Toro Network 8000 Installation Instructions
Toro Network 8000 Installation Instructions

Toro Network 8000 Installation Instructions

Satellite communication surge protection kit
Hide thumbs Also See for Network 8000:

Advertisement

Quick Links

Introduction
Due to the unpredictable magnitude of high voltage transients caused by lightning, surge protection devices in general can-
not control all power surge conditions. However, when properly installed and grounded, the surge protection module includ-
ed in this kit will provide the maximum surge protection possible for the Network 8000 communication modem.
Installing the surge protection kit is relatively easy due to its modular design and plug-in wiring harness. To determine the
tools and additional materials required to complete the installation, please read through the instructions completely prior
to starting the installation procedure.
WARNING:
INJURY AND/OR EQUIPMENT DAMAGE.
AVERTISSEMENT:
SERIEUX DOMMAGES CORPORELS ET / OU MATERIALS.
WARNUNG:
ERNSTHAFTEN VERLETZUNGEN UND / ODER SCHÄDEN AN DEN GERÄTEN KOMMEN.
Installation Procedure
Note 1: Due to the variations in controller rear plate
configuration, specific location for the surge protec-
tion module is not given. Suggested areas for instal-
lation (represented by dashed lines) are shown in
Figure 1. If no space is available on the rear plate,
attach module support bracket to cabinet side wall
using Velcro strips (not supplied). Without rear plate
contact, ground lug/ wire connection is essential
for proper operation of surge protection compo-
nents.
1. Unlock and remove pedestal cabinet door(s).
2. Using surge protection module support bracket
(91-1427) as a template, mark location of two
mounting screw holes on controller rear plate
assembly. See Figure 1.
3. Center punch and drill two screw holes in rear
plate using a #32 (3mm) drill bit.
4. Secure support bracket to rear plate assembly
with two self tapping screws provided.
6. Secure surge protection module to support brack-
et using four machine screws provided.
7. Loosen nut securing ground lug on surge protec-
tion PCB. Rotate ground lug clockwise 90° and
retighten. See Figure 2.
8. Route communication cable wires to surge pro-
tection module and connect to terminals 1 – 4 as
shown in Figure 2.
Note 2: Comm cable wires are shown separated for
illustration clarity. In actual installation, comm wire
pairs should remain twisted.
9. Connect surge protection module to satellite
modem PCB using shielded cable assembly pro-
vided as shown in Figure 2. Plug is correctly ori-
ented in surge protection PCB receptacle as
follows: Black wire to "Gray", White wire to
"Yellow" and Drain wire to "Gnd".
I I
n n
s s
t t
a a
l l
l l
a a
t t
i i
o o
n n
I I
n n
I I
n n
s s
t t
a a
l l
l l
a a
t t
i i
o o
n n
I I
n n
Network 8000 Satellite
Communication Surge Protection Kit 91-1453
DISCONNECT POWER TO CONTROLLER AT SOURCE. FAILURE TO COMPLY MAY RESULT IN SERIOUS
DEBANCHER LE SECTEUR ARRIVANT AU PROGRAMMATEUR. SI L' ON NE SE CONFORME
TRENNEN SIE DIE STROMVERSORGUNG ZUM STEUERGERÄT AB. ANDERNFALLS KANN ES ZU
s s
t t
r r
u u
c c
t t
i i
o o
n n
s s
s s
t t
r r
u u
c c
t t
i i
o o
n n
s s
Figure 1
See Note 1
Figure 2
See Note 2
Modem
Shielded
Cable Assy.
2
1
Support
Bracket
See Note 1
Ground Lug
Rotated 90°

Advertisement

loading

Summary of Contents for Toro Network 8000

  • Page 1 However, when properly installed and grounded, the surge protection module includ- ed in this kit will provide the maximum surge protection possible for the Network 8000 communication modem. Installing the surge protection kit is relatively easy due to its modular design and plug-in wiring harness. To determine the tools and additional materials required to complete the installation, please read through the instructions completely prior to starting the installation procedure.
  • Page 2 In addition, the Less Than 12 ft. (3.6 m) ground wires should not be touching other wires, components or pedestal surfaces. © 1992 THE TORO COMPANY Irrigation Division P.O. Box 489 PRINTING DATE Riverside, California 92502 JULY 1992 FORM NO.