CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
1. Remove the 2 screw covers in the front panel.
2. Removr 2 fixed screws.
3. Pull the open panel at " A " toward you.
Remove a fixed screw.
A

DISASSEMBLING PROCEDURE

FOR INDOOR UNIT MODEL AY-A079E/AY-A099E
A
4. Close the open panel softly, and then press " B " and
" C " of it securely.
Remove the front panel ass'y as to lift up.
B
5. Loose a cord clamp screw and take it out.
6. Loose 3 screws on the terminal board and take out
the unit-to-unit cord from it.