User
Programing
Menu Items

User Programing Menu Items

ALARM VOLUME (2nd Tier)

(Default = 6, Parameters = 0 to 6, UL installations = 6)
This setting allows you to adjust the panel's siren volume. The volume can be set from 0 to 6,
with 0 being the lowest volume.
¾
To set the Alarm Volume:
Š Press #, enter the desired volume level and then press #.

Clear Memory (1st Tier)

It is strongly recommended that you clear memory on all newly installed panels before program-
ming.
Clear memory deletes all existing programming information and then resets the panel settings to
their default settings. The dealer code is not erased when panel memory is cleared.
¾
To clear panel memory:
1. Press 8, and enter the dealer or installer code. The display shows
2. Press
twice. The display shows
3. Press #.
4. Enter the dealer or installer code to clear memory.

EXIT DL (1st Tier)

If Exit is selected, the panel returns to active mode. If the installer/dealer or primary code is
entered, a downloader session will begin.
After all installer programming is completed, use the following procedure to exit programming
mode.
¾
To exit programming mode:
Press * until
-
is displayed
EXIT
DL
¾
To begin a downloader session:
Press * until
-
is displayed
EXIT
DL
Downloader session.
This section guides you through the user programing menu items.
There are two tiers of user programming menus. Tier 1 menus are accessible immediately after
entering the program mode.
Pressing
advances forward through the menus. Pressing
See "Panel Keypad Button Programming Functions" on page 5 for more information on navigat-
ing through programming menus.

Entering User Programming Mode

You can enter user programming mode using the primary access code. The default primary
access code is 1234.
¾
To enter user programming mode:
Š With the system disarmed, press 8 + code. This will take you to
Tier 1.
-
;
.
EXIT
DL
CLEAR MEMORY
and then press #. The current time will be displayed.
and then enter installer, dealer or primary code to start a
moves through the menus in reverse
(SIRENS—)
.
ACCOUNT
, the first menu item in
CODES
.
21