654A Test Oscillator - HP 654A Operating And Service Manual

Test oscillator
Hide thumbs Also See for 654A:
Table of Contents

Advertisement

Section 1
Model
654A
I
-
B lfloO S
}
r
Figure 1-1. Model 654 A Test Oscillator
Table I-I. Specifications
frequency range: 10 Hz to 10 MHz in 6 bands.
Frequency accuracy:
100 Hz (on
Xl
00 RANGE) to
5
MHz: +/-2%
10 Hz to 100 Hz:
+/-3%
5 MHz to 10 MHz: +/-4%
Level flatness(+IO dBm and 0 dBm): +/-0
.5%
referenced
to level at I kHz from 10Hz to 10 MHz for un-
balanced outputs, 10 Hz to 5 MHz for 135 ohm and
150 ohm outputs, and 10 Hz to I MHz for 600 ohm
output.
Attenuator
Range: 99 dB in 10 dB and I dB
steps.
Accuracy: +/-1.5% (0.15 dB) except
+/-10%
(I
dB) at
output levels below 60 dBm at frequencies greater
than 300 kHz
.
Amplitude control: greater than 2 dB.
Amplitude accuracy: +/-1
%
for 90 days (at
I kHz,
+ I 0 dBm level with meter centered).
Meter tracking: +/-0.05 dB.
Balance (on balanced impedances) when measured by the
procedure given in Paragraph 5-28
:
greater than 50 dB
for frequencies from 10Hz to I MHz, greater than
40 dB to 5 MHz
.
Distortion (THD)
10Hz to I MHz
:
greater
than 40 dB below fu nda-
mental
.
I MHz to 10 MHz: greater than 34 dB below funda-
mental.
Hum and noise: greater than 70 dB down at full
output.
Table 1-2. General Information
Output impedance: 50
ohm
unbalanced, 75 ohm un-
balanced, 135 ohm balanced, 150 ohm balanced and
600
ohm balanced.
Output level: +11 dBm to -90 dBm, 10 dB and I dB steps
with adjustable +/-1 dB meter range; calibrated for
each
impedance.
Meter resolution: 0.02 dB.
1·2
Output connectors: BNC
.
Maximum voltage
which
can be
applied to the output: less than +/-3 V peak.
Counter output: greater than 0 .1 V rms into 50 ohm
,
BNC connector.
Operating temperature: OOC to +55
0
C (32°F to 130°F).
Power: 115 V or
230
V +/ .
10%,
48 Hz to
66
Hz, 30 W
.1/
1
nominal, 35 W max.
~

Advertisement

Table of Contents
loading