5. Channel BUTTON:
- In the normal mode, press the button to switch the between channel 1, 2 and 3 to receive the 433.92MHz signal;
press and hold the button for 3 seconds will pairing with the outdoor remote sensor.
6. Reset BUTTON:
- In case of malfunction, press RESET button to reset all values to default values.
7. WALL MOUNT
8. M. SET (Manual Set) BUTTON:
- In normal mode, press and hold the M.SET button, second hand will stop and enter into manual setting. Keep
pressing the M.Set button, the minute hand will run quickly. Release the button to exist the manual setting and
the clock will start running within few seconds.
9. REC (Force Receiving) BUTTON:
- In normal mode, press and hold the REC button, the hands will stop running and enter into Force Receiving
mode. It will start receiving the Atomic time signal within 10 minutes. Once received the signal successfully,
the clock hands will found the correct time and run normally. Otherwise, it will return to the time before Force
Receiving.
10. DST ON/OFF SWITCH:
- Before insert the battery, select the DST mode. The clock has programmed to automatically switch when the
daylight saving time is in effect.
11. TIME ZONE SWITCH:
- Before insert the battery, select the correct time zone. The default time zone is P (Pacific Time). If your location
is not in the Pacific, slide the time zone switch to M (Mountain Time) / C (Central Time) / E (Eastern Time) zone.
12. REC BUTTON:
- Function same as No. 9
13. M. SET BUTTON:
- Function same as No. 8
14. BATTERY COMPARTMENT AND DOOR:
- Use 1 x AA size battery
Remote Transmitter
1. LED INDICATOR:
- LED Flashes when the remote unit transmits a reading
2. CHANNEL SLIDE SWITCH (inside battery compartment):
- Assign the transmitter to channel 1, 2 or 3 to receive 433.92MHz signal
3. RESET BUTTON:
- Press it to restart the transmitter and return all values to default values.
4. BATTERY COMPARTMENT:
- Use 2 AA Size batteries.
5. BATTERY DOOR
6. WALL MOUNT
7. TABLE STAND
SETTING UP THE TRANSMITTER:
1. Remove the battery door and insert 2 AA batteries into the battery compartment and follow the polarities marked.
2. Slide the switch to Channel 1. Press the RESET button to set the transmitter.
3. Press the CHANNEL button at the back of the clock to set channel 1.
4. Lock the transmitter battery door with the screw.
5. Place the units away from metal objects and electrical appliances to minimize interference. Position the receiver
within the effective transmission range 30 meters in usual circumstances.
6. If Channel 1 signal is not received properly, change the transmitter slide button to Channel 2 or 3. Press CHANNEL
button of the clock to 2 or 3 respectively. Press and hold the CHANNEL button for three seconds. The unit will start
to find the new channel.
NOTE:
1. To receive the transmitter signal, the channels of receiver and transmitter must match each other.
2. Once the channel is assigned to transmitter, you can only change it by removing the batteries or resetting the unit.
SUGGESTION:
Make sure you read the instructions before operating this clock. We have developed this sophisticated instrument for
the best reception performance; however, the signal transmitted from USA Atomic Clock transmitter will be affected in
certain situations. We advise you to note the following instructions:
1. It is strongly recommended to start this clock at night and let the clock receive the signal automatically past midnight.
2. Always place the unit away from interfering sources such as TV set, computer, etc.
3. Avoid placing the unit on or next to metal plates.
4. Areas with access to windows is recommended for better reception.
5. Do not start reception in moving articles such as vehicles or trains.
BATTERY REPLACEMENT:
If the low battery indicator appears beside the outdoor temperature of main unit, it indicates that the transmitter
batteries need replacement. If the low battery indicator is displayed at the top left corner, it indicates that the atomic
clock batteries need replacement.
NOTE:
Attention! Please dispose of used unit or batteries in an ecologically safe manner.
BATTERY WARNING:
- Clean the battery contacts and also those of the device prior to battery installation. Follow the polarity (+) and (-)
to place battery.
- Do not mix old and new batteries.
- Do not mix Alkaline, Standard (Carbon - Zinc), or Rechargeable (Nickel - Cadmium) batteries.
- Incorrect battery placement will damage the clock movement and battery may leak.
- Exhausted battery is to be removed from the product.
- Remove batteries from equipment which is not to be used for an extended period of time.
- Do not dispose of batteries in fire. Batteries may explode or leak.
USING THE WALL MOUNT:
The transmitter has the desktop and wall mounting structure.
- For the Atomic Clock, use the recessed hold on the back of the clock to hang it.
- For the Transmitter, hang or place the separate wall-mounting part in an area protected from direct rain. Once the
stand is mounted, place the transmitter into the stand on the wall.
SPECIFICATIONS:
MAIN UNIT
Recommended operating range: 0℃ to 45℃, 32℉ to 113℉
Resolution:
0.1℃/℉(above 0℃/32℉), 1℃/℉(below 0℃/32℉)
Humidity measuring range:
20% RH to 95%RH
Recommended operating range: 20% RH to 95%RH
Resolution:
1%RH