For ease in installation, it is best to make any necessary coil
configuration changes before setting the air handler in place. See
"Installation Configuration Options."
Upflow air discharge contains only 1 drain pan.
Upflow or horizontal airflow contains 2 drain pans.
Vertical Installations
Upflow
The air handler must be supported on the bottom only and set on
a field-supplied supporting frame with an air return opening.
Securely attach the air handler to the supporting frame.
Horizontal Installations
Horizontal installations can be left-hand or right-hand air supply.
Adequate support must be provided to ensure cabinet integrity.
Ensure that there is adequate room to remove, service and
access panels if installing in the horizontal position. For the
correct horizontal coil installation, see "Installation Configuration
Options" later in this section.
IMPORTANT:
This coil is provided with a secondary drain that should be
trapped and piped to a location that will give the occupant a
visual warning that the primary drain is clogged. See "Install
Condensate Drain."
When an evaporator coil is installed in an attic or above a
finished ceiling, an auxiliary drain pan should be provided
under the air handler as specified by most local building
codes.
Suspended Cabinet Installation
NOTE: Air handlers cannot be installed horizontally lying on or
suspended from either the front or back of the air handler. It must
be positioned with one side parallel to the floor when in the
horizontal position.
The suspending means must be field fabricated, and should
consist of 2 "cradles" made by attaching 2 rods to a length of
angle iron or suitable gauge steel.
Installation Configuration Options—Upflow
NOTES:
As shipped from the factory.
Return in bottom.
Shading indicates proper line connections.

Installation Configurations

A. Horizontal drain connections
(left or right hand)
Installation Configuration Options—Horizontal Right
NOTES:
Left to right airflow
As shipped from the factory
Installation Configuration Options—Horizontal Left
Right to left airflow
Requires drain pan location change
A
B
B. Upflow drain connection
C. Bottom/filter frame
Drains
A
B
A. Drain connections
B. Coil access cover
C. Blower access cover
.
Drains
A
B
A. Blower access cover
B. Coil access cover
C. Drain connections
A
C
C
C