JY997D28601B(ENGLISH)
-
FX
(D,DSS) SERIES
3UC
PROGRAMMABLE CONTROLLERS
HARDWARE MANUAL
Manual Number
JY997D28601
Revision
B
Date
November 2007
This manual describes the part names, dimensions, mounting,
cabling and specifications for the product. This manual is extracted
from FX
Series User's Manual - Hardware Edition. Refer to
3UC
FX
Series User's Manual - Hardware Edition details. Before use,
3UC
read this manual and manuals of relevant products fully to acquire
proficiency in the handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that it can be taken out and
read whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this
manual are the registered trademarks or trademarks of each
company.
Effective November 2007
Specifications are subject to change without notice.
© 2007 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Depending on the circumstances, procedures indicated by
may also cause severe injury.
It is important to follow all precautions for personal safety.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals, cut off all phases of
the power supply externally.
Failure to do so may cause electric shock.
• Make sure to connect the battery for memory backup correctly.
Do not charge, disassemble, heat, short-circuit, or expose the
battery to fire.
Doing so may rupture or ignite it.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Before modifying or disrupting the program in operation or
running the PLC, carefully read through this manual and the
associated manuals and ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND
MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the
memory cassette. If the memory cassette is attached or
detached while the PLC's power is on, the data in the memory
may be destroyed, or the memory cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric distributor.
• Turn off the power to the PLC before connecting or disconnecting
any extension cable.
Failure to do so may cause equipment failures or malfunctions.
• Turn off the power to the PLC before attaching or detaching the
following devices.
Failure to do so may cause equipment failures or malfunctions.
- Peripheral devices, extension blocks, connector conversion
adapter, extension power supply units, special adapters, and
FX Series terminal blocks.
- Battery and memory cassettes
DISPOSAL
PRECAUTIONS
• Please contact a certified electronic waste disposal company
for the environmentally safe recycling and disposal of your
device.
TRANSPORT AND
STORAGE
PRECAUTIONS
• Before transporting the PLC, turn on the power to the PLC to
check that the BAT LED is off.
If the PLC is transported with the BAT LED on or the battery
exhausted, the battery-backed data may be unstable during
transportation.
• The PLC is a precision instrument. During transportation, avoid
impacts larger than those specified in Section 2.1. Failure to do
so may cause failures in the PLC.
After transportation, verify the operations of the PLC.
Certification of UL, cUL standards
The FX
main units and input/output extension units/blocks
3UC
supporting UL, cUL standards are as follows:
UL, cUL file number :E95239
Models :
MELSEC FX
series manufactured
3U(C)
FX
-
MT/D
FX
-
MT/DSS
3UC
3UC
Where
indicates:16,32,64,96
FX
-232ADP(-MB)
FX
-485ADP(-MB)
3U
3U
FX
-4AD-ADP
FX
-4DA-ADP
3U
3U
FX
-4AD-PT-ADP
FX
-4AD-TC-ADP
3U
3U
FX
-1PS-5V
3UC
Models :
MELSEC FX
series manufactured
2NC
FX
-16EX(-DS)
FX
-32EX(-DS)
2NC
2NC
FX
-16EYT(-DSS) FX
-32EYT(-DSS)
2NC
2NC
FX
-16EX-T(-DS)
FX
-16EYR-T(-DS)
2NC
2NC
Models :
MELSEC FX
series manufactured
2N
FX
-8ER-ES/UL
FX
-8EX-ES/UL
2N
2N
FX
-8EYR-ES/UL
FX
-8EYT-ESS/UL
2N
2N
FX
-8EX-UA1/UL
2N
FX
-16EX-ES/UL
FX
-16EYR-ES/UL
2N
2N
FX
-16EYT-ESS/UL FX
-16EYS
2N
2N
Compliance with EC directive (CE Marking)
This document does not guarantee that a mechanical system
including this product will comply with the following standards.
Compliance to EMC directive and LVD directive of the entire
mechanical system should be checked by the user / manufacturer.
For more details please contact the local Mitsubishi Electric sales
site.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Electromagnetic Compatibility (89/336/EEC) when used
as directed by the appropriate documentation.
Type :
Programmable Controller (Open Type Equipment)
Models :
MELSEC FX
3U(C)
series and FX
2NC
series
manufactured
from May 1st, 2005
FX
-FLROM-16
FX
-FLROM-64L
3U
3U
from June 1st, 2005
FX
-232ADP
FX
-485ADP
3U
3U
FX
-4AD-ADP
FX
-4DA-ADP
3U
3U
FX
-4AD-PT-ADP FX
-4AD-TC-ADP
3U
3U
FX
-FLROM-64
3U
from April 1st, 2007
FX
-232ADP-MB
FX
-485ADP-MB
3U
3U
from September 1st, 2007 FX
-
MT/D
FX
-
3UC
3UC
Where
indicates:16,32,64,96
from October 1st, 2007
FX
-1PS-5V
3UC
FX
-
EX
FX
-
2NC
2NC
FX
-
EX-DS
FX
-
2NC
2NC
Where
indicates:16,32
FX
-16EX-T
FX
-16EX-T-DS
2NC
2NC
Standard
Remark
EN61131-2:2003
Compliance with all relevant aspects of
Programmable
the standard.
controllers
EMI
• Radiated Emissions
- Equipment
• Mains Terminal Voltage Emissions
requirements and
tests
EMS
• RF immunity
• Fast Transients
• ESD
• Surge
• Voltage drops and interruptions
• Conducted
• Power magnetic fields
Models : MELSEC FX
series manufactured
2NC
from March 1st, 1999
FX
-
EX-DS
FX
-
2NC
2NC
Where
indicates:16,32
from August 1st, 1999
FX
-16EX-T-DS FX
-16EYR-T-DS
2NC
2NC
from October 1st, 2007 FX
-
EX
FX
-
2NC
2NC
Where
indicates:16,32
FX
-16EX-T
FX
-16EYR-T
2NC
2NC
Standard
EN61000-6-4:2001
Compliance with all relevant aspects of
- Generic emission
the standard.
standard Industrial
• Radiated Emissions
environment
• Mains Terminal Voltage Emissions
EN50081-2:1993
Electromagnetic
compatibility
EN61000-6-2:2001
Compliance with all relevant aspects of
- Generic immunity
the standard.
standard Industrial
• RF immunity
environment
• Fast Transients
• ESD
• Conducted
• Surge
• Power magnetic fields
• Voltage drops and interruptions
Models : MELSEC FX
series manufactured
2N
from July 1st, 1997
FX
-16EX-ES/UL
2N
FX
-16EYT-ESS/UL
2N
from August 1st, 2005
FX
-8ER-ES/UL
2N
FX
-8EYR-ES/UL FX
2N
For the products above, PLC's manufactured
before March 31st, 2002 are compliant with EN50081-2 (EN61000-
6-4) and EN50082-2 only.
PLC's manufactured from April 1st, 2002 to April 30th, 2006 are
compliant
with
EN50081-2
(EN61000-6-4)
2:1994+A11:1996+A12:2000
PLC's manufactured after May 1st, 2006 are compliant with
EN61131-2:2003
MT/DSS
Standard
EN61000-6-4:2001
Compliance with all relevant aspects of
EYT
- Generic emission
the standard.
EYT-DSS
standard Industrial
• Radiated Emissions
environment
• Mains Terminal Voltage Emissions
EN50081-2:1993
Electromagnetic
compatibility
EN50082-2:1995
Compliance with all relevant aspects of
Electromagnetic
the standard.
compatibility
• RF immunity
• Fast Transients
- Generic immunity
• ESD
standard Industrial
• Conducted
environment
• Power magnetic fields
EN61131-2:1994
Compliance with all relevant aspects of
/A11:1996
the standard.
/A12:2000
• RF Immunity
• Fast Transients
Programmable
• ESD
controllers
• Damped oscillatory wave
- Equipment
requirements and
tests
EYT-DSS
EYT
Remark
FX
-16EYR-ES/UL
2N
FX
-8EX-ES/UL
2N
-8EYT-ESS/UL
2N
and
EN61131-
Remark