5.1.2 Setting Communication Conditions

• The communication in the two-way 2 mode is only available for 1:1 connection, and specify the unit
numbers within a range of 00 to 63.
• The settings for "Baud rate", "Data length" and "Parity check" should be the same as the
communication settings specified on the external device.
• In the two-way 2 mode, it is recommended to perform the CS/RS signal control to prepare for the case
that the response to a command from an external device and a message from the GT are sent at the
same time.
Item
Unit number
Baud rate
Data length
Stop bits
Parity check
CS/RS signal control
Note) CS/RS signal (control) is not available for GT01.
Reference:
For the details of the communication parameters of GT, refer to <2.1 Setting on GTWIN>.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Settings
00 to 63
115200/57600/38400/19200/9600 bps
7/8 bits
Fixed: 1 bit
Odd/Even/Invalid
No CS/RS signal (GT01)
Fixed: On (GT11, GT21)
On/Off (Other models)
Caution
Do not specify the same unit
number for multiple GTs.
These settings should be the same
as the settings specified on the
external device.
The CS/RS signals are not used in
the command response mode.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gt03-eGt05Gt12Gt32Gt32-eGt707 ... Show all