DeWalt DCW100 Instruction Manual page 11

Portable stick and tig welder
Hide thumbs Also See for DCW100:
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Description
Break voltage (Uco)
Used to specify at which arc length
the welding process is completed.
The welding voltage increases as
the length of the arc increases. The
arc is extinguished when it reaches
the voltage specified here.
Factory setting: 45 volts
Software version (SOF)
The full version number of the
currently installed software is
contained in a number of displays
and can be retrieved by turning the
adjusting dial.
Automatic switch-off (tSd)
If the device is not used or operated
for a specified period of time, it
switches off automatically. Factory
setting: 900 seconds.
Factory setting (FAC)
This can be used to reset the
device to its factory settings.
- Cancel reset
- Reset the parameters for the
selected welding process to
their factory settings
- Reset the parameters for all
welding processes to their
factory settings
Resetting of the selected value to its
factory setting must be confirmed
by pressing the adjusting dial.
Range
Unit
Parameter
25 - 80
Volt
300- 900 Seconds
no
YES
ALL
11
Parameters for TIG Welding
Description
Range
Comfort Stop Sensitivity (CSS)
0.3 - 2.0
This parameter is only available
when the tri parameter is set to OFF.
Factory setting: 2.0
Break voltage (Uco)
12 - 35
Used to specify at which arc length
the welding process is completed.
The welding voltage increases as
the length of the arc increases.
The arc is extinguished when it
reaches the voltage specified here.
Factory setting: 15 volts
Software version (SOF)
The full version number of the
currently installed software is
contained in a number of displays
and can be retrieved by turning
the adjusting dial.
Automatic switch-off (tSd)
300- 900 Seconds
If the device is not used or
operated for a specified period of
time, it switches off automatically.
Factory setting: 900 seconds.
Unit
Volt
Volt

Hide quick links:

Advertisement

Table of Contents
loading