Siemens SIMATIC PC BI45 Technical Description
Siemens SIMATIC PC BI45 Technical Description

Siemens SIMATIC PC BI45 Technical Description

Pc bi45/fi45 pii

Advertisement

Quick Links

SIMATIC
PC BI45/FI45 PII
Technical Description
07/99
C79000-G7076-C794
Release 03
Contents
System Unit
Motherboard
Keyboard Controller
Direct Key Module
Bus Board
Front Adapter Module
Monitoring Module
Touch Screen
Display
Hard Disk Drive
Floppy Disk Drive
CD-ROM Drive
Power Supply
Connecting Cables
Appendix
ESD Guidelines
Index
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC PC BI45

  • Page 1 Contents System Unit Motherboard SIMATIC Keyboard Controller Direct Key Module PC BI45/FI45 PII Bus Board Front Adapter Module Technical Description Monitoring Module Touch Screen Display Hard Disk Drive Floppy Disk Drive CD-ROM Drive Power Supply Connecting Cables Appendix ESD Guidelines Index 07/99 C79000-G7076-C794...
  • Page 2 Trademarks SIMATIC , SIMATIC HMI and SIMATIC NET are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners.
  • Page 3: Table Of Contents

    ..........2-12 SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 4 ........Connector Assignment of Keyboard Controller ..... . 3-11 SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 5 ..........7-14 SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 6 ............. Index-1 SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 7: System Unit

    1.4.17 Removing and Installing the Touch Pad for the FI45 1-31 1.4.18 Removing and Installing the Front Adapter Module for 1-31 the FI45 Connecting MPI/DP Interface 1-32 Point-to-Point Connections 1-33 Error Diagnostics 1-35 SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 8: Technical Specifications

    10 A 0.5 A 0.5 A 0.05 A Noise emission < 50 dB (A) to DIN 45635 Degree of protection for SIMATIC PC BI45 IP20 Degree of protection for SIMATIC PC FI45 IP65, front (with drive cover closed) Safety Protection class...
  • Page 9: Hard Disk Drive

    1024 x 768 (XGA) Colors 65536 (from 162.144) Contrast 100:1 Brightness 150 cd/m Response time 30/50 ms (t rise fall Permitted fault locations high/low level: < 12/25 spots green high level: < 5 spots SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 10 *1 Maximum of 150 W in total, with +5V and +3.3V the sum of 100W must not be exceeded. +12V can be loaded with 11A for a maximum of 10 seconds. *2 Optically isolated within the safety extra-low voltage circuit (SELV) SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 11: Maximum Dimensions Of Expansion Modules

    System Unit Maximum Dimensions of Expansion Modules Information on The SIMATIC PC BI45/FI45 is designed for modules according to AT/PCI Modules specifications. The size of the modules should not exceed the dimensions indicated. If the given height is exceeded, this may cause contacting problems, functional disorders, or difficulties with installation.
  • Page 12 Large PCI modules have to be equipped with a so-called extender (usually Large PCI Modules included with large PCI modules) which serves to guide them along the rails of the ventilator case. The extender guides large PCI modules along the rails of ISA modules. SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 13: Power Requirements Of The Components (Maximum Values)

    0.05 A module Restrictions on Due to thermal stress, the maximum capacity of the power supply is Power Supply restricted to: Power supply Restriction Standard power supply (220 W) maximum load 150 W SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 14: Removing And Installing Components

    Risk of damage to the unit! Note that only qualified personnel should be allowed to work on the open unit, so the warranty on the device is not affected. Authorized SIEMENS maintenance and repair centers offer you a specialist maintenance service.
  • Page 15 Touch components and modules only on their edges. Above all, do not touch the connecting pins and printed conductors. Do not operate the PC with the cover open. Tools Use a suitable crosstip or TORX screwdriver to remove or install components. SIMATIC PC BI45/FI45 PII, Technical Description C79000-G7076-C794-03...
  • Page 16: Opening And Closing The System Unit Of The Bi45

    Pull out the power supply connector. Remove the PC from its support. Release the seven screws on the cover of the unit. Fastening screws Cover of the unit Figure 1-5 Opening the System Unit of the BI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-10 C79000-G7076-C794-03...
  • Page 17 – Bus board – Fan – Processor – RAM memory module(s) Motherboard RAM memory module Processor board Power supply Floppy disk drive and CD-ROM drive Figure 1-6 Function Units when the BI45 is Opened SIMATIC PC BI45/FI45 PII, Technical Description 1-11 C79000-G7076-C794-03...
  • Page 18: Lowering The Fi45 System Box Away From The Front Panel

    Now lower the system box down completely. A wire holds the system box in place at a 90 angle. Figure 1-7 Lowering the System Unit of the FI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-12 C79000-G7076-C794-03...
  • Page 19: Keyboard Controller

    – Front adapter module – Touch pad controller module Inverter module LC display Keyboard controller Touch pad controller module Front adapter module Figure 1-8 Function Units in the Front Panel of the FI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-13 C79000-G7076-C794-03...
  • Page 20: Removing The System Box Of The Fi45 From The Front Panel

    Lift the system box upwards and out so that the hinge is released from its latched position; then pull the system unit further away from the front. The system unit is now isolated from the front unit. Figure 1-9 Removing the System Unit of the FI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-14 C79000-G7076-C794-03...
  • Page 21: Opening And Closing The System Unit Of The Fi45

    Remove the system box from the front panel as described in Section 1.4.3. Release the seven screws on the cover of the unit. Fastening screws Partition plate Figure 1-10 Opening the System Unit of the FI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-15 C79000-G7076-C794-03...
  • Page 22: Bus Board

    – Bus board – Fan – Processor – RAM memory module(s) RAM memory module Motherboard Bus board Processor CD-ROM drive Power supply Floppy disk drive Figure 1-11 Function Units when the FI45 is Opened SIMATIC PC BI45/FI45 PII, Technical Description 1-16 C79000-G7076-C794-03...
  • Page 23: Removing And Installing Expansion Modules

    When you bend the notched spring clips inwards a little, the snap-in lockings can be released. Grip the crossbeam, push it approximately 1cm to the left, and then lift it out with the the module retainers. SIMATIC PC BI45/FI45 PII, Technical Description 1-17 C79000-G7076-C794-03...
  • Page 24 Detach the part of the sliding element which juts out by scratching a notch in the top of the sliding element with a knife and then bending it over to break it off. SIMATIC PC BI45/FI45 PII, Technical Description 1-18 C79000-G7076-C794-03...
  • Page 25: Removing And Installing The Power Supply Unit

    Supply voltage selection switch On/off switch Power supply Power supply connector (input) connector (output) Figure 1-13 Connecting the Supply Voltage SIMATIC PC BI45/FI45 PII, Technical Description 1-19 C79000-G7076-C794-03...
  • Page 26 You must remove the power supply connector before changing the supply voltage. Operating a power supply unit set to 115V in conjunction with a 230V network may cause serious damage to the PC. SIMATIC PC BI45/FI45 PII, Technical Description 1-20 C79000-G7076-C794-03...
  • Page 27: Removing And Installing The Bus Board

    Take out the fan and the metal plate to which the guide rails are attached. Detach the plate with the guide rails by releasing the four plastic rivets. To install the fan, proceed in reverse order. SIMATIC PC BI45/FI45 PII, Technical Description 1-21 C79000-G7076-C794-03...
  • Page 28: Removing And Installing A Floppy Disk Drive Or Cd-Rom Drive For The Bi45

    The CD-ROM drive is fastened to the support with three screws. Release the screws and pull the drive out of the support. To install the drives, proceed in reverse order. SIMATIC PC BI45/FI45 PII, Technical Description 1-22 C79000-G7076-C794-03...
  • Page 29 This is necessary if the unit is installed with the network connection at the top. The floppy disk drive may not be operated with the opening for the diskettes face up or face down. SIMATIC PC BI45/FI45 PII, Technical Description 1-23 C79000-G7076-C794-03...
  • Page 30: Removing And Installing A Floppy Disk Drive Or Cd-Rom Drive For The Fi45

    The CD-ROM drive is fastened to the support with two screws. Release the screws and pull the drive out of the support. To install the drives, proceed in reverse order. SIMATIC PC BI45/FI45 PII, Technical Description 1-24 C79000-G7076-C794-03...
  • Page 31 System Unit Fastening screws for floppy disk drive Fastening screws for CD-ROM drive Figure 1-15 Floppy Disk/CD-ROM Drive Support for the FI45 SIMATIC PC BI45/FI45 PII, Technical Description 1-25 C79000-G7076-C794-03...
  • Page 32: Removing And Installing The Hard Disk Of The Bi45/Fi45

    Take the hard disk out out of the support. To install the drive, proceed in reverse order. Hard disk support Fastening screws for hard disk support Figure 1-16Removing the Hard Disk Support SIMATIC PC BI45/FI45 PII, Technical Description 1-26 C79000-G7076-C794-03...
  • Page 33 System Unit Hard disk support Hard disk drive Fastening screws Figure 1-17 Removing the Hard Disk Drive from the Support SIMATIC PC BI45/FI45 PII, Technical Description 1-27 C79000-G7076-C794-03...
  • Page 34: Removing And Installing The Motherboard

    The motherboard is fastened to the side of the system unit with 10 hexagonal socket screws. Undo these socket screws and remove the motherboard. To install the motherboard, proceed in reverse order. Motherboard Fastening screws Hexagonal socket screws Figure 1-18 Removing the Motherboard SIMATIC PC BI45/FI45 PII, Technical Description 1-28 C79000-G7076-C794-03...
  • Page 35: Removing And Installing The Membrane Keyboard Or Front Components Of The Fi45

    Unplug the 40-pin connector from the front adapter module and disconnect the interface cable carefully from the display. Remove the membrane keyboard and the front components mounted on it. To install the membrane keyboard, proceed in reverse order. SIMATIC PC BI45/FI45 PII, Technical Description 1-29 C79000-G7076-C794-03...
  • Page 36: Removing And Installing The Keyboard Controller For The Fi45

    Remove the rivets, by pressing the pin out from behind. To install the inverter module, proceed in reverse order. Caution When installing the module, do not forget to place the insulating foil between the inverter module and the metal plate. SIMATIC PC BI45/FI45 PII, Technical Description 1-30 C79000-G7076-C794-03...
  • Page 37: Removing And Installing The Display For The Fi45

    Before you unplug all the other connectors, write down their previous connections. Release the three screws; then you can remove the front adapter module. To install the front adapter module, proceed in reverse order. SIMATIC PC BI45/FI45 PII, Technical Description 1-31 C79000-G7076-C794-03...
  • Page 38: Connecting The Mpi/Dp Interface

    9.6 Kbps up to 1.5 Mbps. Note For further information on configuring a PROFIBUS-DP network please refer to the “S7-300 Hardware Manual,” order no.: 6ES7030-0AA00-8AA0. *) Optically isolated within SELV circuit SIMATIC PC BI45/FI45 PII, Technical Description 1-32 C79000-G7076-C794-03...
  • Page 39: Point-To-Point Connections

    1000 m (3300 ft.). The AS511 protocol (only one transmitter at a time) was used for testing. Note The contaminating field of the interference source decreases exponentially with the distance. SIMATIC PC BI45/FI45 PII, Technical Description 1-33 C79000-G7076-C794-03...
  • Page 40 1000 m (3300 ft), the receiving diode is connected to ground (reference) via Distances of up to the connecting cable. Cables of various lengths are available under the Order 1000 m (3300 ft.) No. 6ES5 734-2xxx0 (xxx stands for the length in meters). SIMATIC PC BI45/FI45 PII, Technical Description 1-34 C79000-G7076-C794-03...
  • Page 41: Error Diagnostics

    PS/2 port has been disabled in Check SETUP settings SETUP Mouse pointer moving erratically Trackball dirty Clean trackball and housing Drive cover cannot be opened Filter cap not properly fixed Push filter cap in proper position SIMATIC PC BI45/FI45 PII, Technical Description 1-35 C79000-G7076-C794-03...
  • Page 42 System Unit SIMATIC PC BI45/FI45 PII, Technical Description 1-36 C79000-G7076-C794-03...

This manual is also suitable for:

Simatic pc fi45