Connecting the Interface Cable
USB Interface Cable Connection
1.
Make sure both the printer and the host computer are turned off.
2.
Hook the USB cables through the locking wire strain relief to keep it in
place.
USB upstream
connector
USB
downstream
connector
(USB HUB:
UB-U01III only)
3.
Insert the square connector end of the USB cable into the upstream
connector of the UB-Board.
4.
Insert the opposite end of the USB cable into the downstream connector of
the host computer.
5.
Change the printer settings to the parallel interface settings. If you use a
printer that permits selecting the setting of the I/F pin 31 reset signal,
select "Enabled." For details, see the settings described in the printer
documentation.
6.
Install the device driver for the TM-U01III/U02III/U03II. For installation
procedures, please ask your dealer.

Display Module

If you install a display module, be sure to use the following settings.
Item
Transmission setting
Default setting of Device selection
(only for displays for which the
setting can be changed)
Connection type
(only for displays for which the
setting can be changed)
Selection
Baud rate
Parity
Data word length
Only display selected
Y connection disabled
3
English
DM connector
locking wire
strain relief
USB cable
19200 bps
None
8 bit