Sony BRC-300 Service Manual page 77

3ccd color video camera / optical multiplex unit
Hide thumbs Also See for BRC-300:
Table of Contents

Advertisement

3. Date initialization of pages E, F, 1E, and 1F
m
. When reading or writing the data of page 1E or 1F,
select page: 0, address: 10, and set data: 01, then select
the page E or F. The page 1E or 1F can be chosen by this
data setting.
After reading or writing, reset the data of page: 0,
address: 10 to "00".
. If "Date initialization of pages E, F, 1E, and 1F" is
performed, all data of the pages E, F, 1E, and 1F will be
initialized. (It is impossible to initialize a single page.)
. After initializing the data of pages E, F, 1E, and 1F,
perform the all adjustments in Sections 3-2-8 and 3-2-21
again.
Adjusting page
Adjusting address
E
00 to FF
F
10 to FF
1E
00 to C3
1F
00 to FF
Initializing method
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
6
01
4
6
03
01
5
6
02
BRC-300/300P
BRU-300/300P
Set the data.
Set the data.
Set the following data, and
press PAUSE button.
2D (NTSC)
2F (PAL)
Set the data, and press
PAUSE button.
Check that the data changes to
"01".
3-2. BRC-300/300P Camera Block Electrical Alignment