K LED Luminaire RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with 300S Softlight 5600K LED Luminaires. " " Table 6 300S Softlight 5600K LED Luminaire RDM Product Parameters IDs , "...
  • Page 18 0x00A0 LANGUAGE_CAPABILITIES 0x00B0 LANGUAGE 0x00C0 SOFTWARE_VERSION_LABEL 0x00C1 BOOT_SOFTWARE_VERSION_ID 0x00C2 BOOT_SOFTWARE_VERSION_LABEL Category DMX512 Setup DMX_PERSONALITY 0x00E0 DMX_PERSONALITY_DESCRIPTION 0x00E1 DMX_START_ADDRESS * Required if device uses a DMX Slot 0x00F0 SLOT_INFO 0x0120 SLOT_DESCRIPTION 0x0121 DEFAULT_SLOT_VALUE 0x0122 300S Softlight 5600K LED Luminaire Parameters IDs...
  • Page 19 Installation & User’s Manual 300S Softlight LED Luminaires Table 8 300S Softlight 5600K LED Luminaire RDM Parameters Ids RDM Parameter IDs Value Comment Implemented Allowed Allowed Category Sensors 0x02xx SENSOR_DEFINITION 0x0200 SENSOR)VALUE 0x0201 RECORD_SENSORS 0x0202 Category Dimmer Settings 0x03xx Future...
  • Page 20 300S Softlight LED Luminaires Installation & User’s Manual Table 9 300S Softlight 5600K LED Luminaire RDM Manufacturer Specific PIDs for Root Device Type Length Unit Prefix Default Description Allowed Allowed Parameter IDs Category Manufacturer Defined PIDs Range is 0x8000 0xffdf See ANSI E1.20 2010 Standard Table A 3 ■...
  • Page 21: 300S 3100K Led Luminaire Rdm Parameter Ids 19

    Installation & User’s Manual 300S Softlight LED Luminaires 300S Softlight 3100K LED Luminaire RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with 300S Softlight 3100K LED Luminaires. " " Table 10 300S Softlight 3100K LED Luminaire RDM Product Parameters IDs , "...
  • Page 22 0x00A0 LANGUAGE_CAPABILITIES 0x00B0 LANGUAGE 0x00C0 SOFTWARE_VERSION_LABEL 0x00C1 BOOT_SOFTWARE_VERSION_ID 0x00C2 BOOT_SOFTWARE_VERSION_LABEL Category DMX512 Setup DMX_PERSONALITY 0x00E0 DMX_PERSONALITY_DESCRIPTION 0x00E1 DMX_START_ADDRESS * Required if device uses a DMX Slot 0x00F0 SLOT_INFO 0x0120 SLOT_DESCRIPTION 0x0121 DEFAULT_SLOT_VALUE 0x0122 300S Softlight 3100K LED Luminaire Parameters IDs...
  • Page 23 Installation & User’s Manual 300S Softlight LED Luminaires Table 12 300S Softlight 3100K LED Luminaire RDM Parameters Ids RDM Parameter IDs Value Comment Implemented Allowed Allowed Category Sensors 0x02xx SENSOR_DEFINITION 0x0200 SENSOR)VALUE 0x0201 RECORD_SENSORS 0x0202 Category Dimmer Settings 0x03xx Future...
  • Page 24 300S Softlight LED Luminaires Installation & User’s Manual Table 13 300S Softlight 3100K LED Luminaire RDM Manufacturer Specific PIDs for Root Device Type Length Unit Prefix Default Description Allowed Allowed Parameter IDs Category Manufacturer Defined PIDs Range is 0x8000 0xffdf See ANSI E1.20 2010 Standard Table A 3 ■...
  • Page 25: Maintenance And Care Special Cleaning Care Instruction

    Reagent grade isopropyl alcohol* A mild soap solution. Note: *Reagent grade isopropyl alcohol is good to use on the 300S Softlight LED Luminaire plastic optics with anti-reflection coatings. if the lens is still dirty after using isopropyl alcohol, for instance if fingerprints or oil is just redistributed and not cleaned off the optic, then a mild soap and water solution can be used to gently wash the lens.
  • Page 26: Accessories

    Installation & User’s Manual Accessories The 300S Softlight series will have 3 optional accessories including a barndoor with filter clip, a 20 degree honeycomb, and a 36 degree honeycomb. All these accessories can be equipped with the luminaire sololy or via a combination.
  • Page 27: Installation Of Accessories

    Installation & User’s Manual 300S Softlight LED Luminaires Installation of the accessories All accessories can be equipped to the 300S Softlight luminaire, whether individually or a combination. See the illustration below for more information. 300S Softlight with 36 degree honeycomb on...
  • Page 28: Features And Specifications 300S Softlight Technical Specification

    300S Softlight LED Luminaires Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. 300S Softlight LED Luminai re Operational Specifications Beam Angle: 50 Degrees Light Output: 24700 lumens for 3100K 27,484 lumens for 5600K Color Temperature: 3100K+/-100K 5600K+/-300K Input Voltage(AC): (+/- 100V to 240V...
  • Page 29: 300S Softlight Dimensions

    Installation & User’s Manual 300S Softlight LED Luminaires NOTE NOTE...
  • Page 30 Strand Selecon Auckland 19-21 Kawana Street Northcote, Auckland 0627 New Zealand Tel: +64 9 481 0100 Fax:+64 9 481 0101 Strand Lighting Europe Marssteden 152 Enschede 7547 TD The Netherlands Tel: +31 53 4500424 Fax:+31 53 4500425 www.strandlighting.com ©2016 Philips Group...