It is important that the position of the ADTS 405 in relation to the UUT is known. An altitude
correction must be made to allow for the difference in height between the reference level, indicated
on the mimic panel, and the UUT. The Reference section contains details of altitude correction
(SETUP, ALTITUDE).
WARNING
OBSERVE THE APPROPRIATE SAFETY INSTRUCTIONS AND PROCEDURES
DETAILED IN THE AIRCRAFT MAINTENANCE MANUAL AND COMPONENT MAINTENANCE
MANUALS.
Corrected altitude output = true altitude output increased by height difference
2.4.2 405F Flightline version
It is important that the position of the ADTS 405F in relation to the aircraft altitude sensors is
known. An altitude correction must be made to allow for the difference in height between the
reference level and the aircraft's altitude sensors. The Reference section contains details of altitude
correction (SETUP ALTITUDE).
10 | ADTS 405 Mk2 Instruction Manual-English
Table 2-2: DC Input Connector
Cable Colour
1
Grey
2
White
EARTH
Green
rack-mounted ADTS 405R
ADTS panel marked reference level
Figure 2-2: ADTS 405R Altitude Reference
Function
+ 28V
0V Return
Protective Ground
requires negative
altitude correction value
UUT
entered when below ADTS
UUT reference level