DS210 Indoor Motion Sensor – PIR
WARNING: Read and understand all instructions and
warnings for this product. In addition, read and follow all
instructions and warnings provided with the DS100 JobSite Security
Portable Alarm System.
CAUTION: DANGER OF EXPLOSION, INJURY, OR FIRE.
Carefully follow all instructions and warnings on the battery label and
package.
• Never use a damaged or worn out battery.
• Discharged batteries should be replaced only with type CR-123 3.0
Volt Lithium batteries.
• Do not use re-chargeable batteries or attempt to charge batteries.
• Carefully remove the old, discharged battery.
• Do not attempt to open.
• Do not peel the label from the battery.
• Never dispose of a battery in a fire.
• Dispose of used batteries in accordance with local regulations.
• Recycle batteries.
• Always insert batteries correctly with regard to polarity (+ and -)
marked on the battery and the equipment.
• When installing the battery, do not use excessive force. If the
battery does not fit, check to make sure that it matches the polarity
markings.
• Never expose the battery terminals to any other metal object. This
can short circuit the battery.
• Avoid exposure to temperature extremes.
• When not in use, store the battery in a cool, dark, dry place.
• Keep batteries out of reach of children.
CAUTION:
POTENTIAL EQUIPMENT
FAILURE. Do not use near water. Damage to the equipment may
occur. Equipment shall not be exposed to liquids.
FCC REGULATORY STATEMENT (FCC: HCQ3B6ETICRM)
• This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) the device must accept any
interference received, including interference that may cause unde-
sired operation.
INDUSTRY CANADA (IC: 2309A-ETICRM)
• NOTICE: This equipment meets the applicable Industry Canada
Terminal Equipment Technical Specifications. This is confirmed
by the registration number. The abbreviation, IC, before the reg-
istration number signifies that registration was performed based
on a Declaration of Conformity indicating that Industry Canada
technical specifications were met. It does not imply that Industry
Canada approved the equipment.
Components (Fig. 1)
A. Antenna
B. Test Mode Reed Switch
C. Reset Button
Product Function (Fig. 2)
The DS210 Indoor Motion Sensor – PIR (Passive Infrared) is a low-
current motion detector highly sensitive to moving heat sources. This
sensor provides a 50' (15.24m) range of protection with advanced
digital scanning to recognize human movements and size to help
prevent false alarms.
NOTE: The DS210 signals an unsecured condition when motion is
detected by the sensor. Once an unsecured condition is signaled,
further unsecured conditions are inhibited until no motion is sensed for
a period of more than 90 seconds. This feature is designed to conserve
battery life.
Once activated, this device will work exclusively with the assigned
DS100 JobSite Security Portable Alarm System.
SITELOCK LLC, 626 Hanover Pike, Hampstead, MD 21074
MALFUNCTION
D. Tamper
E. Battery
FIG. 1
E
B
CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR
FAILURE. Do not touch the electronic components inside
the device, except the reset button and battery.
FIG. 3
OR
• The DS210 features 900 MHz spread spectrum communication
with the Base Unit allowing for a range of up to 2000' (610m).
• The DS210 features a tamper (D) that notifies the system when
the sensor cover is removed.
• The DS220 device uses a CR-123 3.0V Lithium battery (E) for
long life.
• The reset button (C) allows the Indoor Motion Sensor – PIR to
be registered to any D
easy set up.
NOTE: Metal objects blocking radio frequency (RF) transmission can
affect the range of the sensor
Prevention of False Alarms
The majority of alarms that occur are false. These situations happen
every day due to user error, incorrect installation or improper mainte-
nance of the system. False alarms will limit the responsiveness to the
system, and become a general inconvenience. As the number of
false alarms increases, authorities have become less apt to respond
to alarm systems due to this problem. Many of these situations can be
avoided by following some very simple practices.
• Ensure all users are properly trained on the operation of the
system.
• Always turn off the system with the Key Chain Remote Control
before entering protected area.
• Lock all protected doors, windows or any other asset attached to
a sensor.
• Check that motion detectors are not obstructed. Do not allow
sources of heat or sound in range of the motion or vibration
sensors.
• Check that premises are cleared and assets secured before setting
the system.
(OCT04)
Form No. 626134-01
FIG. 2
A
C
D
FIG. 4
WALT JobSite Security System with
E
DS210
Copyright © 2004 D
TOP VIEW
SIDE
VIEW
MOUNTING
TAPE
OR
HOOK &
LOOP
WALT
E

Advertisement

loading

Summary of Contents for DeWalt DS210

  • Page 1 Base Unit allowing for a range of up to 2000' (610m). cause harmful interference, and (2) the device must accept any • The DS210 features a tamper (D) that notifies the system when interference received, including interference that may cause unde- the sensor cover is removed.
  • Page 2 Do not about .25" (6 mm) at the tab on the top of the unit. Pry downward place the DS210 looking at windows. Don’t place it near heating on the handle of the screwdriver until the latch holding the cover or cooling sources, like heater ducts or air conditioners, which to the housing base releases (Fig.
  • Page 3 WALT JobSite Security Portable Alarm System is warranted for one year from date of purchase. We will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, visit www.dewalt.com or call 1-800-4-D WALT (1-800-433-9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others.
  • Page 4 Fonction du produit (fig. 2) placer près d’objets pouvant chauffer rapidement à la lumière solaire. Ne pas placer le DS210 face à une fenêtre. Ne pas dis- Le Détecteur de mouvements intérieur DS210 (PIR : à infrarouge poser l’appareil près d’une source de chaleur ou de refroidisse- passif) est un détecteur de mouvements à...
  • Page 5: Installation Murale

    Installation murale • Las pilas desechadas deberían sólo ser cambiadas por pilas de • Il y a plusieurs options pour installer le DS210. Le détecteur de litio de 3,0 voltios tipo CR-123. mouvements intérieur est muni de deux trous sur l’arrière pour •...
  • Page 6 • El DS210 funciona mejor cuando las áreas a proteger son cer- formidad indicando que las especificaciones técnicas del cadas por barreras sólidas. Las paredes y los pisos son buenos Ministerio de Industria de Canadá...
  • Page 7: Montaje

    Elegir Despej. Montaje d. Ingrese el código maestro. • Existen varias opciones de montaje para el DS210. El sensor de e. Seleccione OK. movimiento interior tiene dos orificios de montaje en la parte de Registro del dispositivo atrás del sensor para una instalación más sencilla con dos tornil-...
  • Page 8 Repararemos, sin costo, cualquier defecto debido a fallas en materi- ales o mano de obra. Para mayor información sobre reparaciones bajo garantía, visite www.dewalt.com o llame al 1-800-4-D WALT (1-800-433-9258). Esta garantía no aplica a accesorios o a daños causados por reparaciones realizadas o intentadas por terceros.