Table of Contents

Advertisement

Quick Links

INSTRUCTION MANUAL
Handy Controller Exclusive for SF4B / SF4B<V2> Series
SFB-HC
Ver.2.1
F U
N C
T I O
N
C A
N C
E L
E N
T E
R
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic SFB-HC

  • Page 1 INSTRUCTION MANUAL Handy Controller Exclusive for SF4B / SF4B<V2> Series SFB-HC Ver.2.1 T I O © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 2 (MEMO) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 3 Thank you for purchasing Panasonic Electric Works SUNX’s Handy Controller SFB-HC (Ver. 2.1) ex- clusive for SF4B / SF4B<V2> series. Please read both the instruction manual of this manual and SF4B / SF4B<V2> series or SF-C14EX carefully and thoroughly for the correct and optimum use of this device.
  • Page 4: Table Of Contents

    3-3-11 Setting Contents Monitoring Function ..............37 3-3-12 Override Setting Changing Function (Ver. 2.1 only) ........38 CHAPTER 4 TROUBLESHOOTING ..............39 CHAPTER 5 SPECIFICATIONS / DIMENSIONS ..........40 6SHFL¿FDWLRQV ......................40 Dimensions ......................40 © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 5: Chapter 1 Introduction

    In case this device does not perform properly, the operator should report this to the person in charge and stop the machine operation immediately. The machine must not be operated until FRUUHFW SHUIRUPDQFH RI WKLV GHYLFH KDV EHHQ FRQ¿UPHG © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 6 Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Maintenance Clean this device with a clean cloth. Do not use any volatile chemicals. Other Never reassemble or remodel this device. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 7: Chapter 2 General Outline

    Override setting changing function Part Descriptions Female connector Male connector Cable (0.5m) FUNCTION indicator × 9 (Green) FUNCTION switch FUNCTION Digital display (Red) - switch + switch CANCEL switch ENTER switch CANCEL ENTER © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 8: Connecting / Setting Procedures

    Then, inspect the SF4B / SF4B<V2> series. REFERENCE Refer to “Chapter 4 Maintenance” of the SF4B / SF4B<V2> series instruction manual for the details of the inspection of the SF4B / SF4B<V2> series. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 9 Then, inspect the SF4B / SF4B<V2> series. REFERENCE Refer to “Chapter 4 Maintenance” of the SF4B / SF4B<V2> series instruction manual for the details of the inspection of the SF4B / SF4B<V2> series. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 10: When Using In Combination With Application Expansion Unit Sf-C14Ex

    Then, inspect the SF4B / SF4B<V2> series. REFERENCE Refer to “Chapter 4 Maintenance” of the SF4B / SF4B<V2> series instruction manual for the details of the inspection of the SF4B / SF4B<V2> series. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 11 (The safety output 1 / 2 of SF-C14EX is also set to “OFF” while SF-C14EX has been used.) Once the setting is completed, turn OFF the power, remove this de- vice and then turn ON the power again. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 12: Chapter 3 Functions

    (YHQ LI WKH SRZHU LV WXUQHG 21 DJDLQ WKH ¿[HG EODQNLQJ IXQFWLRQ VWLOO VWD\V HIIHFWLYH :KHQ WKH ¿[HG EODQNLQJ IXQFWLRQ LV XVHG WKH UHFHLYHG OLJKW LQWHQVLW\ LQGLFDWRU RI SF4B / SF4B<V2> series is turned OFF regardless of the received light intensity. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 13: Floating Blanking Function

    C : Additional distance calculated from the size of the minimum sensing object of the SF4B / SF4B<V2> series (mm) However, the value of C cannot be under 0. C = 8 × (d - 14) d: Diameter of the minimum sensing object (mm) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 14: Auxiliary Output Switching Function

    (OSSD 1 / 2) is in ON sate, however, the auxiliary output becomes OFF since the SF4B / SF4B<V2> series has been detecting the obstacle. 3) The state of the auxiliary output remains the same even if the SF4B / SF4B<V2> series state changes. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 15: Emission Intensity Control Function

    ‡ Manual setting : Each beam channel can be set to “effective / ineffective” in the muting function. ON: The muting function is effective OFF: The muting function is ineffective © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 16: Interlock Setting Changing Function

    1. Allowable period of the response time: 100 to 600ms (unit of 10ms) The factory setting is 300ms. 2. “Effective / ineffective” of the external device monitor function can be selected. The factory setting is “effective.” © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 17: Protective Function

    Maximum continuous effective time set at the override function can be changed. The maximum continuous effective time can be set in the range of 60 to 600 sec. (in units of 10 sec.). The factory setting is 60 sec. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 18: Functional Descriptions

    (YHQ LI WKH SRZHU LV WXUQHG 21 DJDLQ WKH ¿[HG EODQNLQJ IXQFWLRQ VWLOO VWD\V HIIHFWLYH :KHQ WKH ¿[HG EODQNLQJ IXQFWLRQ LV XVHG WKH UHFHLYHG OLJKW LQWHQVLW\ LQGLFDWRU RI SF4B / SF4B<V2> series is turned OFF regardless of the received light intensity. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 19: Floating Blanking Function

    C : Additional distance calculated from the size of the minimum sensing object of the SF4B / SF4B<V2> series (mm) However, the value of C cannot be under 0. C = 8 × (d - 14) d: Diameter of the minimum sensing object (mm) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 20: Auxiliary Output Switching Function

    4) When using in combination with SF-C14EX, the muting function cannot be set on SF4B / SF4B<V2> series side. Thus, the state of the auxiliary output remains the same regardless of the SF4B / SF4B<V2> series state. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 21: Emission Intensity Control Function

    ‡ Manual setting : Each beam channel can be set to “effective / ineffective” in the muting function. ON: The muting function is effective OFF: The muting function is ineffective © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 22: Interlock Setting Changing Function

    It is recommended that the protecting function should be set to “effective” so as not to change the setting by the third person. 7DNH VXI¿FLHQW FDUH QRW WR IRUJHW WKH VHW SDVVZRUG ,Q FDVH \RX IRUJHW WKH SDVVZRUG please contact us. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 23: Initialization Function

    (Reading out the record of the latest 5 times is possible, however, only for setting beam channel.) 3-2-12 Override Setting Changing Function (Ver. 2.1 only) This function cannot be set when SF-C14EX is used. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 24: Function Setting (Operation Procedure)

    To “3-3-12 Override Setting Changing Function” “****” indicates the connection state of the system. “ ”: SF4B / SF4B<V2> series is used only. “ ”: SF-C14EX is used in combination. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 25 Complete inputting password for 1 unit Complete inputting password for 2 units Complete inputting password When using in combination with SF-C14EX Input password SF-C14EX key operation : ENTER : CANCEL Complete inputting password © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 26 (Ver. 2.1 only)” cannot be changed. CH3 (Sub sensor 2) CH2 (Sub sensor 1) ALL (All sensor) (*) CH1 (Main sensor) *: When the units are not in series connection, it is not indicated. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 27: Fixed Blanking Function

    Beam channel : CANCEL *: The functional setting for each beam channel is as follows. RQ  7KH ¿[HG EODQNLQJ IXQFWLRQ LV HIIHFWLYH R))  7KH ¿[HG EODQNLQJ IXQFWLRQ LV LQHIIHFWLYH © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 28: Floating Blanking Function

    CLR (Ineffective) : Serial beam channel mode Note: When “all sensors” is selected in the sensor selection, the setting of the floating blanking function on each SF4B / SF4B<V2> series should be identical. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 29: Auxiliary Output Switching Function

    2) When using with SF4B / SF4B<V2> series only, if the external device monitor function is not used, set the monitor set- ting to ineffective in “3-3-8 External Device Monitor Setting Changing Function.” © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 30: Emission Intensity Control Function

    SF4B-F  SF4B-F <V2> and SF4B-H  SF4B-H <V2> (72 to 96 beam chan- nels) and SF4B-A  SF4B-A <V2> (36 to 48 beam channels) (factory setting). SET (Effective) : The operating range is reduced by approx. 50%. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 31: Copy Function

    60 to 600 sec. (in units of 10 sec.) Notes: 1) The indication is on the main sensor (CH1) only. 2) When using in combination with SF-C14EX, it is not indicated. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 32: Muting Setting Changing Function

    (Note 3) Beam channel No. (Error) (NONC) The beam channel No. is given with 1, 2, 3 from the bottom. key operation : FUNCTION : ENTER Beam channel : CANCEL © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 33 “ALL” is selected. 3) It is not indicated when using with SF4B series. In addition, it is not indicated when using with SF-C14EX, either. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 34: Interlock Setting Changing Function

    Mode 2: Restart interlock function Mode 3: Ineffective Note: When using SF-C14EX, the display does not change even if ENTER key is pressed. (Mode 0, Start / Restart interlock function) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 35: External Device Monitor Setting Changing Function

    SET (Effective) : The external device monitor function is effective. (The factory setting is 300ms.) Note: When using SF-C14EX, the display does not change even if ENTER key is pressed. (The external device monitor: Effective) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 36: Protective Function

    Send (Ineffctive) To 9 10. To Sub dis- play function / Initialization function (Eeffctive) (Error) Input new Send password To 9 (Change password) Increase / decrease the No. with (Error) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 37: Initialization Function

    11. To Sub dis- play function / Setting con- (Error) tents moni- toring function (Main sensor) key operation : FUNCTION (Sub sensor 1) : ENTER : CANCEL (Sub sensor 2) © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 38: Setting Contents Monitoring Function

    : FUNCTION : ENTER : CANCEL (Model No.) (No. of beam channel) Notes: 1) The indication is on the main sensor (CH1) only. 2) When using SF-C14EX, this is not indicated. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 39: Override Setting Changing Function (Ver. 2.1 Only)

    SF4B / SF4B<V2> series. Notes: 1) The factory setting is 60 sec. 2) It is not indicated when using with SF4B series. In addition, it is not indicated when using with SF-C14EX, either. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 40: Chapter 4 Troubleshooting

    If this device does not work, press ENTER key or CANCEL key one minute after pressing ENTER key. If the device does not work correctly after checking the items above, please consult us. © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 41: Chapter 5 Specifications / Dimensions

    2) When using in combination with SF-C14EX, the setting cannot be changed. 3) When using with SF4B series, the setting cannot be changed. Dimensions (Unit: mm) 25.4 ø6 cable 0.5m long © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 42 First edition May 13, 2005 Second edition July 14, 2005 Third edition October 11, 2005 Fourth edition April 28, 2006 Fifth edition November 17, 2008 Sixth edition July 1, 2011 © Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V...
  • Page 43 3. DISCLAIMERS (1) Panasonic Electric Works SUNX's sole obligation and liability under this warranty is limited to the repair or re- placement, or refund of the purchase price, of a defective Product, at Panasonic Electric Works SUNX's option.
  • Page 44 Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0 US Headquarter: Panasonic Electric Works Corporation of America 629 Central Avenue New Providence, New Jersey 07974 USA Phone: +1-908-464-3550 MJE-SFBHC No.0024-49V © Panasonic Electric Works SUNX Co., Ltd. 2011...