74
These tests should be done when machine is first installed and after servicing when
any components are replaced.
1. Power on machine but do reference.
Start spindle. (Press Shift-Spindle on)
Spindle will not start OR
Press Emergency Stop; spindle must stop.
Immediately release Emergency Stop; spindle does not start.
2. Reference machine.
Start spindle.
Press Emergency Stop; spindle must stop.
Immediately release Emergency Stop; spindle shall not start, VMC remains in
emergency stop.
Repeat test in Auto, MDI, and Jog modes.
3. Start spindle. (Press Shift-Spindle on)
Open front door; spindle must stop.
Try to restart spindle; spindle does not start with doors open.
Check contactor for spindle; contacts should be out. (There may be a 5 to 10 sec-
ond delay between the opening of the door and the release of the contactor. This
allows a controlled stop).
4. Close doors.
Repeat test with left side panel.
Repeat test with right side panel.
MACHINE MAINTENANCE