Fm-200 series integrated indicator type for gas flow sensor

Advertisement

Zero-point adjustment function
● The zero-point adjustment function is used to adjust the gap of the zero-point be-
tween the display and the analogue voltage output.
(Zero-point adjustment function)
Press
Adjusted value is indicated
9
PRO MODE
● In this mode, each detailed function can be set.
When pressing the MODE key after changing the set content of each item, the set
content is confirmed and returns to RUN mode.
Setting content of each item changes by pressing
(RUN mode)
(Flow direction settting)
Press
Hold down
for 8 sec.
(Flow rate unit settting)
Press
Press
(Eco mode settting) (Settings reset function) (Model display function)
Press
Flow direction setting
● S ets the flow direction of fluid. Either bi-direction, one-side forward direction or
one-side reverse direction can be set. (Factory setting: bi-direction)
● When setting flow direction to bi-direction or one-side forward direction, if fluid
flows in the direction opposite to the forward direction display on the main body,
the flow rate value is indicated negatively. In case of one-side reverse direction, if
the fluid flows in the same direction to the forward direction display, the flow rate
value is indicated negatively.
● Zero-point and the span of the analogue voltage output change as follows de-
pending on the set flow direction.
<Bi-direction (Factory setting)>
<One-side forward / one-side reverse direction>
5
Analogue
Analogue
3
voltage
voltage
output (V)
output (V)
1
-F.S.
0
+F.S.
Flow rate
(Flow direction setting)
(Bi-direction)
/
/
Press
Press
Note: If changing the flow direction setting, output mode (CH1 / CH2), threshold value (CH1 / CH2), zero-point adjust-
ment value, integrated flow rate value and CH2 setting are all cleared, then returns to the factory setting.
CH2 setting
● Select whether CH2 is used as comparative output 2, integrated value reset input
function or teaching function. (Factory setting: comparative output 2)
● When setting CH2 to the teaching function, select method for loading input value,
the number of input points and input waveform operation.
(CH2 seting)
(Integrated value reset input function) (Teaching function) (Note 3)
(Comparative output 2)
/
Press
/
(Note 1)
Press
To "CH2 setting mode" in
"MENU SETTING MODE"
(Note 2)
<Selection of 1-point input waveform operation>
ON when lower than
ON when higher than
threshold value
threshold value
/
Press
Press
(RUN mode)
Press
Notes: 1) When setting CH2, the threshold value of the comparative output 1 may be reset.
Therefore, confirm the threshold value of the comparative output 1 after setting CH2.
2) For CH2 setting mode, refer to "Output mode" in "
3) For teaching function, refer to "
TEACHING FUNCTION."
10
(RUN mode)
Press
(CH2 settting)
(Response time settting)
(Display speed settting)
Press
Press
(Hysteresis settting)
(Display color settting)
(Sub display settting)
Press
Press
Press
Press
(RUN mode)
5
1
0
+F.S.
Flow rate
F.S. = Full scale value
One-side forward
One-side reverse
direction
direction
/
Press
Press
Press
/
Press
Press
Press
(RUN mode)
<Selection of method for loading input value>
(Key operation)
/
Press
Press
<Selection of the number of input points>
(1-point input)
When pressing
/
Press
after selecting
When pressing
1-point input
selecting 2-point input
<Selection of 2-point input waveform operation>
ON when higher than threshold
ON when lower than threshold
value between 2 points
value between 2 points
/
Press
/
Press
ON when out of the 2 points
ON when within the 2 points
/
Press
MENU SETTING MODE."
8
Response time setting
● Sets response time. The response time can be selected from seven levels: 50 to
1,500ms. Chattering and malfunction due to rapid change in the flow rate can be
prevented. (Factory setting: 50ms)
Response
time setting
/
Press
Display
Response time
Note: The response time is applied to the sensor itself. Take care that the response time changes depending on piping.
Display speed setting
● Updating cycle of the digital display can be selected from three levels: 250ms,
500ms or 1,000ms. (Factory setting: 250ms)
Display speed
Press
setting
Press
Sub display setting
● F low direction, flow rate unit and applicable fluid can be indicated on the sub dis-
play. (Factory setting: flow direction)
(Sub display setting)
Press
Display color setting
● Display color of the digital display can be set either: red when comparative output
is ON, green when comparative output is ON, always red, or always green. (Fac-
tory setting: red when comparative output is ON)
● When setting either red when ON or green when ON, the color of the main display
changes in conjunction with the comparative output 1, while the color of the sub
display changes in conjunction with the comparative output 2.
(Display color setting)
/
Press
Hysteresis setting
● Sets hysteresis of the window comparator mode. The hysteresis can be selected
from eight levels: approx. 1 to 8% F.S. (Factory setting: approx. 1% F.S.)
(RUN mode)
Hysteresis
setting
/
Press
Flow rate unit setting
● Display unit can be set either ANR or NOR. (Factory setting: ANR)
ANR: Flow rate that is converted to +20°C, 1 atmosphere (101kPa) volume
NOR: Flow rate that is converted to 0°C, 1 atmosphere (101kPa) volume
(Flow rate unit setting)
/
ECO mode setting
● If not operating the key for approx. 1 min. after setting ECO mode, the digital dis-
play turns OFF (only "L" is displayed) and the current consumption can be re-
duced. (Factory setting: OFF)
(External input)
● Press any key to temporarily show the normal indication.
(ECO mode setting)
/
(2-point input)
Settings reset function
● Returns to the factory settings. (Factory setting: OFF)
after
(Settings reset function) (OFF)
/
Model display function
● D isplays the model. Zero-point adjustment value, full-scale (F.S.) flow rate, appli-
cable fluid, comparative output, flow rate unit and flow direction can be checked.
/
Press
(Model display function)
Full-scale (F.S.) flow rate
Zero-point
Press
adjustment
value
(Applicable fluid:
(50ms)
(80ms)
/
/
Press
Press
50ms
80ms
120ms
200ms
(250ms)
(500ms)
/
/
Press
(Flow direction)
(Flow rate unit)
/
/
Press
(Red when ON) (Green when ON) (Always Red)
/
/
Press
Press
(Approx. 1% F.S.)
(Approx. 2% F.S.)
/
/
Press
Press
(ANR)
(NOR)
Press
/
Press
(OFF)
(ON)
Press
/
Press
(ON)
Press
/
Press
Comparative output
Flow rate unit
/
/
Applicable fluid
Flow direction
Press
: Air, nitrogen)
(Comparative output: :NPN,
:PNP)
(1,500ms)
(RUN mode)
/
Press
Press
400ms
800ms
1,500ms
(1,000ms)
(RUN mode)
/
Press
Press
(Applicable fluid)
(RUN mode)
/
Press
Press
(Always Green)
(RUN mode)
/
Press
Press
(Approx. 8% F.S.)
(RUN mode)
/
Press
Press
(RUN mode)
Press
(RUN mode)
Press
(RUN mode)
Press
(RUN mode)
Press