Temperature light ring
This device is equipped with a temperature light ring
around the power button (Fig. 14).
After the measurement, the ring lights up red, depending
on the measured temperature.
-
When the temperature light ring lights up red,
the measured temperature is between 100.4°F /
38.0°C and 109.2°F / 42.9°C .
Transmit and display personal measurement results in
the app
Note: Your personal measurement data is only stored
and displayed in the Philips Avent uGrow app.
1
Start up the Philips Avent uGrow app, go to the
Temperature section and switch on Bluetooth on
your mobile device.
2
The Bluetooth symbol will light up on the display of
the thermometer to indicate it is connected to your
mobile device.
-
Once successfully connected, the measurement
results will be automatically transmitted to your mobile
device via Bluetooth. If you need more information
about transmitting measurement results to the app
please visit www.philips.com/earthermometer.
-
If the data transmission is successful, the
measurement results are displayed in the Philips
Avent uGrow app and will not be available in the
thermometer anymore.
-
The time and date of each measurement is shown in
the Philips Avent uGrow app.
Removing/inserting batteries
When the batteries are almost empty, the display shows
a flashing battery symbol and the text „bAtt' (Fig. 15).
When the battery low symbol appears on the display
(Fig. 4) or if the device does not function at all, replace
the batteries. The device works on 2x 1.5V AAA batteries.
Data will be lost when the batteries are completely
empty or are taken out of the thermometer.
1
Slide the battery cover down to open the battery
compartment and remove the empty batteries (Fig. 16).
2
Insert two new batteries in the battery compartment
according to the polarity indications ( + and - )
marked inside the compartment. Press down the
batteries until they click into place (Fig. 17).
3
Slide the battery cover back until it locks into place
(Fig. 18).
Setting the measurement unit
You can select either Fahrenheit (°F) or Celsius (°C) for
measuring temperature.
1
Switch on the device.
2
Press and hold the °F / °C selection button for
3 seconds to change the measurement unit (Fig. 19).
Cleaning and storage
Caution: Do not expose the device to extreme temperatures
(below -4 °F/-20 °C or over 140 °F/60 °C), extreme levels of
humidity (below 15%RH or over 85%RH), direct sunlight or
shock. This may result in inaccurate measurements.
For hygienic reasons, the device should be cleaned
after each use.
1
Moisten the cotton swab with a few drops of alcohol
and wipe the surface of the infrared sensor gently
with the swab (Fig. 20).
2
Immediately wipe the surface dry with a clean cotton
swab.
3
Use a soft dry cloth to clean the body of the device
(Fig. 21).
4 Store the device in a clean, dry place at room
temperature.
This device has no other user-serviceable parts.
For assistance call 1-800-54-AVENT.
Calibration
The device has been calibrated when it was
manufactured. If the device is used according to the
instructions, recalibration is not required. If you question
the accuracy of the measurement at any time,
call 1-800-54-AVENT for assistance.
Accessories
Philips accessories may be purchased at a store near
you, or on our website www.philips.com/store.
Specifications
Power supply
2 x 1.5V AAA non-rechargeable
alkaline batteries
Temperature
90.3°F - 109.2°F / 32.4°C - 42.9°C
measuring
range
In-ear
± 0.4°F (± 0.2
C) within the range of
°
measurement
90.3°F - 109.2°F / 32.4
°
C - 42.9
°
C
accuracy
5.3" (L) x 1.5" (W) x 1.1" (H) / 134 (L) x
Dimensions
37 (W) x 27 (D) mm
Weight
About 0.12 lb / 54.6 g (without
battery)
50.0°F - 104.0°F (10.0
C - 40.0
C) with
Operating
°
°
a relative humidity of 15% - 85%, 86
conditions
kPa to 106 kPa
Storage and
-4°F - 140°F (-20
°
C - 60
°
C) with a
transport
relative humidity of 15% - 85%, 86 kPa
conditions
to 106 kPa
2 years
Service life
Disposal
-
Battery must be removed from the device before
discarding.
-
Dispose of batteries properly. Do not incinerate.
Batteries may explode if overheated.
-
Do not wrap in metal or aluminum foil. Tape the
waste battery terminals before discarding.
-
It is suggested that you contact your local town or
city to determine proper battery redemption site(s) in
your area.
Troubleshooting
This chapter summarizes the most common problems
you could encounter with the device. If you are unable
to solve the problem with the information below, visit
www.philips.com/support for a list of frequently asked
questions or call 1-800-54-AVENT for assistance.
Problem
Possible cause Solution
The device
The batteries
Replace the
does not
are empty.
batteries.
respond
or resets
automatically
when I pull out
the battery strip.
The poles of the
Remove the
batteries point
batteries and
in the wrong
reinsert them
direction.
properly.
The batteries
Remove the
are not making
batteries and reinsert
proper contact.
them properly.
The displays
The measured
Follow the
shows Lo or Hi
temperature
instructions in
is lower than
the user manual
90.3°F / 32.4°C
for proper
or higher than
measurement.
109.2°F / 42.9°C.
Use the
Temperature
thermometer in the
is out of
range of operating
temperature
conditions.
measuring
range.
The
Clean the infrared
The infrared
thermometer
sensor with a cotton
sensor is not
seems to be
swab (see 'Cleaning
clean enough.
inaccurate
and storage').
or the
measurement
results seem
questionable.
You are not
Ensure that the
measuring
thermometer is
temperature
pointed correctly
in the correct
towards the eardrum
way.
(Fig. 10). An incorrect
measurement
position (Fig. 11) might
lead to incorrect
measurement results.
Make sure that you
have read the user
manual and know
how to use the
device properly.
Use your
Your room
thermometer at
temperature is
room temperatures
too low or too
between 50.0°F and
high.
104.0°F (10.0°C and
40.0°C).
You are using
The device is only
the device
intended for indoor
outdoors.
use.
Problem
Possible cause Solution
Put the device on
You have held
the table in the
the device in
room where the
your hand too
measurement is
long.
taking place and let
it cool down first.
The batteries
The battery
Replace the empty
are empty.
symbol flashes
batteries with two
on the display
new ones.
or the display
is blank.
The display
Remove and replace
Self-test error
shows Err0
the batteries. If the
error persists, call
1-800-54-AVENT
for assistance.
Stabilization
The display
Wait 30 minutes and
error
shows Err2
measure again.
The display
Battery level
Replace the empty
shows Err3
low
batteries with new
ones.
Assistance
For assistance, visit our website:
www.philips.com/support or call toll free
1-800-54-AVENT Online information is available
24 hours a day, 7 days a week.
Full Two-Year Warranty
Philips North America LLC (USA) and Philips Electronics
Ltd (CANADA) warrant each new Philips product, Model
SCH740, against defects in materials or workmanship
for a period of two years from the date of purchase and
agrees to repair or replace any defective product without
charge.
IMPORTANT: This warranty does not cover damage
resulting from accident, misuse or abuse, lack of
reasonable care, the affixing of any attachment not
provided with the product or loss
of parts or subjecting the product to any but the specified
battery.*
NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES.
In order to obtain warranty service, simply go to
www.philips.com/support or call toll-free
1-800-54-AVENT. It is suggested that for your protection
you return shipments of product by insured mail,
insurance prepaid. Damage occurring during shipment is
not covered by this warranty.
NOTE: No other warranty, written or oral, is authorized by
Philips North America LLC.
This warranty gives you specific legal rights, and you
may also have other rights which vary from state to state.
Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above
exclusion and limitations may not apply to you.
* Read enclosed instructions carefully.

Advertisement

loading