Download Print this page

Mitsubishi Electric MELSEC iQ-F FX5-CCLIEF Hardware Manual

Programmable controller; melsec iq-f series

Advertisement

Quick Links

JY997D63901B
Side
JAPANESE
A
Side
ENGLISH
B
MELSEC iQ-F FX5-CCLIEF
Hardware Manual
Manual Number
JY997D63901
Revision
B
Date
July 2017
This manual describes the part names, dimensions, installation, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration: Ethernet is a trademark of Xerox Corporation. Phillips is a registered
trademark of Phillips Screw Company.
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.
Effective July 2017
Specifications are subject to change without notice.
2016 MITSUBISHI ELECTRIC CORPORATION
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in minor or moderate injury or
property damage.
Depending on the circumstances, procedures indicated by
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manual
Manual name
Manual No.
Description
MELSEC iQ-F FX5
Describes the functions of the
User's Manual
JY997D64201
CC-Link IE Field network module.
(CC-Link IE)
MELSEC iQ-F FX5U
E x p l a i n s F X 5 U C P U m o d u l e
User's Manual
JY997D55301
specification details for I/O, wiring,
(Hardware)
installation, and maintenance.
MELSEC iQ-F FX5UC
Explains FX5UC CPU module
User's Manual
JY997D61401
specification details for I/O, wiring,
(Hardware)
installation, and maintenance.
MELSEC iQ-F FX5
Programming Manual
D e s c r i b e s s p e c i f i c a t i o n s o f
(Instructions, Standard
JY997D55801
instructions and functions that can
Fu n c ti o n s / Fu n c ti o n
be used in programs.
Blocks)
How to obtain manuals
For the necessary product manuals or documents, consult with your local
Mitsubishi Electric representative.
Side
B
Applicable standards
FX5-CCLIEF comply with the EC Directive (EMC Directive) and UL standards (UL,
cUL). Further information can be found in the following manual.
MELSEC iQ-F FX5 User's Manual (CC-Link IE)
Regarding the standards that relate to the CPU module, please refer to either the
product catalog or consult with your local Mitsubishi Electric representative.
Attention
This product is designed for use in industrial applications.
1. Outline
FX5-CCLIEF intelligent device station for CC-Link IE Field network (hereinafter
referred to as FX5-CCLIEF) is an intelligent function module for connecting to a CC-
Link IE Field network as an intelligent device station.
1.1 Incorporated Items
Check that the following product and items are included in the package:
Product
FX5-CCLIEF intelligent device station for CC-Link IE Field network
FX2NC-100MPCB power cable: (1 m, three wire)
Included Items
Dust proof protection sheet (1 sheet)
Hardware manual (This manual)
1.2 External Dimensions, Part Names
[4] [5]
2-4.5 Mounting holes
[3]
[6]
[7]
[2]
[1]
16
50
20
[11]
[12]
MASS (Weight): Approx. 0.3 kg
Outer painting color: Munsell 0.6B7.6/0.2
may also
[1] Modular jack for P2 (RJ-45) (with cap)
[2] Modular jack for P1 (RJ-45) (with cap)
[3] Extension cable
[4] Dot matrix LED
[5] Direct mounting hole: 2 holes of
4.5 (mounting screw: M4 screw)
[6] Operation status display LEDs
[7] Extension connector (for next module)
[8] Name plate
[9] DIN rail mounting groove (DIN rail: DIN 46277, 35 mm wide)
[10] DIN rail mounting hook
[11] Pullout tab
[12] Power connector
1.3 Indications of LEDs
LED display
LED color
Status
On
*1
D LINK
Green
Flashing
Off
On
SD
Green
Off
On
RD
Green
Off
On
L ERR
Red
Off
On
POWER
Green
Off
On
RUN
Green
Off
[8]
Unit: mm
On
*1
ERROR
Red
Flashing
Off
[9]
On
L ER
Red
Off
P1
On
LINK
Green
Off
On
[10]
8
L ER
Red
Off
83
P2
On
LINK
Green
Off
Dot matrix LED
Orange
-
*1 The LED is always off in offline mode.
2. Installation
Indication
INSTALLATION
PRECAUTIONS
D a ta li n k ( cy c li c tr an sm i ss i on be i ng
 Make sure to cut off all phases of the power supply externally before
performed)
attempting installation or wiring work.
Data link (cyclic transmission stopped)
Failure to do so may cause electric shock or damage to the product.
 Use the product within the generic environment specifications described in
Data link not performed (disconnection)
the User's Manual (Hardware) for the CPU module to be used.
Data being sent
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl
Data not being sent
vibration or impacts, or expose it to high temperature, condensation, or rain
Data being received
and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
Data not being received
deterioration or damage may occur.
Error data are received
INSTALLATION
Normal data are received
PRECAUTIONS
Power on
 Do not touch the conductive parts of the product directly.
Power off
Doing so may cause device failures or malfunctions.
 When drilling screw holes or wiring, make sure that cutting and wiring debris
Normal operation
do not enter the ventilation slits of the PLC.
Error
Failure to do so may cause fire, equipment failures or malfunctions.
 The dust proof sheet should be affixed to the ventilation slits before
Minor error
installation and wiring work to block foreign objects such as cutting and wiring
(Major error when the RUN LED turns off)
debris. However, when the installation work is completed, make sure to
remove the sheet to provide adequate ventilation.
Moderate error
Failure to do so may cause fire, equipment failures or malfunctions.
(Major error when the RUN LED turns off)
 Install the product on a flat surface.
Normal operation
If the mounting surface is rough, undue force will be applied to the PC board,
Error data are received
thereby causing nonconformities.
 Install the product securely using a DIN rail or mounting screws.
Normal data are received
 Connect the extension cables securely to their designated connectors.
Link-up
Loose connections may cause malfunctions.
Link-down
For further information on mounting, refer to the following manual.
Error data are received
Normal data are received
3. Wiring
Link-up
Link-down
WIRING PRECAUTIONS
Displays the station number set in the
 Make sure to cut off all phases of the power supply externally before
module and the module communication
attempting installation or wiring work.
test result.
Failure to do so may cause electric shock or damage to the product.
WIRING PRECAUTIONS
 Securely connect the connector to the module. Poor contact may cause
malfunction.
 Make sure to observe the following precautions in order to prevent any
damage to the machinery or accidents due to malfunction of the PLC caused
by abnormal data written to the PLC due to the effects of noise:
- Do not bundle the power line and communication cables together with or
lay them close to the main circuit, high-voltage line, load line or power line.
As a guideline, lay the power line, control line and communication cables
at least 100 mm away from the main circuit, high-voltage line, load line or
power line.
, H
S, SO
or NO
), flammable gas,
2
2
2
2
MELSEC iQ-F FX5U User's Manual (Hardware)
MELSEC iQ-F FX5UC User's Manual (Hardware)

Advertisement

loading

Summary of Contents for Mitsubishi Electric MELSEC iQ-F FX5-CCLIEF

  • Page 1 Regarding the standards that relate to the CPU module, please refer to either the  Make sure to cut off all phases of the power supply externally before performed) MELSEC iQ-F FX5-CCLIEF product catalog or consult with your local Mitsubishi Electric representative. attempting installation or wiring work. D LINK Green...
  • Page 2 This manual confers no industrial property rights or any rights of any other kind, PRECAUTIONS 1024 points, 2048 bytes nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be  Please contact a certified electronic waste disposal company for the held responsible for any problems involving industrial property rights which may environmentally safe recycling and disposal of your device.