Honeywell LTE-X series Installation And Setup Manual

Honeywell LTE-X series Installation And Setup Manual

Sends alarms and messages to alarmnet

Advertisement

L
T
E
-
X
S
L
T
E
-
X
S
L
T
E
-
X
V
L
T
E
-
X
V
L
T
E
-
X
A
L
T
E
-
X
A
L
T
E
-
X
C
L
T
E
-
X
C
I
n
s
t
a
l
l
a
t
i
o
n
I
n
s
t
a
l
l
a
t
i
o
n
800-23340 10/17 Rev B
e
r
i
e
s
C
o
e
r
i
e
s
C
o
a
n
d
S
e
t
u
p
a
n
d
S
e
t
u
p
m
m
u
n
i
c
m
m
u
n
i
c
G
u
i
d
e
G
u
i
d
e
a
t
o
r
s
a
t
o
r
s

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell LTE-X series

  • Page 1 800-23340 10/17 Rev B...
  • Page 2: Table Of Contents

    Contents General Information ..............................1 Features ................................1 Supervision and Fault Detection ......................... 1 Specifications ................................ 2 Data Encryption ..............................2 Remote Services Features ........................... 2 Testing the System .............................. 2 Compatibility ................................ 2 Compliance ................................3 Mount and Wire the Module ............................ 3 Select a Mounting Location ..........................
  • Page 3: General Information

    LTE-X Series Installation and Setup Guide General Information The LTE-X Series Communicator, herein referred to as the communicator, easily connects to your security system's control panel and sends alarms and messages to AlarmNet for subsequent transfer to the central monitoring station. It can be mounted directly on the control panel or remotely.
  • Page 4: Specifications

    Program/Validation/Validation-List/AES and search for “Certificate number 979. Remote Services Features Remote Access has not been evaluated by UL. Honeywell offers secure web based services that enable users to remotely monitor and control their security system. These web services enable users to: •...
  • Page 5: Compliance

    LTE-X Series Installation and Setup Guide Compliance This device has been tested by ETL to meet the following standards: • UL985 – Residential Fire • Canadian ULC Compliance • UL1023 – Residential Burg Mount and Wire the Module Select a Mounting Location When choosing a suitable mounting location, understand that it must be mounted indoors, and for best signal strength it should be mounted vertically.
  • Page 6: Mounting The Module On The Control Panel

    LTE-X Series Installation and Setup Guide Mounting the Module on the Control Panel Ensure power to the control panel (both AC and battery) is off, then remove the knockout on the top right of the control panel cabinet. Open the communicator cover. Remove the Hole Cap attached to the plastic (trim as necessary), and snap it into the top opening of the enclosure.
  • Page 7: Programming The Module

    LTE-X Series Installation and Setup Guide Connect the ECP cable to the communicator circuit board. When mounting the communicator off the cabinet, the length of the supplied ECP cable will have to be spliced to a four-wire extender cable. Ensure the splices are located within the communicator's enclosure.
  • Page 8: Using The Alarmnet 360 Website

    LTE-X Series Installation and Setup Guide Using the AlarmNet 360 Website To program the communicator via the website (if you are already signed up for this service), go to: Alarmnet360.com (https://services.alarmnet.com/AlarmNet360/AlarmNetDirectV) If you are not signed up for this service, click on “Dealer Sign-Up" and follow the instructions. Log in and follow the on- screen prompts.
  • Page 9: Programming Conventions

    LTE-X Series Installation and Setup Guide Programming Conventions • Programming is accomplished by answering a series of prompts. Most prompts require only a [Y]es or [N]o response, while others require a numerical response (ID numbers, etc.). • The current value is displayed on the second line in parentheses ( ). A "?" indicates an invalid entry.
  • Page 10 LTE-X Series Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION [Y], [N] If a password has already been assigned, this prompt Change Password? appears after pressing [N] at the "Program Device?" (Y/N)_ prompt. Press [Y] if you want to change the password.
  • Page 11 LTE-X Series Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION [Y], [N] Applicable only if the control panel supports Central En. 2nd CS Y/N Station #1 and #2 Category Enable reporting for the communicator (or LRR) device (e.g., VISTA-128BPT, VISTA-250BPT, etc.).
  • Page 12: Ecp Status Codes

    LTE-X Series Installation and Setup Guide PROMPTS ENTRY OPTIONS DESCRIPTION [Y] = review Reviewing Programming Mode Entries Review? Y/N [N] = exit To review the programming options (to ensure that the correct entries have been made), press [Y]. The programming prompts are displayed again. Use the up/down arrow keys to scroll through the program fields without changing any of the values.
  • Page 13: Setting Factory Defaults

    LTE-X Series Installation and Setup Guide Setting Factory Defaults To reset the programming options to factory-default values, press [ESC] at the "Exit Prog Mode?" prompt. Press [Y] to reset factory default values. Set Default? Y/N_ Press [N] to cancel this function.
  • Page 14: Remote Services (Total Connect)

    LTE-X Series Installation and Setup Guide Remote Services (Total Connect) The dealer/installer will set up the customer account and define the events to be notified of. At the AlarmNet 360 website, refer to the online "AlarmNet 360 User Guide" for information on configuring the hardware and creating a Total Connect web account for the customer.
  • Page 15: Registering Using The 7720P Programming Tool

    LTE-X Series Installation and Setup Guide Registering Using the 7720P Programming Tool The interactive registration feature allows the installer to register the communicator through a series of keyboard commands on the 7720P Programming Tool. This method of registration lets the installer monitor the registration process.
  • Page 16: Diagnostic Commands

    LTE-X Series Installation and Setup Guide Diagnostic Commands The 7720P programming tool can be used to view the connectivity settings and options. To invoke diagnostic commands; such as [A], [B], [C], etc., the [shift] key MUST used. For example, [shift] + [A] displays the software revision.
  • Page 17: Lte Status Displays

    LTE-X Series Installation and Setup Guide LTE Status Displays Operating with Cellular service Cellular Status Display Screen 1 SigQuaI RAT – Radio Access Technology. – LTE or 3G LTE/3G ***** SigQual – Signal Quality (1-5 “*’) REG – Registration status where “x” can be: N –...
  • Page 18 LTE-X Series Installation and Setup Guide Location Display for LTE Cntry Netw Cntry – Country Code xxxxx Netw – Network Code TAC – Tracking area code Press the [space] key to get to the next screen. Press the [backspace] key to go to the previous field.
  • Page 19 LTE-X Series Installation and Setup Guide ECP Mode Displays the mode of operation and system fault status. Flt – Represents communicator faults: OK = Normal, No fault. G = No network connectivity over cellular network and fault time has expired.
  • Page 20: Central Station Messages

    Advanced Encryption Standard Cyclic Redundancy Check used to confirm validity of MAC ID. Enhanced Console Protocol, is a proprietary bus used in Honeywell control panels to communicate with keypads and peripheral devices. It uses four wires; power, ground, data in, data out.
  • Page 21 LTE-X Series Installation and Setup Guide – NOTES – – 19 –...
  • Page 22 LTE-X Series Installation and Setup Guide – NOTES – – 20 –...
  • Page 23: Led And Wiring Information

    LED and Wiring Information DESCRIPTION Module is NOT registered with AlarmNet. Module is registered with AlarmNet. (green) FAST BLINK Download session with Compass in progress. SLOW BLINK In unison with yellow LED – Registration in progress. Message transmission pending. TX/RX QUICK (yellow) PERIODIC...
  • Page 24 ERP and EIRP power limits as specified in FCC Parts 22H, 24E and 27, or ISED RSS-130, RSS-132, RSS-133, and RSS-139. Support and Warranty For online support information, please go to: https://mywebtech.honeywell.com/ For the latest warranty information, go to: www.honeywell.com/security/hsc/resources/wa For patent information, see www.honeywell.com/patents...

This manual is also suitable for:

Lte-xvLte-xaLte-xc

Table of Contents